Gadobutrol versus gadofosveset-trisodium in MR venography of the lower extremities

被引:4
作者
Arnoldussen, Carsten W. K. P. [1 ,2 ]
Lam, Yeelai [3 ]
Ito, Nobutake [4 ,5 ]
Winkens, Bjorn [6 ]
Kooi, M. Eline [1 ,7 ]
Wittens, Cees H. A. [8 ]
Wildberger, Joachim E. [1 ,7 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiol, POB 5800,P Debyelaan 25, NL-6202 AZ Maastricht, Netherlands
[2] VieCuri Med Ctr, Dept Radiol, Venlo, Netherlands
[3] Maastricht Univ Med Ctr, Dept Vasc Surg, Maastricht, Netherlands
[4] Natl Hosp Org Tokyo Med Ctr, Dept Diagnost Radiol, Tokyo, Japan
[5] Keio Univ Hosp, Dept Diagnost Radiol, Tokyo, Japan
[6] Maastricht Univ, Dept Methodol & Stat, Maastricht, Netherlands
[7] Maastricht Univ Med Ctr, CARIM, Sch Cardiovasc Dis, Maastricht, Netherlands
[8] Univ Hosp RWTH Aachen, Dept Vasc Surg, Aachen, Germany
关键词
MRI; MR venography; Venous; Chronic venous disease; Chronic venous obstruction; MAGNETIC-RESONANCE ANGIOGRAPHY; DOSE GADOPENTETATE DIMEGLUMINE; GADOBENATE DIMEGLUMINE; PERIPHERAL ARTERIES; INITIAL-EXPERIENCE; RENAL-ARTERIES; 3.0; T; MULTICENTER; THROMBOSIS; VEINS;
D O I
10.1007/s00330-017-4902-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR venography (MRV) protocols have used bloodpool contrast agents and long scan sequences to identify patients suitable for treatment and preoperatively. However, variable availability of bloodpool contrast agents, high costs and a need to shorten acquisition times for routine MR protocols hamper everyday practice. 20 patients (11 men; mean age 54 +/- 11.8 years; body mass index 23.6 +/- 2.5) were enrolled in this prospective study. An intra-individual comparison of image quality, interpretation and findings for two different contrast agents (regular gadolinium contrast agent gadobutrol vs. bloodpool contrast agent gadofosveset-trisodium) and two different scan protocols (long acquisition time protocol using a high-resolution fast field echo (FFE) sequence vs. short acquisition time protocol using an ultra-fast gradient echo (GE) sequence) were performed. Image quality (average of 4.94 vs. 4.92 on a five-point scale), interpretation and contrast-to-noise ratio (44 vs. 45) were equal for both contrast agents. Image findings showed no statistical significant differences between the MR protocols or contrast agents (overall p = 0.328). For high-resolution MRV, it is possible to replace gadofosveset-trisodium with gadobutrol. Furthermore, an ultra-fast GE sequence for MRV might considerably shorten acquisition time, without loss of image quality or diagnostic yield. aEuro cent High-quality MRV can be performed with a regular gadolinium-based contrast agent. aEuro cent Ultra-fast GRE vs. HR-FFE MRV: equally suitable for evaluation of venous obstruction. aEuro cent Regular gadolinium-based contrast agent can supersede a bloodpool contrast agent for MRV. aEuro cent Equal confidence for gadobutrol vs gadofosveset-trisodium in MRV. aEuro cent MRV accessible for routine daily practice.
引用
收藏
页码:4986 / 4994
页数:9
相关论文
共 25 条
[1]  
Arnoldussen CWKP, 2012, PHLEBOLOGY, V27, P163, DOI [10.1258/phleb.2012.012s26, 10.1258/phleb.2012.012S26]
[2]   Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: Interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T [J].
Attenberger, Ulrike I. ;
Michaely, Henrik J. ;
Wintersperger, Bernd J. ;
Sourbron, Steven P. ;
Lodemann, Klaus-Peter ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1260-1268
[3]  
Bayer Healthcare, 2015, GAD GAD US PRESCR IN
[4]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[5]   Visualization of Deep Veins and Detection of Deep Vein Thrombosis (DVT) With Balanced Turbo Field Echo (b-TFE) and Contrast-Enhanced T1 Fast Field Echo (CE-FFE) Using a Blood Pool Agent (BPA) [J].
Enden, Tone ;
Storas, Tryggve H. ;
Negard, Anne ;
Haig, Ylva ;
Sandvik, Leiv ;
Gjesdal, Kjell-Inge ;
Sandset, Per Morten ;
Klow, Nils-Einar .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (02) :416-424
[6]   A comparison of two methods for measuring the signal to noise ratio on MR images [J].
Firbank, MJ ;
Coulthard, A ;
Harrison, RM ;
Williams, ED .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :N261-N264
[7]   Quality assurance for MRI: practical experience [J].
Firbank, MJ ;
Harrison, RM ;
Williams, ED ;
Coulthard, A .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868) :376-383
[8]  
Gaitini D, 2007, INT J BIOMED IMAGING, V2007, P546
[9]   Multicenter, Double-Blind, Randomized, Intraindividual Crossover Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine for MR Angiography of Peripheral Arteries [J].
Gerretsen, Suzanne C. ;
le Maire, Thierry F. ;
Miller, Stephan ;
Thurnher, Siegfried A. ;
Herborn, Christoph U. ;
Michaely, Henrik J. ;
Kramer, Harald ;
Vanzulli, Angelo ;
Vymazal, Josef ;
Wasser, Martin N. ;
Ballarati, Claudio E. M. ;
Kirchin, Miles A. ;
Pirovano, Gianpaolo ;
Leiner, Tim .
RADIOLOGY, 2010, 255 (03) :988-1000
[10]   Direct contrast-enhanced MR venography in the diagnosis of May-Thurner Syndrome [J].
Gurel, Kamil ;
Gurel, Safiye ;
Karavas, Erdal ;
Buharalioglu, Yavuz ;
Daglar, Bahadir .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) :533-536