Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study

被引:17
作者
Lambert, Lukas [1 ]
Danes, Jan [1 ]
Jahoda, Jiri [1 ]
Masek, Martin [1 ]
Lisy, Jiri [2 ,3 ]
Ourednicek, Petr [4 ]
机构
[1] Charles Univ Prague, Fac Med 1, Dept Radiol, Prague 12808 2, Czech Republic
[2] Charles Univ Prague, Fac Med 2, Dept Radiol, Prague 12808 2, Czech Republic
[3] Motol Univ Hosp, Prague, Czech Republic
[4] St Annes Univ Hosp, Dept Imaging Methods, Brno, Czech Republic
关键词
Colonography; polyp; low-dose; iterative reconstruction; computed tomography; colon; EXTRACOLONIC FINDINGS; RADIATION-EXPOSURE; COMPUTED-TOMOGRAPHY; CANCER; RISK; STANDARD;
D O I
10.1177/0284185114533683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed tomography (CT) colonography is a well established modality for the examination of symptomatic patients as well as in screening. Recent technical advances in improving image quality by iterative reconstruction contribute to the reduction of the radiation dose which is a major concern in CT imaging. Purpose: To evaluate image quality of ultralow-dose submilisievert CT colonography using hybrid iterative reconstruction technique. Material and Methods: Sixteen patients underwent contrast-enhanced CT colonography with standard protocol in supine position and ultralow-dose protocol in prone position. Ultralow-dose datasets were reconstructed with filtered back projection and an advanced hybrid iterative reconstruction technique. Two radiologists independently evaluated 96 colonic segments for image quality in the endoluminal view and axial thin sections. Colonic distension, smoothness of colonic wall and distortion of folds in the endoluminal view, sharpness of colonic wall delineation, perceived image noise, and presence of photon starvation artifact were rated on a five-point scale. Intraluminal noise expressed as standard deviation of Hounsfield density was measured in all segments. Results: The mean radiation dose was 0.42 mSv and 5.48 mSv in prone and supine scans, respectively. All distended segments were rated evaluable in standard dose and ultralow-dose series reconstructed with the iterative reconstruction technique, whereas in 61% segments image quality was rated poor or unacceptable in ultralow-dose series where filtered back projection was used with worst ratings in the rectum and the sigmoid colon. Conclusion: This pilot study shows that iterative reconstruction technique is a feasible method to decrease the radiation dose from CT colonography for both positions below 1mSv. Further investigations of larger scale need to be done to clarify, whether such a low radiation dose would influence the detection of polyps.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 27 条
[1]   Radiation Risk From CT: Implications for Cancer Screening [J].
Albert, Jeffrey M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) :W81-W87
[2]  
[Anonymous], 2011, IDOSE4 IT REC TECHN
[3]   Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms [J].
Badiani, Sarit ;
Tomas-Hernandez, Silvia ;
Karandikar, Sharad ;
Roy-Choudhury, Shuvro .
ACTA RADIOLOGICA, 2013, 54 (08) :851-862
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Mass screening with CT colonography: Should the radiation exposure be of concern? [J].
Brenner, DJ ;
Georgsson, MA .
GASTROENTEROLOGY, 2005, 129 (01) :328-337
[6]   A patient's viewpoint on a current controversy [J].
Casarella, WJ .
RADIOLOGY, 2002, 224 (03) :927-927
[7]   Dose reduction methods for CT colonography [J].
Chang, Kevin J. ;
Yee, Judy .
ABDOMINAL IMAGING, 2013, 38 (02) :224-232
[8]   Reducing Radiation Dose at CT Colonography: Decreasing Tube Voltage to 100 kVp [J].
Chang, Kevin J. ;
Caovan, Dominique B. ;
Grand, David J. ;
Huda, Walter ;
Mayo-Smith, William W. .
RADIOLOGY, 2013, 266 (03) :791-800
[9]   Feasibility of MDCT colonography in ultra-low-dose technique in the detection of colorectal lesions: Comparison with high-resolution video colonoscopy [J].
Cohnen, M ;
Vogt, C ;
Beck, A ;
Andersen, K ;
Heinen, W ;
vom Dahl, S ;
Aurich, V ;
Haeussinger, D ;
Moedder, U .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) :1355-1359
[10]   Radiation-Related Cancer Risks From CT Colonography Screening: A Risk-Benefit Analysis [J].
de Gonzalez, Amy Berrington ;
Kim, Kwang Pyo ;
Knudsen, Amy B. ;
Lansdorp-Vogelaar, Iris ;
Rutter, Carolyn M. ;
Smith-Bindman, Rebecca ;
Yee, Judy ;
Kuntz, Karen M. ;
van Ballegooijen, Marjolein ;
Zauber, Ann G. ;
Berg, Christine D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (04) :816-823