Efficiency and energy requirements for the transformation of organic micropollutants by ozone, O3/H2O2 and UV/H2O2

被引:309
作者
Katsoyiannis, Ioannis A. [1 ]
Canonica, Silvio [1 ]
von Gunten, Urs [1 ,2 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, Dept Water Resources & Drinking Water, CH-8600 Dubendorf, Switzerland
[2] Ecole Polytech Fed Lausanne, Sch Architecture Civil & Environm Engn ENAC, CH-1015 Lausanne, Switzerland
关键词
Oxidation; Energy; Ozonation; O-3/H2O2; UV/H2O2; Scavenging rate; Micropollutants; BROMIDE-CONTAINING WATERS; RADICAL RATE CONSTANTS; ADVANCED OXIDATION; N-NITROSODIMETHYLAMINE; HYDROGEN-PEROXIDE; DRINKING-WATER; HYDROXYL RADICALS; BROMATE FORMATION; OZONATION; KINETICS;
D O I
10.1016/j.watres.2011.04.038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The energy consumptions of conventional ozonation and the AOPs O-3/H2O2 and UV/H2O2 for transformation of organic micropollutants, namely atrazine (ATR), sulfamethoxazole (SMX) and N-nitrosodimethylamine (NDMA) were compared. Three lake waters and a wastewater were assessed. With p-chlorobenzoic acid (pCBA) as a hydroxyl radical ((OH)-O-center dot) probe compound, we experimentally determined the rate constants of organic matter of the selected waters for their reaction with (OH)-O-center dot (k(OH,DOM)), which varied from 2.0 x 10(4) to 3.5 x 10(4) L mgC(-1) s(-1). Based on these data we calculated (OH)-O-center dot scavenging rates of the various water matrices, which were in the range 6.1-20 x 10(4) s(-1). The varying scavenging rates influenced the required oxidant dose for the same degree of micropollutant transformation. In ozonation, for 90% pCBA transformation in the water with the lowest scavenging rate (lake Zurich water) the required O-3 dose was roughly 2.3 mg/L, and in the water with the highest scavenging rate (Dubendorf wastewater) it was 13.2 mg/L, corresponding to an energy consumption of 0.035 and 0.2 kWh/m(3), respectively. The use of O-3/H2O2 increased the rate of micropollutant transformation and reduced bromate formation by 70%, but the H2O2 production increased the energy requirements by 20-25%. UV/H2O2 efficiently oxidized all examined micropollutants but energy requirements were substantially higher (For 90% pCBA conversion in lake Zurich water, 0.17-0.75 kWh/m(3) were required, depending on the optical path length). Energy requirements between ozonation and UV/H2O2 were similar only in the case of NDMA, a compound that reacts slowly with ozone and (OH)-O-center dot but is transformed efficiently by direct photolysis. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3811 / 3822
页数:12
相关论文
共 42 条
[31]   DECOMPOSITION OF OZONE IN WATER - RATE OF INITIATION BY HYDROXIDE IONS AND HYDROGEN-PEROXIDE [J].
STAEHELIN, J ;
HOIGNE, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1982, 16 (10) :676-681
[32]  
Stefan MI, 2002, HELV CHIM ACTA, V85, P1416, DOI 10.1002/1522-2675(200205)85:5<1416::AID-HLCA1416>3.0.CO
[33]  
2-I
[34]  
Stumm W., 2012, Aquatic Chemistry: Chemical Equilibria and Rates in Natural Waters
[35]  
Environmental Science and Technology: A Wiley-Interscience Series of Texts and Monographs
[36]   Advanced oxidation of bromide-containing waters: Bromate formation mechanisms [J].
Von Gunten, U ;
Oliveras, Y .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (01) :63-70
[37]   Ozonation of drinking water: Part I. Oxidation kinetics and product formation [J].
von Gunten, U .
WATER RESEARCH, 2003, 37 (07) :1443-1467
[38]   Ozonation of drinking water: Part II. Disinfection and by-product formation in presence of bromide, iodide or chlorine [J].
von Gunten, U .
WATER RESEARCH, 2003, 37 (07) :1469-1487
[39]   BROMATE FORMATION DURING OZONATION OF BROMIDE-CONTAINING WATERS - INTERACTION OF OZONE AND HYDROXYL RADICAL REACTIONS [J].
VONGUNTEN, U ;
HOLGNE, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (07) :1234-1242
[40]   Kinetics of the reaction between hydrogen peroxide and hypobromous acid: Implication on water treatment and natural systems [J].
VonGunten, U ;
Oliveras, Y .
WATER RESEARCH, 1997, 31 (04) :900-906