The impacts of evaluation indices and normalization methods on E-TOPSIS optimization of return vent height for an impinging jet ventilation system

被引:16
作者
Qin, Chao [1 ]
Wu, Shi-Hai [1 ,2 ]
Fang, Hong-Qiang [1 ]
Lu, Wei-Zhen [1 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[2] Cent South Univ, Sch Architecture & Art, Changsha, Peoples R China
关键词
evaluation indices; normalization method; impinging jet ventilation; return vent height; E-TOPSIS; AIR-DISTRIBUTION SYSTEMS; THERMAL COMFORT; STRATIFIED AIR; ENERGY-CONSUMPTION; ENVIRONMENT; ROOM; PERFORMANCE; PREDICTION; OPERATION; SPACES;
D O I
10.1007/s12273-022-0914-z
中图分类号
O414.1 [热力学];
学科分类号
摘要
Stratified air distribution (STRAD) systems have been intensively investigated in recent decades for their energy-saving potential and good indoor air quality performance. However, the evaluation indices used to optimize STRAD systems and the normalization methods for weight calculation vary from one research to another. This study aims to investigate the impacts of evaluation indices on the optimal return vent height of a room cooled by an impinging jet ventilation system (one type of STRAD system). The effects of several widely used normalization methods (i.e., vector normalization, sum normalization, min-max normalization, and no normalization) on indices weights are investigated. The evaluation indices are cooling coil load (Q(coil)), energy-saving potential (Delta Q(coil)), mean age of air (MAA), CO2 mass fraction, temperature difference between the head and ankles (Delta T0.1-1.1), predicted mean vote (PMV), predicted percentage of dissatisfied (PPD), and draft rate (DR). The multi-criteria optimization method is the entropy-based technique for order preference by similarity to ideal solution (E-TOPSIS). As a result, the min-max normalization method evens the weight of each index and results in unreasonable relative weights. Consequently, the raw matrix (i.e., the normalization is omitted) is suggested for weight calculation. Among these indices, Delta T0.1-1.1 and PPD play critical roles. Without Delta T0.1-1.1, the optimal return vent height changes from mid-level to near-floor, while without PPD, it changes to near-ceiling. Another important result is that the Q(coil) plays the most trivial role, followed by MAA and DR. Therefore, the optimal return vent height is not determined by energy-saving performance but by performances of thermal comfort.
引用
收藏
页码:2081 / 2095
页数:15
相关论文
共 62 条
[1]   A numerical study on the effects of exhaust locations on energy consumption and thermal environment in an office room served by displacement ventilation [J].
Ahmed, Ahmed Qasim ;
Gao, Shian ;
Kareem, Ali Khaleel .
ENERGY CONVERSION AND MANAGEMENT, 2016, 117 :74-85
[2]   Ventilation and energy performance of partitioned indoor spaces under mixing and displacement ventilation [J].
Ahn, Hyeunguk ;
Rim, Donghyun ;
Lo, L. James .
BUILDING SIMULATION, 2018, 11 (03) :561-574
[3]  
[Anonymous], 2005, International Organization for Standardization ISO 11269-2. Soil quality: determination of the effects of pollutants on soil flora -Part 2: Effects of chemicals on the emergence and growth of higher plants, DOI DOI 10.1016/J.SOILDYN.2004.11.005
[4]  
[Anonymous], 2014, 50034 GB
[5]  
[Anonymous], 2010, THERMAL ENV CONDITIO
[6]  
[Anonymous], 507362012 GB
[7]  
ASHRAE, 2010, ANSI/ASHRAE Standard 116-2010, V2010
[8]   The SPA-TOPSIS-Based Evaluating Approach on Thermal Sensation Model at Different Vane Angles in UFAD-DV System [J].
Bai, Yan ;
Wan, Taocheng .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2021, 46 (02) :1787-1802
[9]   Effects of ventilation on the indoor spread of COVID-19 [J].
Bhagat, Rajesh K. ;
Davies Wykes, M. S. ;
Dalziel, Stuart B. ;
Linden, P. F. .
JOURNAL OF FLUID MECHANICS, 2020, 903