A Comparison of physical and dosimetric properties of lung substitute materials

被引:26
作者
Chang, Kwo-Ping [1 ,2 ]
Hung, Shang-Ho [1 ,2 ]
Chie, Yu-Huang [3 ]
Shiau, An-Cheng [4 ]
Huang, Ruey-Jing [1 ,2 ,5 ]
机构
[1] Tzu Chi Coll Technol, Inst Radiol Sci, Hualien, Taiwan
[2] Tzu Chi Coll Technol, Dept Radiol Technol, Hualien, Taiwan
[3] Mennonite Christian Hosp, Dept Radiat Therapy, Hualien, Taiwan
[4] Far Eastern Mem Hosp, Dept Radiat Therapy, New Taipei City, Taiwan
[5] Hualien Armed Forces Gen Hosp, Dept Radiol, Xincheng Township, Taiwan
关键词
cork; lung substitute; physical properties; dosimetry; Monte Carlo simulation; MONTE-CARLO; PHOTON; RADIOTHERAPY; DENSITY; TUMORS; COMPUTATION; ENERGY; SYSTEM; BEAM;
D O I
10.1118/1.3694097
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The need for an accurate estimate of absorbed doses within and around irradiated thorax tissues necessitates the use of carefully selected materials from which phantoms are constructed. A lung substitute is more difficult to establish mostly due to its low physical density. Although many researchers have used cork as a lung substitute, very little research data address cork's characteristics to determine which type of cork is optimal as a substitute for lung tissue. Methods: Natural cork, composition cork, rubber cork, ATOM, RANDO, and a reference lung material (ICRU-44 lung tissue) were investigated to establish comparisons of physical properties. Following the determination of the respective physical properties, the dose distributions from 6 MV photon beams in water/lung substitute/water phantoms were assessed using the Monte Carlo method. Physical and electron densities affecting the dose distributions through lung tissues in different field size conditions were investigated Results: The physical properties (physical density, electronic density, and effective atomic number) of the composition cork are the most similar to those of the ICRU-44 lung, and the CT number of the composition cork is very similar to that of humans aged 30-60. PDD of the composition cork and the RANDO phantom are the most comparable to that of ICRU-44 lung in 1 x 1 cm2 field size due to the combined properties of physical density (PD) and electron density per gram (EDG) of the studied lung materials. PD and EDG affect the lung dose primarily in small field size. The effects of PD are minimal in large fields, having a more rapid lateral electron equilibrium. EDG dominates PDD pattern in lung material when large fields are applied. Combined effects of PD and EDG are nonlinear for all field sizes. Conclusions: The composition cork is the preferred lung substitute based on physical and dosimetric properties. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694097]
引用
收藏
页码:2013 / 2020
页数:8
相关论文
共 29 条
  • [1] ALDERSON SW, 1962, AMER J ROENTGENOL RA, V87, P185
  • [2] [Anonymous], AAPM85
  • [3] [Anonymous], PIRS794REVB NRCC
  • [4] [Anonymous], 1989, ICRU Report No. 44
  • [5] Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates
    Berbeco, RI
    Nishioka, S
    Shirato, H
    Chen, GTY
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) : 3655 - 3667
  • [6] Measured lung dose correction factors for 50 MV photons
    Blomquist, M
    Karlsson, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (11) : 3225 - 3234
  • [7] Beam intensity modulation to reduce the field sizes for conformal irradiation of lung tumors: A dosimetric study
    Brugmans, MJP
    van der Horst, A
    Lebesque, JV
    Mijnheer, BJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04): : 893 - 904
  • [8] Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator
    Ding, GX
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) : 1025 - 1046
  • [9] Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
    Farajollahi A.
    Mesbahi A.
    [J]. Radiation Medicine, 2006, 24 (4): : 269 - 276
  • [10] Fujisaki Tatsuya, 2004, Radiat Med, V22, P233