PANI-Based Wearable Electrochemical Sensor for pH Sweat Monitoring

被引:67
作者
Mazzara, Francesca [1 ]
Patella, Bernardo [1 ]
D'Agostino, Chiara [1 ]
Bruno, Maria Giuseppina [1 ]
Carbone, Sonia [1 ]
Lopresti, Francesco [1 ]
Aiello, Giuseppe [1 ]
Torino, Claudia [2 ]
Vilasi, Antonio [2 ]
O'Riordan, Alan [3 ]
Inguanta, Rosalinda [1 ]
机构
[1] Univ Palermo, Dept Engn, Appl Phys Chem Lab, Viale Sci, I-90128 Palermo, Italy
[2] CNR, Ist Fisiol Clin IFC, I-89126 Reggio Di Calabria, Italy
[3] Univ Coll Cork, Tyndall Natl Inst, Nanotechnol Grp, Cork T12 R5CP, Ireland
关键词
pH sensor; sweat; polyaniline; wearable sensor; electrochemical sensor; reduced graphene oxide; ASCORBIC-ACID; URIC-ACID; POLYANILINE; GRAPHENE; ELECTRODE; COMPOSITE; NANOCOMPOSITES; CONDUCTIVITY; OPTIMIZATION; MEMBRANE;
D O I
10.3390/chemosensors9070169
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, we are assisting in the exceptional growth in research relating to the development of wearable devices for sweat analysis. Sweat is a biofluid that contains useful health information and allows a non-invasive, continuous and comfortable collection. For this reason, it is an excellent biofluid for the detection of different analytes. In this work, electrochemical sensors based on polyaniline thin films deposited on the flexible substrate polyethylene terephthalate coated with indium tin oxide were studied. Polyaniline thin films were abstained by the potentiostatic deposition technique, applying a potential of +2 V vs. SCE for 90 s. To improve the sensor performance, the electronic substrate was modified with reduced graphene oxide, obtained at a constant potential of -0.8 V vs. SCE for 200 s, and then polyaniline thin films were electrodeposited on top of the as-deposited substrate. All samples were characterized by XRD, SEM, EDS, static contact angle and FT-IR/ATR analysis to correlate the physical-chemical features with the performance of the sensors. The obtained electrodes were tested as pH sensors in the range from 2 to 8, showing good behavior, with a sensitivity of 62.3 mV/pH, very close to a Nernstian response, and a reproducibility of 3.8%. Interference tests, in the presence of competing ions, aimed to verify the selectivity, were also performed. Finally, a real sweat sample was collected, and the sweat pH was quantified with both the proposed sensor and a commercial pH meter, showing an excellent concordance.
引用
收藏
页数:14
相关论文
共 95 条
[81]   Fully Printed Wearable Microfluidic Devices for High-Throughput Sweat Sampling and Multiplexed Electrochemical Analysis [J].
Vinoth, Rajendran ;
Nakagawa, Tatsuo ;
Mathiyarasu, Jayaraman ;
Mohan, A. M. Vinu .
ACS SENSORS, 2021, 6 (03) :1174-1186
[82]   Diffusion profile simulations and enhanced iron sensing in generator-collector mode at interdigitated nanowire electrode arrays [J].
Wahl, Amelie J. C. ;
Seymour, Ian P. ;
Moore, Micheal ;
Lovera, Pierre ;
O'Riordan, Alan ;
Rohan, James F. .
ELECTROCHIMICA ACTA, 2018, 277 :235-243
[83]   Polyaniline (PANi) based electrode materials for energy storage and conversion [J].
Wang, Huanhuan ;
Lin, Jianyi ;
Shen, Ze Xiang .
JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2016, 1 (03) :225-255
[84]   Stretchable gold fiber-based wearable electrochemical sensor toward pH monitoring [J].
Wang, Ren ;
Zhai, Qingfeng ;
Zhao, Yunmeng ;
An, Tiance ;
Gong, Shu ;
Guo, Zhirui ;
Shi, QianQian ;
Yong, Zijun ;
Cheng, Wenlong .
JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (16) :3655-3660
[85]   Engineering Materials for Electrochemical Sweat Sensing [J].
Wang, Zhengyun ;
Shin, Jihoon ;
Park, Jin-Ho ;
Lee, Hakho ;
Kim, Dong-Hwan ;
Liu, Hongfang .
ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (12)
[86]   Reagent free electrochemical-based detection of silver ions at interdigitated microelectrodes using in-situ pH control [J].
Wasiewska, Luiza A. ;
Seymour, Ian ;
Patella, Bernardo ;
Inguanta, Rosalinda ;
Burgess, Catherine M. ;
Duffy, Geraldine ;
O'Riordan, Alan .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 333
[87]   Communication-Polyaniline Electrodeposition on Flexible ITO Substrates and the Effect of Curved Electrochemical Conditions [J].
Wirth, Denise M. ;
Waldman, Laura J. ;
Petty, Makayla ;
LeBlanc, Gabriel .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) :D635-D637
[88]   HYDROGEN-ION METABOLISM [J].
WORTHLEY, LIG .
ANAESTHESIA AND INTENSIVE CARE, 1977, 5 (04) :347-360
[89]   One-pot hydrothermal synthesis of polyaniline nanofibers/reduced graphene oxide nanocomposites and their supercapacitive properties [J].
Xiong, Shanxin ;
Wang, Yuancheng ;
Chu, Jia ;
Wang, Xiaoqin ;
Zhang, Runlan ;
Gong, Ming ;
Wu, Bohua ;
Li, Zhen .
HIGH PERFORMANCE POLYMERS, 2019, 31 (9-10) :1238-1247
[90]   Electrochemical serotonin sensing interface based on double-layered membrane of reduced graphene oxide/polyaniline nanocomposites and molecularly imprinted polymers embedded with gold nanoparticles [J].
Xue, Cheng ;
Wang, Xi ;
Zhu, Wanying ;
Han, Qing ;
Zhu, Chunhong ;
Hong, Junli ;
Zhou, Xuemin ;
Jiang, Huijun .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 :57-63