Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation

被引:0
|
作者
Mohammadi, Gh R. Fallah [1 ]
Hesamnezhad, L. [2 ]
Mahdavi, M. [2 ]
机构
[1] Mazandaran Univ Med Sci, Fac Allied Med, Dept Radiol, Sari, Iran
[2] Univ Mazandaran, Dept Phys, Babolsar, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2021年 / 19卷 / 04期
关键词
Dose profile; CT scan; scatter radiation; CTDI phantom; MC simulation; CONE-BEAM CT; DOSIMETRY;
D O I
10.29242/ijrr.19.4.813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional radiation dosimetry methods in computed tomography (CT) are not able to measure the dose distribution along the patient's longitudinal axis. To calculate the dose index on a CT scan, the dose distribution from the center of the radiation field must be calculated. In this study, the most appropriate integral interval for calculating the CT dose index in the axial mode was determined using the Monte Carlo (MC) method based on X-ray photon energy and slice thickness. Materials and Methods: The computed tomography dose index (CTDI) phantom was simulated in the EGSnrc/BEAMnrcMC system and was irradiated with several X-ray energies and several slice thicknesses and dose profiles in phantom were investigated. The area under the dose profile and the scatter to primary radiation dose ratio (SPR) were calculated. Results: The range of scattered beams from the center of the radiation field reaches 450 mm in 140 kV and a 40 mm slice thickness. The SPR value for all levels of X-ray photon energy (between 80 and 140 kV) significantly decreases as slice thickness increases. CT scan imaging technical factors greater than 310 mm from the center of the slice thickness have no effect on the behavior of the scattered radiation. Conclusion: The primary beams are more affected by the energy of the photons, and the scatter beams are more strongly affected by the slice thickness. For 64-slice scanners, the polymethyl methacrylate (PMMA) phantom length should be between 700 mm and 900 mm to yield accurate CTDI estimations.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 50 条
  • [41] Glandular dose in breast computed tomography with synchrotron radiation
    Mettivier, G.
    Fedon, C.
    Di Lillo, F.
    Longo, R.
    Sarno, A.
    Tromba, G.
    Russo, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02) : 569 - 587
  • [42] Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT
    Lazos, Dimitrios
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2010, 37 (10) : 5456 - 5470
  • [43] Variation in computed tomography radiation dose in community hospitals
    Calvert, Catherine
    Strauss, Keith J.
    Mooney, David P.
    JOURNAL OF PEDIATRIC SURGERY, 2012, 47 (06) : 1167 - 1169
  • [44] Monte Carlo simulation-based feasibility study of novel indirect flat panel detector system for removing scatter radiation
    Yoon, Yongsu
    Morishita, Junji
    Park, MinSeok
    Kim, Hyunji
    Kim, Kihyun
    Kim, Jungmin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 182 - 187
  • [45] DOSE POINT KERNEL SIMULATION FOR MONOENERGETIC ELECTRONS AND RADIONUCLIDES USING MONTE CARLO TECHNIQUES
    Wu, J.
    Liu, Y. L.
    Chang, S. J.
    Chao, M. M.
    Tsai, S. Y.
    Huang, D. E.
    RADIATION PROTECTION DOSIMETRY, 2012, 152 (1-3) : 119 - 124
  • [46] Investigation of imaging properties of novel contrast agents based on gold, silver and bismuth nanoparticles in spectral computed tomography using Monte Carlo simulation
    Sadeghian, Maryam
    Akhlaghi, Parisa
    Mesbahi, Asghar
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (01): : 21 - 29
  • [47] Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study
    Nevelsky, Alexander
    Borzov, Egor
    Daniel, Shahar
    Bar-Deroma, Raquel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 196 - 201
  • [48] A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes
    Papadimitroulas, Panagiotis
    Loudos, George
    Nikiforidis, George C.
    Kagadis, George C.
    MEDICAL PHYSICS, 2012, 39 (08) : 5238 - 5247
  • [49] Evaluation of Collapsed Cone Dose Calculation Algorithm for HDR Brachytherapy Using Monte Carlo
    Volken, W.
    Terribilini, D.
    Fix, M. K.
    Loessl, K.
    van Veelen, B.
    Manser, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] Benchmarking and validation of a Geant4-SHADOW Monte Carlo simulation for dose calculations in microbeam radiation therapy
    Cornelius, Iwan
    Guatelli, Susanna
    Fournier, Pauline
    Crosbie, Jeffrey C.
    del Rio, Manuel Sanchez
    Braeuer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 518 - 528