Chemical sensors based on multiresponsive block copolymer hydrogels

被引:61
作者
Guenther, M.
Kuckling, D.
Corten, C.
Gerlach, G.
Sorber, J.
Suchaneck, G.
Arndt, K.-F.
机构
[1] Tech Univ Dresden, Inst Solid State Elect, D-01069 Dresden, Germany
[2] Tech Univ Dresden, Dept Chem & Food Chem, D-01069 Dresden, Germany
关键词
chemical sensor; hydrogel; swelling behaviour; temperature-sensitive; pH-sensitive; solution composition;
D O I
10.1016/j.snb.2006.10.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to realize a chemical sensor with a high signal reproducibility, a thermo-shrinking photo cross-linkable co- and terpolyrner of N-isopropylacrylamide (NIPAAm), 2-(dimethyl maleimido)-N-ethylacrylamide (DMIAAm) as the chromophore and poly(2-vinylpyridine) (P2VP) (or N,N-dimethylacrylamide (DMAAm), respectively) has been used as chemo-mechanical transducer. Commercially available pressure sensor chips with a flexible thin silicon bending plate have been employed as mechano-electrical transducer for the transformation of bending plate deflection into an corresponding electrical output signal. A thin film of the photo cross-linkable hydrogel has been deposited onto the backside of the silicon bending plate and irradiated with UV light. The aqueous solution to be measured has been pumped through inlet tubes into the silicon chip cavity and induces swelling or shrinking processes of the hydrogel. Changes in the polymer composition have allowed to vary the gel volume phase transition temperature (T-c) from 25 degrees C for P2VP-block-P(NIPAAm-co-DMIAAm) to 43 degrees C for NIPAAm-DMIAAm-DMAAm terpolymer. The combination of the temperature-sensitive PNIPAAm with a pH-sensitive P2VP component allowed us to realize a pH sensor with a long-term stable signal in the pH range between 2 and 5. In addition, the sensitivity of the sensors with regard to concentration changes of different inorganic solutes has been studied. The influence of an initial gel-conditioning procedure on the signal value as well as the sensitivity of the proposed chemical sensors was investigated. Measurement conditions necessary for high signal reproducibility and a long-term stability were determined. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 40 条
[21]   Temperature and pH-dependent swelling behavior of poly(N-isopropylacrylamide) copolymer hydrogels and their use in flow control [J].
Kuckling, D ;
Richter, A ;
Arndt, KF .
MACROMOLECULAR MATERIALS AND ENGINEERING, 2003, 288 (02) :144-151
[22]   Photo-cross-linkable PNIPAAm copolymers. 1. Synthesis and characterization of constrained temperature-responsive hydrogel layers [J].
Kuckling, D ;
Harmon, ME ;
Frank, CW .
MACROMOLECULES, 2002, 35 (16) :6377-6383
[23]   Temperature sensitive polymers based on 2-(dimethyl maleinimido)-N-ethyl-acrylamide:: Copolymers with N-isopropylacrylamide [J].
Kuckling, D ;
Adler, HJP ;
Ling, L ;
Habicher, WD ;
Arndt, KF .
POLYMER BULLETIN, 2000, 44 (03) :269-276
[24]   Radiation induced synthesis and swelling characterization of thermo-responsive N-isopropylacrylamide-co-ionic hydrogels [J].
Kumar, V ;
Chaudhari, CV ;
Bhardwaj, YK ;
Goel, NK ;
Sabharwal, S .
EUROPEAN POLYMER JOURNAL, 2006, 42 (02) :235-246
[25]   Demonstration of etched cladding fiber Bragg grating-based sensors with hydrogel coating [J].
Liu, XM ;
Zhang, XM ;
Cong, J ;
Xu, J ;
Chen, KS .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (1-2) :468-472
[26]   Water structure in aqueous solutions of alkali halide salts: FTIR spectroscopy of the OD stretching band [J].
Nickolov, ZS ;
Miller, JD .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 287 (02) :572-580
[27]   Chemical modulation of thermosensitive poly (N-isopropylacrylamide) microsphere swelling:: a new strategy for chemical sensing [J].
Oktar, O ;
Caglar, P ;
Seitz, WR .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02) :179-185
[28]   Reentrant conformation transition in poly(N,N-dimethylacrylamide) hydrogels in water-organic solvent mixtures [J].
Orakdogen, N ;
Okay, O .
POLYMER, 2006, 47 (02) :561-568
[29]   Influence of the synthesis conditions and ionic additives on the swelling behaviour of thermo-responsive polyalkylacrylamide hydrogels [J].
Panayiotou, M ;
Freitag, R .
POLYMER, 2005, 46 (18) :6777-6785
[30]   Characterization of a microgravimetric sensor based on pH sensitive hydrogels [J].
Richter, A ;
Bund, A ;
Keller, M ;
Arndt, KF .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3) :579-585