Radiotherapy planning for lung cancer: Slow CTs allow the drawing of tighter margins

被引:45
作者
Wurstbauer, K [1 ]
Deutschmann, H [1 ]
Kopp, P [1 ]
Sedlmayer, F [1 ]
机构
[1] Univ Klin Radiotherapie & Radioonkol, Salzburger Landesklin & Paracelsus Med Privatuniv, A-5020 Salzburg, Austria
关键词
lung cancer; conformal radiotherapy; radiotherapy planning; tumor motion; internal margin; planning target volume;
D O I
10.1016/j.radonc.2005.02.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Evaluation of the use of planning CTs with slow revolution time (4 s/slice; 'slow CTs') in the planning procedure of radiotherapy for lung cancer patients in comparison to commonly used 'fast' planning CTs; impact on margin assessment of planning target volume (PTV) design. Patients and methods: Eighteen lung cancer patients (six upper, lower lobe and central tumors, respectively) have been scanned each by three series of slow CTs and one fast CT (spiral CT). Patients have been freely breathing. The largest transversal tumor diameters in slow and fast CTs have been measured. Tumor edge positions have been determined for six spatial directions in all slices of the three slow CT series. Results: Slow CTs show larger dimensions of the visible tumor than fast CTs. The median difference of the diameter for all tumors is 2 mm (range 0-4 mm). Slow CTs deliver constant depictions of lung tumors within a range of 1.6 mm in all directions. This margin is considered to be sufficient to compensate for tumor movements by respiration and cardiovascular motions (internal margin). A margin of 7 mm added to the GTV of a single slow CT series to draw the PTV is proposed. Conclusions: Slow planning CTs show larger, but highly constant depictions of lung tumors in comparison to conventional fast CT scanning, yielding an integral delineation of almost all positions of the moving tumors. Thus the use of slow planning CTs enables the drawing of tighter margins in external beam treatment planning of lung cancer. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 1999, 62 ICRU
[2]   Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer [J].
Armstrong, J ;
Raben, A ;
Zelefsky, M ;
Burt, M ;
Leibel, S ;
Burman, C ;
Kutcher, G ;
Harrison, L ;
Hahn, C ;
Ginsberg, R ;
Rusch, V ;
Kris, M ;
Fuks, Z .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) :17-22
[3]   EFFECT OF CHEMOTHERAPY ON LOCALLY ADVANCED NON-SMALL-CELL LUNG-CARCINOMA - A RANDOMIZED STUDY OF 353 PATIENTS [J].
ARRIAGADA, R ;
LECHEVALIER, T ;
QUOIX, E ;
RUFFIE, P ;
DECREMOUX, H ;
DOUILLARD, JY ;
TARAYRE, M ;
PIGNON, JP ;
LAPLANCHE, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (06) :1183-1190
[4]   First results of a phase I/II dose escalation trial in non-small cell lung cancer using three-dimensional conformal radiotherapy [J].
Belderbos, JSA ;
De Jaeger, K ;
Heemsbergen, WD ;
Seppenwoolde, Y ;
Baas, P ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) :113-120
[5]   Accelerated hypofractionation for early-stage non-small-cell lung cancer [J].
Cheung, PCF ;
Yeung, LTF ;
Basrur, V ;
Ung, YC ;
Balogh, J ;
Danjoux, CE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (04) :1014-1023
[6]   Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Nijssen-Visser, MRJ ;
Graveland, WJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :348-354
[7]   Dosimetric consequences of tumor mobility in radiotherapy of stage I non-small cell lung cancer - an analysis of data generated using 'slow' CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Schuchhard-Schipper, RH ;
Nijssen-Visser, MRJ ;
Voet, PWJ ;
Oei, SS ;
Senan, S .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (01) :93-99
[8]   What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? [J].
Ekberg, L ;
Holmberg, O ;
Wittgren, L ;
Bjelkengren, G ;
Landberg, T .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) :71-77
[9]   Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning [J].
Giraud, P ;
Antoine, M ;
Larrouy, A ;
Milleron, B ;
Callard, P ;
De Rycke, Y ;
Carette, MF ;
Rosenwald, JC ;
Cosset, JM ;
Housset, M ;
Touboul, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04) :1015-1024
[10]   Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) [J].
Graham, MV ;
Purdy, JA ;
Emami, B ;
Harms, W ;
Bosch, W ;
Lockett, MA ;
Perez, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :323-329