Intraocular Pressure Values Obtained by Ocular Response Analyzer, Dynamic Contour Tonometry, and Goldmann Tonometry in Keratokonic Corneas

被引:16
|
作者
Bayer, Atilla [1 ]
Sahin, Afsun
Hurmeric, Volkan
Ozge, Gokhan
机构
[1] Gulhane Mil Med Acad, Dept Ophthalmol, Ankara, Turkey
关键词
dynamic contour tonometry; goldmann applanation tonometer; intraocular pressure; keratoconus; ocular response analyzer; APPLANATION TONOMETRY; BIOMECHANICAL PROPERTIES; THICKNESS; EYES; KERATOCONUS; PARAMETERS;
D O I
10.1097/IJG.0b013e3181ca7aeb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the agreement between dynamic contour tonometer (DCT), Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA) in keratoconic corneas and to find out the effect of corneal biomechanics on intraocular pressure (IOP) measurements obtained by these devices. Subjects and Methods: IOP was measured with the ORA, DCT, and GAT in random order in 120 eyes of 61 keratoconus patients. Central corneal thickness (CCT) and keratometry were measured after all IOP determinations had been made. The mean IOP measurement by the ORA and DCT was compared with the measurement by the GAT, using Student t test. Bland-Altman analysis was performed to assess the clinical agreement between these methods. The effect of corneal hysteresis (CH), corneal resistance factor (CRF), and CCT on measured IOP was explored by multiple backward stepwise linear regression analysis. Results: The mean +/- SD patient age was 30.6 +/- 11.2 years. The mean +/- SD IOP measurement obtained with GAT, ORA Goldmann-correlated IOP (IOPg), ORA corneal-compensated IOP (IOPcc), and DCT was 10.96 +/- 2.8, 10.23 +/- 3.5, 14.65 +/- 2.8, and 15.42 +/- 2.7 mm Hg, respectively. The mean +/- SD CCT was 464.08 +/- 58.4 microns. The mean difference between IOPcc and GAT (P<0.0001), IOPcc and DCT (P<0.001), GAT and DCT (P<0.0001), IOPg and GAT (P<0.002), and IOPg and DCT (P<0.0001), was highly statistically significant. In multivariable regression analysis, DCT IOP and GAT IOP measurements were significantly associated with CH and CRF (P<0.0001 for both). Conclusions: DCT seemed to be affected by CH and CRF, and the IOP values tended to be higher when compared with GAT. ORA-measured IOPcc was found to be independent of CCT and suitable in comparison to the DCT in keratoconic eyes.
引用
收藏
页码:540 / 545
页数:6
相关论文
共 50 条
  • [21] Intraocular pressure elevation after vitrectomy-Goldmann applanation tonometry measures lower intraocular pressure than dynamic contour tonometry
    Baeurle, Sebastian
    Viestenz, Anja
    Seitz, Berthold
    Viestenz, Arne
    OPHTHALMOLOGIE, 2022, 119 : S71 - S76
  • [22] Comparison of Goldmann applanation tonometry and dynamic contour tonometry for measuring intraocular pressure in normal tension glaucomatous eyes
    Wang, Jing Grace
    Latina, Mark A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [23] Comparison of dynamic contour tonometry with Goldmann applanation tonometry
    Kaufmann, C
    Bachmann, LM
    Thiel, MA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) : 3118 - 3121
  • [24] Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    Hoffmann E.M.
    Grus F.-H.
    Pfeiffer N.
    BMC Ophthalmology, 4 (1) : 1 - 7
  • [25] Intraocular pressure elevation after vitrectomy-Goldmann applanation tonometry measures lower intraocular pressure than dynamic contour tonometry
    Baeurle, Sebastian
    Viestenz, Anja
    Seitz, Berthold
    Viestenz, Arne
    OPHTHALMOLOGE, 2022, 119 (SUPPL 1): : 71 - 76
  • [26] Assessment of Factors Affecting the Difference in Intraocular Pressure Measurements Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry
    Wang, Jing
    Cayer, Marie-Michelle
    Descovich, Denise
    Kamdeu-Fansi, Alvine
    Harasymowycz, Paul J.
    Li, Gisele
    Lesk, Mark R.
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 482 - 487
  • [27] Comparison of Goldmann Applanation Tonometry and Dynamic Contour Tonometry in the Measurement of Intraocular Pressure in Eyes with Different Corneal Thicknesses
    Roszkowska, A. M.
    De Grazia, L.
    Cirone, M.
    Ferreri, G.
    OPHTHALMOLOGICA, 2009, 223 (04) : 244 - 249
  • [28] Intraoular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    Schneider, ED
    Grehn, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [29] Dynamic contour tonometry - A new way to assess intraocular pressure in ectatic corneas
    Ozbek, Zeynep
    Cohen, Elisabeth J.
    Hammersmith, Kristin M.
    Rapuano, Christopher J.
    CORNEA, 2006, 25 (08) : 890 - 894
  • [30] Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas
    Kontadakis, George A.
    Pennos, Alexandros
    Pentari, Iro
    Kymionis, George D.
    Pallikaris, Ioannis G.
    Ginis, Harilaos
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2020, 12