Improved Voltammetric Determination of Kynurenine at the Nafion Covered Glassy Carbon Electrode - Application in Samples Delivered from Human Cancer Cells

被引:5
作者
Sadok, Ilona [1 ]
Tyszczuk-Rotko, Katarzyna [2 ]
Mroczka, Robert [3 ]
Kozak, Jedrzej [2 ]
Staniszewska, Magdalena [1 ]
机构
[1] John Paul II Catholic Univ Lublin, Fac Sci & Hlth, Ctr Interdisciplinary Res, Lab Separat & Spect Method Applicat, Konstantynow 1J, PL-20708 Lublin, Poland
[2] Marie Curie Sklodowska Univ, Fac Chem, Inst Chem Sci, Lublin, Poland
[3] John Paul II Catholic Univ, Ctr Interdisciplinary Res, Fac Sci & Hlth, Lab Xray Opt, Lublin, Poland
来源
INTERNATIONAL JOURNAL OF TRYPTOPHAN RESEARCH | 2021年 / 14卷
关键词
Kynurenine; tryptophan metabolites analysis; kynurenine pathway; Nafion modified electrodes; adsorptive stripping voltammetry; cancer cells; STRIPPING VOLTAMMETRY; FILM ELECTRODE; TRYPTOPHAN; SENSOR; METABOLITES; GRAPHENE; PATHWAY; NANOPARTICLES; ADSORPTION; COMPOSITE;
D O I
10.1177/11786469211023468
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Nowadays, development of analytical methods responding to a need for rapid and accurate determination of human metabolites is highly desirable. Herein, an electrochemical method employing a Nafion-coated glassy carbon electrode (Nafion/GCE) has been developed for reliable determination of kynurenine (a key tryptophan metabolite) using a differential pulse adsorptive stripping voltammetry. To our knowledge, this is the first analytical method to allow for kynurenine determination at the Nafion-coated electrode. The methodology involves kynurenine pre-concentration in 0.1 M H2SO4 in the Nafion film at the potential of +0.5 V and subsequent stripping from the electrode by differential pulse voltammetry. Under optimal conditions, the sensor can detect 5 nM kynurenine (for the accumulation time of 60 seconds), but the limit of detection can be easily lowered to 0.6 nM by prolonging the accumulation time to 600 seconds. The sensor shows sensitivity of 36.25 mu A mu M(-1)cm(-2) and 185.50 mu A mu M(-1)cm(-2) for the accumulation time of 60 and 600 seconds, respectively. The great advantage of the proposed method is easy sensor preparation, employing drop coating method, high sensitivity, short total analysis time, and no need for sample preparation. The method was validated for linearity, precision, accuracy (using a high-performance liquid chromatography), selectivity (towards tryptophan metabolites and different amino acids), and recovery. The comprehensive microscopic and electrochemical characterization of the Nafion/GCE was also conducted with different methods including atomic force microscopy (AFM), optical profilometry, time-of-flight secondary ion mass spectrometry (TOF-SIMS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The method has been applied with satisfactory results for determination of kynurenine concentration in a culture medium collected from the human ovarian carcinoma cells SK-OV-3 and to measure IDO enzyme activity in the cancer cell extracts.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Nafion-Titanium (IV) Oxide-Graphene Modified Glassy Carbon Electrode (GCE) Based Electrochemical Sensor for the Voltammetric Determination of the β-blocker Bisoprolol Fumarate
    Kocak, Berna
    Ipek, Yeliz
    ANALYTICAL LETTERS, 2023, 56 (10) : 1619 - 1631
  • [22] Simultaneous and selective determination of purine metabolites in human urine samples using nanocomposite modified glassy carbon electrode
    Liu, Xiaojian
    Dai, Jindong
    Shen, Jian
    Zhu, Dongwei
    Rajalakshmi, Kanagaraj
    Muthusamy, Selvaraj
    Kanagaraj, Thangamani
    Kannan, Palanisamy
    JOURNAL OF MOLECULAR LIQUIDS, 2024, 411
  • [23] Voltammetric determination of acetaminophen in pharmaceutical preparations and human urine using glassy carbon paste electrode modified with reduced graphene oxide
    Farag, Amir Shaaban
    ANALYTICAL SCIENCES, 2022, 38 (09) : 1213 - 1220
  • [24] Sensitive voltammetric determination of riboflavin in pharmaceutical and biological samples using FSN-Zonyl-Nafion modified carbon paste electrode
    Stefanov, Cristina
    Negut, Catalina Cioates
    Gugoasa, Livia Alexandra Dinu
    van Staden, Jacobus Frederick
    MICROCHEMICAL JOURNAL, 2020, 155
  • [25] Highly sensitive square wave voltammetric method for determination of brucine in artificial urine samples based on choline chloride modified glassy carbon electrode
    Biya, Semira
    Negash, Negussie
    Hailu, Tesfu
    Tesfaye, Gizaw
    Yaya, Estifanose Ele
    HELIYON, 2023, 9 (03)
  • [26] Electrochemical Sensor Based on TiO2 Nanoparticles/Nafion Biocompatible Film Modified Glassy Carbon Electrode for Carbamazepine Determination in Pharmaceutical and Urine Samples
    Tarahomi, Somayeh
    Rounaghi, Gholam Hossein
    Zavar, Mohammad Hossein Arbab
    Daneshvar, Leili
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (16) : B946 - B952
  • [27] Sensitive voltammetric determination of testosterone in pharmaceuticals and human urine using a glassy carbon electrode in the presence of cationic surfactant
    Levent, Abdulkadir
    Altun, Ahmet
    Yardim, Yavuz
    Senturk, Zuhre
    ELECTROCHIMICA ACTA, 2014, 128 : 54 - 60
  • [28] Electrochemistry and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with a Nafion/TiO2-graphene composite film
    Yang Fan
    Jin-Hang Liu
    Hai-Ting Lu
    Qin Zhang
    Microchimica Acta, 2011, 173 : 241 - 247
  • [29] Square wave voltammetric determination of quercetin in wine and fruit juice samples at poly (safranine O) modified glassy carbon electrode
    Tesfaye, Gizaw
    Hailu, Tesfu
    Ele, Estifanos
    Negash, Negussie
    Tessema, Merid
    SENSING AND BIO-SENSING RESEARCH, 2021, 34
  • [30] Application of Glassy Carbon Electrode Modified with Co3O4 Nanoparticles for Voltammetric Determination of Folic Acid
    Kondori, Tahere
    Akbarzadeh-Torbati, Niloufar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (09): : 1211 - 1221