Characterization of SiO2 nanoparticles by single particle-inductively coupled plasma-tandem mass spectrometry (SP-ICP-MS/MS)

被引:48
作者
Bolea-Fernandez, Eduardo [1 ]
Leite, Diego [2 ]
Rua-Ibarz, Ana [1 ]
Balcaen, Lieve [1 ]
Aramendia, Maite [2 ,3 ]
Resano, Martin [2 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Ghent, Dept Analyt Chem, Campus Sterre,Krijgslaan 281-S12, B-9000 Ghent, Belgium
[2] Univ Zaragoza, Aragon Inst Engn Res I3A, Dept Analyt Chem, Pedro Cerbuna 12, E-50009 Zaragoza, Spain
[3] Ctr Univ Defensa, Carretera Huesca S-N, Zaragoza 50090, Spain
关键词
FIELD-FLOW FRACTIONATION; ATOMIC-ABSORPTION-SPECTROMETRY; SILICA NANOPARTICLES; REACTION CELL; MS; SIZE; QUANTIFICATION; PERFORMANCE; NUMBER; TOOL;
D O I
10.1039/c7ja00138j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The increase in the use of SiO2 nanoparticles (NPs) is raising concern about their environmental and health effects, thus necessitating the development of novel methods for their straightforward detection and characterization. Single particle ICP-mass spectrometry (SP-ICP-MS) is able to provide information on the size of NPs, their particle number density and mass concentration. However, the determination of Si via ICP-MS is strongly hampered by the occurrence of spectral overlap from polyatomic species (e.g., CO+ and N-2(+)). The use of tandem ICP-MS (ICP-MS/MS) enables interference-free conditions to be obtained, even in the most demanding applications. Upon testing several gases, the use of CH3F (monitoring of SiF+, mass-shift approach) and of H-2 (monitoring of Si+, on-mass approach) were demonstrated to be the most suitable to overcome the spectral interference affecting ultra-trace Si determination (LoD < 15 ng L-1). By using these approaches, SiO2 NPs (ranging between 80 and 400 nm) can be detected and characterized. For SiO2 NPs > 100 nm, it was possible to provide accurate results in a straightforward way, as the signals they give rise to are well resolved from those of the background. In the case of 80 and 100 nm NPs, the use of a simple deconvolution approach following a Gaussian model was needed to characterize SiO2 NPs apparently showing incomplete distributions as a result of the presence of the background signal. Overall, the methods developed using SP-ICP-MS/MS are sensitive and selective enough for the interference-free determination of Si at ultra-trace levels, also in the form of SiO2 NPs.
引用
收藏
页码:2140 / 2152
页数:13
相关论文
共 51 条
  • [1] Evaluation of number concentration quantification by single-particle inductively coupled plasma mass spectrometry: microsecond vs. millisecond dwell times
    Abad-Alvaro, Isabel
    Pena-Vazquez, Elena
    Bolea, Eduardo
    Bermejo-Barrera, Pilar
    Castillo, Juan R.
    Laborda, Francisco
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (19) : 5089 - 5097
  • [2] Determination of P, S and Si in biodiesel, diesel and lubricating oil using ICP-MS/MS
    Amais, Renata S.
    Amaral, Clarice D. B.
    Fialho, Lucimar L.
    Schiavo, Daniela
    Nobrega, Joaquim A.
    [J]. ANALYTICAL METHODS, 2014, 6 (13) : 4516 - 4520
  • [3] Aureli F, 2015, J ANAL ATOM SPECTROM, V30, P1266, DOI [10.1039/C4JA00478G, 10.1039/c4ja00478g]
  • [4] Accurate determination of S in organic matrices using isotope dilution ICP-MS/MS
    Balcaen, Lieve
    Woods, Glenn
    Resano, Martin
    Vanhaecke, Frank
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (01) : 33 - 39
  • [5] Inductively coupled plasma - Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra) trace elements - A tutorial review
    Balcaen, Lieve
    Bolea-Fernandez, Eduardo
    Resano, Martin
    Vanhaecke, Frank
    [J]. ANALYTICA CHIMICA ACTA, 2015, 894 : 7 - 19
  • [6] Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS
    Balcaen, Lieve
    Bolea-Fernandez, Eduardo
    Resano, Martin
    Vanhaecke, Frank
    [J]. ANALYTICA CHIMICA ACTA, 2014, 809 : 1 - 8
  • [7] Determination of Size- and Number-Based Concentration of Silica Nanoparticles in a Complex Biological Matrix by Online Techniques
    Bartczak, Dorota
    Vincent, Phil
    Goenaga-Infante, Heidi
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (11) : 5482 - 5485
  • [8] Overcoming spectral overlap via inductively coupled plasma-tandem mass spectrometry (ICPMS/MS). A tutorial review
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (09) : 1660 - 1679
  • [9] Tandem ICP-mass spectrometry for Sr isotopic analysis without prior Rb/Sr separation
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (01) : 303 - 310
  • [10] Potential of Methyl Fluoride as a Universal Reaction Gas to Overcome Spectral Interference in the Determination of Ultratrace Concentrations of Metals in Biofluids Using Inductively Coupled Plasma-Tandem Mass Spectrometry
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7969 - 7977