Comparative evaluation of software for retention time alignment of gas chromatography/time-of-flight mass spectrometry-based metabonomic data

被引:50
作者
Koh, Yueting [1 ]
Pasikanti, Kishore Kumar [1 ]
Yap, Chun Wei [1 ]
Chan, Eric Chun Yong [1 ]
机构
[1] Natl Univ Singapore, Fac Sci, Dept Pharm, Singapore 117543, Singapore
基金
英国医学研究理事会;
关键词
Retention time alignment; Peak alignment; Gas chromatography/mass spectrometry; Data processing; Metabonomics; Metabolomics; IDENTIFYING DIFFERENCES; PEAK ALIGNMENT; BLADDER-CANCER; PROFILE DATA; HUMAN URINE; METABOLOMICS; GC/MS; SAMPLES; TOOL; IDENTIFICATION;
D O I
10.1016/j.chroma.2010.10.101
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In chromatography-based metabonomic research, retention time (RT) alignment of chromatographic peaks poses a challenge for the accurate profiling of biomarkers. Although a number of RT alignment software has been reported, the performance of these software packages have not been comprehensively evaluated. This study aimed to evaluate the RT alignment accuracy of publicly available and commercial RT alignment software. Two gas chromatography/mass spectrometry (GC/MS) datasets acquired from a mixture of standard metabolites and human bladder cancer urine samples, were used to assess three publicly available software packages, MetAlign. MZmine and TagFinder, and two commercial applications comprising the Calibration feature and Statistical Compare of ChromaTOF software. The overall RT alignment accuracies in aligning standard compounds mixture were 93, 92, 74, 73 and 42% for Calibration feature, MZmine, MetAlign, Statistical Compare and TagFinder, respectively. Additionally, unique trends were observed for the individual software with regards to the different experimental conditions related to extent and direction of RT shifts. Conflicting performance was observed for human urine samples suggesting that RT misalignments still occurred despite the use of RT alignment software. While RT alignment remains an inevitable step in data preprocessing, metabonomic researchers are recommended to perform manual check on the RT alignment of important biomarkers as part of their validation process. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:8308 / 8316
页数:9
相关论文
共 40 条
[1]   The correspondence problem for metabonomics datasets [J].
Aberg, K. Magnus ;
Alm, Erik ;
Torgrip, Ralf J. O. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) :151-162
[2]   MET-IDEA: Data extraction tool for mass spectrometry-based metabolomics [J].
Broeckling, Corey D. ;
Reddy, Indira R. ;
Duran, Anthony L. ;
Zhao, Xuechun ;
Sumner, Lloyd W. .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4334-4341
[3]   Metabolomics spectral formatting, alignment and conversion tools (MSFACTs) [J].
Duran, AL ;
Yang, J ;
Wang, LJ ;
Sumner, LW .
BIOINFORMATICS, 2003, 19 (17) :2283-2293
[4]   Retention-time locked methods in gas chromatography [J].
Etxebarria, Nestor ;
Zuloaga, Olatz ;
Olivares, Maitane ;
Bartolome, Luis J. ;
Navarro, Patricia .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (10) :1624-1629
[5]   Extending the breadth of metabolite profiling by gas chromatography coupled to mass spectrometry [J].
Fiehn, Oliver .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (03) :261-269
[6]   Carbohydrate profiling of bacteria by gas chromatography-mass spectrometry and their trace detection in complex matrices by gas chromatography-tandem mass spectrometry [J].
Fox, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :287-300
[7]   MetaboliteDetector: Comprehensive Analysis Tool for Targeted and Nontargeted GC/MS Based Metabolome Analysis [J].
Hiller, Karsten ;
Hangebrauk, Jasper ;
Jager, Christian ;
Spura, Jana ;
Schreiber, Kerstin ;
Schomburg, Dietmar .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3429-3439
[8]   ChromA: signal-based retention time alignment for chromatography-mass spectrometry data [J].
Hoffmann, Nils ;
Stoye, Jens .
BIOINFORMATICS, 2009, 25 (16) :2080-2081
[9]   Utility of separation science in metabolomic studies [J].
Issaq, Haleem J. ;
Abbott, Eric ;
Veenstra, Timothy D. .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (11) :1936-1947
[10]   Detection of bladder cancer in human urine by metabolomic profiling using high performance liquid chromatography/mass spectrometry [J].
Issaq, Haleem J. ;
Nativ, Ofer ;
Waybright, Timothy ;
Luke, Brian ;
Veenstra, Timothy D. ;
Issaq, Elias J. ;
Kravstov, Alexander ;
Mullerad, Michael .
JOURNAL OF UROLOGY, 2008, 179 (06) :2422-2426