A pressure-tunable, series-coupled column ensemble was used with atmospheric pressure air as carrier gas for the vacuum-outlet GC analysis of 42 volatile and semivolatile organic compounds commonly encountered as indoor air pollutants. Separation strategies applicable to a field-portable instrument that will employ a dual-stage preconcentrator and a microsensor array as the detector were developed, where coelution of certain analytes can be tolerated. The capillary column ensemble consists of a 4.5-m segment of nonpolar dimethyl polysiloxane followed by a 7.5-m segment of polar trifluoropropylmethyl polysiloxane. Good long-term thermal stability of the column ensemble was observed for continuous operation in air at temperatures up to 210 degreesC. A computer-driven pressure controller at the column junction point is used to adjust vapor retention for specified sets of target compounds. The compounds were divided into two groups according to retention order, and high-speed analysis conditions were determined for the two groups individually as well as for the entire mixture. The earlier eluting group of 21 compounds was analyzed isothermally at 30 degreesC in about 160 s using a single, on-the-fly junction; point pressure change during the separation. The later eluting group of 21 compounds was analyzed in about 200 s with temperature programming and a constant (tuned) junction-point pressure. The entire mixture was analyzed in about 400 s using a two-step temperature program and a three-step pressure program, with minimal overlap in eluting peaks. Separations are adequate for analysis by a sensor array capable of discriminating among small groups of coeluting vapors on the basis of their response patterns.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 38 条
  • [1] SEPARATION WINDOW DIAGRAMS FOR HIGH-SPEED GC
    AKARD, M
    SACKS, R
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2733 - 2737
  • [2] PRESSURE-TUNABLE SELECTIVITY FOR HIGH-SPEED GAS-CHROMATOGRAPHY
    AKARD, M
    SACKS, R
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3036 - 3041
  • [3] [Anonymous], 1993, Journal of Indoor Air, DOI DOI 10.1111/J.1600-0668.1993.T01-1-00002.X
  • [4] BATTERMAN S, 1995, BIOAEROSOLS, P246
  • [5] BENICKA E, 1991, J MIKROCHIM ACTA, V3, P1
  • [6] CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR - A REVIEW
    BROWN, SK
    SIM, MR
    ABRAMSON, MJ
    GRAY, CN
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02): : 123 - 134
  • [7] Burton B. T., 1997, INDOOR AIR POLLUTION, P127
  • [8] Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors
    Cai, QY
    Park, J
    Heldsinger, D
    Hsieh, MD
    Zellers, ET
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) : 121 - 130
  • [9] GAS-CHROMATOGRAPHIC COLUMNS WITH ADJUSTABLE SEPARATION CHARACTERISTICS
    DEANS, DR
    SCOTT, I
    [J]. ANALYTICAL CHEMISTRY, 1973, 45 (07) : 1137 - 1141
  • [10] Novel column heater for fast capillary gas chromatography
    Ehrmann, EU
    Dharmasena, HP
    Carney, K
    Overton, EB
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (12) : 533 - 539