Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation

被引:0
|
作者
Mohammadi, Gh R. Fallah [1 ]
Hesamnezhad, L. [2 ]
Mahdavi, M. [2 ]
机构
[1] Mazandaran Univ Med Sci, Fac Allied Med, Dept Radiol, Sari, Iran
[2] Univ Mazandaran, Dept Phys, Babolsar, Iran
来源
关键词
Dose profile; CT scan; scatter radiation; CTDI phantom; MC simulation; CONE-BEAM CT; DOSIMETRY;
D O I
10.29242/ijrr.19.4.813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional radiation dosimetry methods in computed tomography (CT) are not able to measure the dose distribution along the patient's longitudinal axis. To calculate the dose index on a CT scan, the dose distribution from the center of the radiation field must be calculated. In this study, the most appropriate integral interval for calculating the CT dose index in the axial mode was determined using the Monte Carlo (MC) method based on X-ray photon energy and slice thickness. Materials and Methods: The computed tomography dose index (CTDI) phantom was simulated in the EGSnrc/BEAMnrcMC system and was irradiated with several X-ray energies and several slice thicknesses and dose profiles in phantom were investigated. The area under the dose profile and the scatter to primary radiation dose ratio (SPR) were calculated. Results: The range of scattered beams from the center of the radiation field reaches 450 mm in 140 kV and a 40 mm slice thickness. The SPR value for all levels of X-ray photon energy (between 80 and 140 kV) significantly decreases as slice thickness increases. CT scan imaging technical factors greater than 310 mm from the center of the slice thickness have no effect on the behavior of the scattered radiation. Conclusion: The primary beams are more affected by the energy of the photons, and the scatter beams are more strongly affected by the slice thickness. For 64-slice scanners, the polymethyl methacrylate (PMMA) phantom length should be between 700 mm and 900 mm to yield accurate CTDI estimations.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 50 条
  • [41] Monte Carlo simulation of a computed tomography x-ray tube
    Bazalova, Magdalena
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5945 - 5955
  • [42] The role of Monte Carlo simulation in understanding the performance of proton computed tomography
    Dedes, George
    Dickmann, Jannis
    Giacometti, Valentina
    Rit, Simon
    Krah, Nils
    Meyer, Sebastian
    Bashkirov, Vladimir
    Schulte, Reinhard
    Johnson, Robert P.
    Parodi, Katia
    Landry, Guillaume
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (01): : 23 - 38
  • [43] Coherent scatter imaging Monte Carlo simulation
    Hassan, Laila
    MacDonald, Carolyn A.
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [44] A Simple Scatter Reduction Method in Cone-Beam Computed Tomography for Dental and Maxillofacial Applications Based on Monte Carlo Simulation
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thajchayapong, Pairash
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [45] Monte Carlo investigation of scatter contribution to kilovoltage cone-beam computed tomography images
    Jarry, G
    Moseley, D
    Jaffray, D
    Verhaegen, F
    MEDICAL PHYSICS, 2005, 32 (06) : 2092 - 2092
  • [46] Evaluation of Organ Doses for Pediatric Computed Tomography Using a Newly Designed Radiophotoluminescence Glass Dosimeter and Comparison with a Monte Carlo Simulation-based Dose Calculator
    Chang, Weishan
    Koba, Yusuke
    HEALTH PHYSICS, 2021, 120 (03): : 288 - 295
  • [47] ESTIMATION OF COMPUTED TOMOGRAPHY DOSE INDEX IN CONE BEAM COMPUTED TOMOGRAPHY: MOSFET MEASUREMENTS AND MONTE CARLO SIMULATIONS
    Kim, Sangroh
    Yoshizumi, Terry
    Toncheva, Greta
    Yoo, Sua
    Yin, Fang-Fang
    Frush, Donald
    HEALTH PHYSICS, 2010, 98 (05): : 683 - 691
  • [48] Presentation of Organ Dose and Effective Dose Conversion Factors in Dual-Energy Computed Tomography: A Monte Carlo Simulation Study
    Pakravan, Delaram
    Journal of Biomedical Physics and Engineering, 2023, 13 (04): : 333 - 344
  • [49] Radiation dose assessement on dual and 16 slices MDCT using Monte Carlo simulation
    Mkimel, M.
    Mesradi, M. R.
    El Baydaoui, R.
    Toufique, Y.
    Halimi, A.
    Hilal, M.
    Saad, E.
    Hilali, A.
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 885 - 889
  • [50] Axial absorbed dose distributions during abdominal computed tomography acquisitions: Measurement and the Monte Carlo simulation study
    Matsubara, K.
    Nagata, H.
    Okubo, R.
    Ogawa, Y.
    Chusin, T.
    Hirosawa, A.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248