A novel gold nanostars-based fluorescent aptasensor for aflatoxin B1 detection

被引:43
|
作者
Wei, Min [1 ]
Zhao, Fei [1 ]
Xie, Yanli [1 ]
机构
[1] Henan Univ Technol, Henan Key Lab Cereal & Oil Food Safety Inspect &, Coll Food Sci & Technol, Zhengzhou 450001, Peoples R China
关键词
AuNSs; Fluorescence quenching; Aptamer; Aflatoxin B1; ELECTROCHEMICAL APTASENSOR; ULTRASENSITIVE DETECTION; SIGNAL AMPLIFICATION; APTAMER; B-1; NANOPARTICLES; IMMUNOASSAY; OCHRATOXIN; PLATFORM; PEANUT;
D O I
10.1016/j.talanta.2019.120599
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a simple and sensitive fluorescent aptasensor for aflatoxin B1 (AFB(1)) detection was proposed using gold nanostars (AuNSs) as a novel fluorescence quenching material. Carboxyfluorescein-labeled complementary DNA with hairpin structure (FAM-labeled HP) was designed to hybridize with AFB(1) aptamer to form double-stranded DNA, resulting in the opening of hairpin structure. When double-stranded DNA was modified on AuNSs surface, FAM was far from AuNSs and produced a strong fluorescence intensity. The introduction of AFB(1) in the system led to the specific interaction of AFB(1) and aptamer, and changed the conformation of aptamer, inducing the release of aptamer from double-stranded DNA and the restoration of hairpin structure. Fluorescence quenching occurred when FAM was close to AuNSs, and the fluorescence intensity decreased. In the presence of 5 ng/mL AFB(1), Delta F/F-0 of the AuNSs/FAM-labeled HP/Apt was similar to 44.2%, higher than that of the AuNPs/FAM-labeled HP/Apt, indicating the better quenching effect of AuNSs. The change of fluorescence intensity linearly increased by adding AFB(1) in the concentration range of 0.1 ng/mL-10 ng/mL, with the LOD of 21.3 pg/mL. The proposed aptasensor exhibited good selectivity in the presence of other toxins at 10-fold concentration of AFB(1), and showed satisfactory recovery in the range of 92%-112% toward AFB(1) detection in spiked corn flour sample.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Optical approaches for the simple and sensitive detection of aflatoxin B1 via a liquid crystal aptasensor
    Yang, Xin
    Li, Xinyue
    Jin, Junyang
    Ma, Junchi
    Liu, Jinghua
    An, Zongfu
    LIQUID CRYSTALS, 2023, 50 (04) : 652 - 662
  • [42] A comb-shaped microfluidic aptasensor for rapid and sensitive on-site simultaneous detection of aflatoxin B1 and deoxynivalenol
    Wu, Jinlei
    Yuan, Haojun
    Yang, Yunhua
    Yang, Ping
    Yan, Xinxin
    Mu, Ying
    Jin, Qinghui
    Yang, Panhui
    Gao, Wanlei
    FOOD CHEMISTRY, 2025, 473
  • [43] An electrochemical aptasensor based on polythiophene-3-carboxylic acid assisted methylene blue for aflatoxin B1 detection
    Zejli, Hanane
    Goud, K. Yugender
    Marty, Jean Louis
    SENSING AND BIO-SENSING RESEARCH, 2019, 25
  • [44] Gold nanoparticle-catalyzed uranine reduction for signal amplification in fluorescent assays for melamine and aflatoxin B1
    Wang, Xu
    Pauli, Jutta
    Niessner, Reinhard
    Resch-Genger, Ute
    Knopp, Dietmar
    ANALYST, 2015, 140 (21) : 7305 - 7312
  • [45] A Novel Graphene Oxide-Based Aptasensor for Amplified Fluorescent Detection of Aflatoxin M1 in Milk Powder
    Guo, Xiaodong
    Wen, Fang
    Qiao, Qinqin
    Zheng, Nan
    Saive, Matthew
    Fauconnier, Marie-Laure
    Wang, Jiaqi
    SENSORS, 2019, 19 (18)
  • [46] A novel electrochemical aptasensor based on AuNPs-loaded graphene oxide-polyaniline for sensitive detection of aflatoxin B1
    Li, Ningbo
    Wang, Yuxin
    Zhou, Xue
    Hu, Chuqian
    He, Xu
    Qiao, Jie
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (08) : 2973 - 2984
  • [47] An amplifiable ratiometric fluorescent aptasensor for aflatoxin B1 detection based on dendrimer-like DNA nanostructures coupled with catalytic hairpin self-assembly
    Zhao, Luyang
    Suo, Zhiguang
    Liu, Yong
    Wei, Min
    Jin, Huali
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 380
  • [48] Novel colorimetric immunoassay for the detection of aflatoxin B1
    Garden, SR
    Strachan, NJC
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 187 - 191
  • [49] Fabricating photoelectrochemical aptasensor for sensitive detection of aflatoxin B1 with visible-light-driven BiOBr/nitrogen-doped graphene nanoribbons
    Chen, Wei
    Zhu, Mingyue
    Liu, Qian
    Guo, Yingshu
    Wang, Huaisheng
    Wang, Kun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 840 : 67 - 73
  • [50] A Fluorescence Resonance Energy Transfer Aptasensor for Aflatoxin B1 Based on Ligand-Induced ssDNA Displacement
    Serebrennikova, Kseniya V.
    Samokhvalov, Alexey V.
    Zherdev, Anatoly V.
    Dzantiev, Boris B.
    MOLECULES, 2023, 28 (23):