Diagnostic utility of endoscopic ultrasonography-elastography in the evaluation of solid pancreatic masses: a meta-analysis and systematic review

被引:27
|
作者
Lu, Yi [1 ]
Chen, Lu [2 ]
Li, Chujun [1 ]
Chen, Honglei [1 ]
Chen, Jinhua [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 6, Digest Endoscopy Ctr, 26 Yuancun Erheng Rd, Guangzhou 510655, Guangdong, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Dept Gastroenterol, Ruijin Hosp,Digest Endoscopy Ctr, Shanghai, Peoples R China
关键词
endoscopic ultrasonography; elastography; contrast-enhanced EUS; EUS-guided fine needle aspiration; pancreatic masses; REAL-TIME ELASTOGRAPHY; ULTRASOUND-ELASTOGRAPHY; EUS-ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; STRAIN RATIO; LESIONS; ACCURACY; FNA; MULTICENTER; ADENOCARCINOMA;
D O I
10.11152/mu-987
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: The accuracy for endoscopic ultrasonography-elastography ( EUS-EG) in the evaluation of solid pancreatic masses varies greatly and the pooled results have not been updated since 2013. Also, there still lack a comprehensive comparison among EUS-EG, contrast-enhanced EUS (CE-EUS), and EUS-guided fine needle aspiration (EUS-FNA). Material and methods: A thorough search was made for diagnostic trials investigating the role of EUS-EG in solid pancreatic masses. Meta-Disc was used to calculate the pooled sensitivity, specificity, diagnostic odds ratio and summary receiver operator characteristics. Results: Finally, 17 studies (1537 patients, 1544 lesions) were selected. The pooled sensitivity and specificity for qualitative methods were 0.97 (95% CI, 0.95-0.99) and 0.67 (95% CI, 0.59-0.74), respectively; the pooled sensitivity and specificity for strain histograms were 0.97 (95% CI, 0.95-0.98) and 0.67(95% CI, 0.61-0.73), respectively; the pooled sensitivity and specificity for strain ratio were 0.98 (95% CI, 0.96-0.99) and 0.62 (95% CI, 0.56-0.68), respectively; the pooled sensitivity and specificity for CE-EUS were 0.90 (95% CI, 0.83-0.95) and 0.76 (95% CI, 0.67-0.84), respectively; the pooled sensitivity and specificity for EUS-FNA were 0.84 (95% CI, 0.77-0.90) and 0.96(95% CI, 0.88-1.00), respectively. Conclusion: EUS-EG is reliable for distinguishing solid pancreatic masses; the sensitivity and specificity for different diagnostic methods were very close. Both EUS-EG and CE-EUS can be valuable complementary supplements for EUS-FNA.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 50 条
  • [21] Diagnostic value of endoscopic ultrasound for detecting pancreatic neuroendocrine tumors: A systematic review and meta-analysis
    Chen, Yang
    Huang, Fei
    Fan, Youwen
    Li, Dong
    Tao, Qiang
    Tang, Di
    Deng, Liang
    Ma, Chao
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2022, 363 (06) : 511 - 518
  • [22] Diagnostic performance of elastography for breast non-mass lesions: A systematic review and meta-analysis
    Hong, Shaofu
    Li, Weiyue
    Gao, Wenjing
    Liu, Mengmeng
    Song, Di
    Dong, Yinghui
    Xu, Jinfeng
    Dong, Fajin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 144
  • [23] Combination of shear-wave elastography with ultrasonography for detection of breast cancer and reduction of unnecessary biopsies: a systematic review and meta-analysis
    Park, Sun-young
    Kang, Bong Joo
    ULTRASONOGRAPHY, 2021, 40 (03) : 318 - 332
  • [24] Clinical utility of ultrasonography imaging in musculoskeletal conditions: A Systematic review and Meta-analysis
    Shaikh, Summaiya Zareen
    Tejashree, Dabholkar
    Ajit, Dabholkar
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (03) : 285 - 294
  • [25] Effect of the number of passes on diagnostic performance of EUS fi ne-needle biopsy of solid pancreatic masses: a systematic review and meta-analysis
    Chalhoub, Jean M.
    Hawa, Fadi
    Grantham, Tyler
    Lester, Janice
    Carpenter, Eileen S.
    Mendoza-Ladd, Antonio
    Wani, Sachin
    Machicado, Jorge D.
    GASTROINTESTINAL ENDOSCOPY, 2024, 100 (04) : 595 - 604.e8
  • [26] Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis
    Salameh, Jean-Paul
    McInnes, Matthew D. F.
    McGrath, Trevor A.
    Salameh, Gilles
    Schieda, Nicola
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (04) : W100 - W105
  • [27] Comparison of endoscopic ultrasonography and magnifying endoscopy for assessment of the invasion depth of shallow gastrointestinal neoplasms: a systematic review and meta-analysis
    Tao, Zhang
    Yan, Chen
    Zhao, He
    Tsauo, Jiawei
    Zhang, Xiaowu
    Qiu, Bing
    Zhao, Yanqing
    Li, Xiao
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (12): : 4923 - 4933
  • [28] Diagnostic and prognostic value of carcinoembryonic antigen in pancreatic cancer: a systematic review and meta-analysis
    Meng, Qingcai
    Shi, Si
    Liang, Chen
    Liang, Dingkong
    Xu, Wenyan
    Ji, Shunrong
    Zhang, Bo
    Ni, Quanxing
    Xu, Jin
    Yu, Xianjun
    ONCOTARGETS AND THERAPY, 2017, 10 : 4591 - 4598
  • [29] Diagnostic Performance and Accuracy of the 3 Interpreting Methods of Breast Strain Elastography: A Systematic Review and Meta-analysis
    Barr, Richard G.
    De Silvestri, Annalisa
    Scotti, Valeria
    Manzoni, Federica
    Rebuffi, Chiara
    Capittini, Cristina
    Tinelli, Carmine
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (06) : 1397 - 1404
  • [30] Diagnostic accuracy of cervical elastography in predicting preterm delivery A systematic review and meta-analysis
    Wang, Bo
    Zhang, Yong
    Chen, Shuangshuang
    Xiang, Xiaowei
    Wen, Juan
    Yi, Mei
    He, Baiyun
    Hu, Bing
    MEDICINE, 2019, 98 (29)