Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation

被引:0
|
作者
Mohammadi, Gh R. Fallah [1 ]
Hesamnezhad, L. [2 ]
Mahdavi, M. [2 ]
机构
[1] Mazandaran Univ Med Sci, Fac Allied Med, Dept Radiol, Sari, Iran
[2] Univ Mazandaran, Dept Phys, Babolsar, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2021年 / 19卷 / 04期
关键词
Dose profile; CT scan; scatter radiation; CTDI phantom; MC simulation; CONE-BEAM CT; DOSIMETRY;
D O I
10.29242/ijrr.19.4.813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional radiation dosimetry methods in computed tomography (CT) are not able to measure the dose distribution along the patient's longitudinal axis. To calculate the dose index on a CT scan, the dose distribution from the center of the radiation field must be calculated. In this study, the most appropriate integral interval for calculating the CT dose index in the axial mode was determined using the Monte Carlo (MC) method based on X-ray photon energy and slice thickness. Materials and Methods: The computed tomography dose index (CTDI) phantom was simulated in the EGSnrc/BEAMnrcMC system and was irradiated with several X-ray energies and several slice thicknesses and dose profiles in phantom were investigated. The area under the dose profile and the scatter to primary radiation dose ratio (SPR) were calculated. Results: The range of scattered beams from the center of the radiation field reaches 450 mm in 140 kV and a 40 mm slice thickness. The SPR value for all levels of X-ray photon energy (between 80 and 140 kV) significantly decreases as slice thickness increases. CT scan imaging technical factors greater than 310 mm from the center of the slice thickness have no effect on the behavior of the scattered radiation. Conclusion: The primary beams are more affected by the energy of the photons, and the scatter beams are more strongly affected by the slice thickness. For 64-slice scanners, the polymethyl methacrylate (PMMA) phantom length should be between 700 mm and 900 mm to yield accurate CTDI estimations.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 50 条
  • [31] Radiation dose evaluation of dental cone beam computed tomography using an anthropomorphic adult head phantom
    Wu, Jay
    Shih, Cheng-Ting
    Ho, Chang-hung
    Liu, Yan-Lin
    Chang, Yuan-Jen
    Chao, Max Min
    Hsu, Jui-Ting
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 287 - 291
  • [32] Lumbar discectomy and fusion: Organs? dose and effective dose estimation using Monte Carlo simulation
    Metaxas, Vasileios
    Efthymiou, Fotios
    Dimitroukas, Christos
    Delis, Harry
    Gatzounis, George
    Zampakis, Petros
    Tzortzidis, Fotios
    Papadakos, Dimitrios
    Constantoyannis, Constantine
    Panayiotakis, George
    APPLIED RADIATION AND ISOTOPES, 2023, 196
  • [33] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [34] Effective dose estimation in cone-beam computed tomography for dental use by Monte-Carlo simulation optimizing calculation numbers using a step-and-shoot method
    Ozaki, Yoshihiro
    Watanabe, Hiroshi
    Kurabayashi, Tohru
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (07)
  • [35] Monte Carlo modeling of radiation dose distributions in intravascular radiation therapy
    Stabin, MG
    Konijnenberg, M
    Knapp, FF
    Spencer, RH
    MEDICAL PHYSICS, 2000, 27 (05) : 1086 - 1092
  • [36] Modeling scattered radiation from dose compensator in CT by Forced Detection Monte Carlo simulation
    Bazargani, Negar
    Thompson, Richard A.
    Yagil, Yoad
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [37] Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations
    Benhalouche, S.
    Visvikis, D.
    Le Maitre, A.
    Pradier, O.
    Boussion, N.
    MEDICAL PHYSICS, 2013, 40 (02)
  • [38] Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models
    Sarno, Antonio
    Mettivier, Giovanni
    Tucciariello, Raffaele M.
    Bliznakova, Kristina
    Boone, John M.
    Sechopoulos, Ioannis
    Di Lillo, Francesca
    Russo, Paolo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 51 : 99 - 107
  • [39] Evaluation of computed tomography dose profiler probe for computed tomography dose index and geometric efficiency measurements
    Akhilesh, Philomina
    Pathan, M. S.
    Sharma, S. D.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06):
  • [40] Photon and Neutron Dose Estimation Using Monte Carlo Simulation in TrueBeam's Room
    Quoc, Soai Dang
    Fujibuchi, Toshioh
    Arakawa, Hiroyuki
    Hamada, Keisuke
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 473 - 479