Minimally invasive vertebroplasty managed by a two C-arm fluoroscopic technique

被引:10
作者
Li, Yen-Yao [1 ]
Hsu, Robert Wen-Wei [1 ]
Cheng, Chin-Chang [1 ]
Huang, Tsung-Jen [1 ]
机构
[1] Chang Gung Univ, Chang Gung Mem Hosp, Coll Med, Dept Orthopaed Surg, Putz City, Chiayi County, Taiwan
关键词
minimally invasive vertebroplasty; two C-arm fluoroscopic technique; cement leakage;
D O I
10.1080/13645700701627654
中图分类号
R61 [外科手术学];
学科分类号
摘要
One C-arm fluoroscope is widely considered to be sufficient for effectively monitoring minimally invasive vertebroplasty. However, rotating the C-arm fluoroscope for different radiographic views of the spine can be time-consuming, causing delay in detecting cement leakage. We retrospectively reviewed the results of minimally invasive vertebroplasty utilizing two C-arm fluoroscopes in the treatment of osteoporotic vertebral fractures. Forty-two patients ( 50 vertebrae) were treated with minimally invasive vertebroplasty under the guidance of two C-arm fluoroscopes. The mean operation time, patient satisfaction rate and the incidences of cement leakage or infection were used to evaluate the feasibility and efficacy of the two C-arm fluoroscopic technique in performing minimally invasive vertebroplasty. The mean follow-up duration was 17.4 months (range 6 similar to 36). The mean operation time was 37 +/- 14 minutes. Thirty patients (71%) were very satisfied or satisfied with the procedure. Cement leakages were identified in nine patients ( nine vertebrae, 18%). Only one vertebra had a posterior leakage into spinal canal, which did not cause neurologic deficits. No wound infection was observed. This study indicates that the two C-arm fluoroscopic technique provides simultaneous antero-posterior and lateral radiographic views, and therefore may reduce the operation time. No symptomatic cement leakage or wound infection was noted in this investigation. Moreover, no additional staff is needed to rotate the C-arm for fluoroscopy. The proposed technique has been shown to be effective and useful for performing minimally invasive vertebroplasty.
引用
收藏
页码:350 / 354
页数:5
相关论文
共 17 条
  • [11] Percutaneous placement of iliosacral screws for unstable pelvic ring injuries: Comparison between one and two C-arm fluoroscopic techniques
    Peng, KT
    Huang, KC
    Chen, MC
    Li, YY
    Hsu, RWW
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (03): : 602 - 608
  • [12] Prymka M, 2003, UNFALLCHIRURG, V106, P860, DOI 10.1007/s00113-003-0644-3
  • [13] Spondylitis following vertebroplasty: a case report
    Schmid, KE
    Boszczyk, BM
    Bierschneider, M
    Zarfl, A
    Robert, B
    Jaksche, H
    [J]. EUROPEAN SPINE JOURNAL, 2005, 14 (09) : 895 - 899
  • [14] Cement leakage during vertebroplasty: an underestimated problem?
    Schmidt, R
    Cakir, B
    Mattes, T
    Wegener, M
    Puhl, W
    Richter, M
    [J]. EUROPEAN SPINE JOURNAL, 2005, 14 (05) : 466 - 473
  • [15] Walker David H, 2004, Neurosurg Focus, V17, pE6
  • [16] CT-based analysis of cement distribution in unipedicular vertebroplasty
    Walz M.
    Esmer E.
    Kolbow B.
    [J]. Der Unfallchirurg, 2006, 109 (11): : 932 - 939
  • [17] Serious pyogenic spondylitis following vertebroplasty - A case report
    Yu, SW
    Chen, WJ
    Lin, WC
    Chen, YJ
    Tu, YK
    [J]. SPINE, 2004, 29 (10) : E209 - E211