Spectral Analysis Methods with Continuous Wavelet Transform to Characterize Media Periodicity Using Backscattered and Simulated Ultrasound Signals

被引:0
作者
Machado, Christiano Bittencourt [1 ,2 ]
Meziri, Mahmoud [3 ]
Pereira, Wagner Coelho de A. [4 ]
Cortela, Guillermo [2 ]
机构
[1] Univ Estacio Sa, Biomed Ultrasound Lab, Rua Eduardo Luiz Gomes 134, BR-24020340 Niteroi, RJ, Brazil
[2] Univ La Republ, Inst Fis, Fac Ciencias, Igua 4225 & Mataojo, Montevideo 11400, Uruguay
[3] Univ Badji Mokhtar, LM2S, Annaba 23000, Algeria
[4] Univ Fed Rio de Janeiro, COPPE, Biomed Engn Program, Av Horacio Macedo,Cidade Univ 2030-101,Block H, BR-21941450 Rio de Janeiro, RJ, Brazil
来源
XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL. 2 | 2019年 / 70卷 / 02期
关键词
Ultrasound; Wavelets; Mean scatterer spacing;
D O I
10.1007/978-981-13-2517-5_69
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed at applying spectral methods and CWT in the periodicity characterization in simulated/backscattered A-mode ultrasound signals. The experimental setup used a transducer (7.5 MHz) on a pulse-echo configuration. A copper-rods phantom modeled a periodic scatterers pattern (diameter = 0.5 mm, spacing = 2.5 mm). The transducer was translated parallel to the phantom to collect signals. A-mode 7.5-MHz signals were also simulated using a numerical model with contributions from regular (MSS = 1 mm) and diffuse scatterers, with several levels of noises and jitters (variability on the expected scatterer positions). Experimental and simulated signals were processed with the spectral autocorrelation (SAC), singular spectrum analysis (SSA) and the quadratic transformation (Simon's method) for MSS estimation, as well as the continuous wavelet transform with two mother-wavelets. MSS distributions are not similar in many noise-jitter situations, or when comparing the performance between two methods (p < 0.05). SAC was able to better characterize scatterer spacing. SIMON and CWT presented modes near 2.5 mm and 3.5 mm (the MSS and the diagonal distance of two rods). SSA may detect rods thicknesses (0.5 mm). CWT would fit for locating scatterer position.
引用
收藏
页码:455 / 459
页数:5
相关论文
共 7 条
[1]   Can early hepatic fibrosis stages be discriminated by combining ultrasonic parameters? [J].
Bouzitoune, Razika ;
Meziri, Mahmoud ;
Machado, Christiano Bittencourt ;
Padilla, Frederic ;
de Albuquerque Pereira, Wagner Coelho .
ULTRASONICS, 2016, 68 :120-126
[2]  
Ghoshal G., 2013, Quantitative Ultrasound in Soft Tissues
[3]   Characterization of in vitro healthy and pathological human liver tissue periodicity using backscattered ultrasound signals [J].
Machado, Christiano Bittencourt ;
Coelho De Albuquerque Pereira, Wagner ;
Meziri, Mahmoud ;
Laugier, Pascal .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (05) :649-657
[4]  
Percival D., 2000, CA ST PR MA
[5]   Performance of ultrasound echo decomposition using singular spectrum analysis [J].
Pereira, WCD ;
Maciel, CD .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (09) :1231-1238
[6]   Wavelet transforms in estimating scatterer spacing from ultrasound echoes [J].
Tang, XY ;
Abeyratne, UR .
ULTRASONICS, 2000, 38 (1-8) :688-692
[7]   Ultrasonic evaluation of microwave-induced thermal lesions based on wavelet analysis of mean scatterer spacing [J].
Zhou, Zhuhuang ;
Sheng, Lei ;
Wu, Shuicai ;
Yang, Chunlan ;
Zeng, Yi .
ULTRASONICS, 2013, 53 (07) :1325-1331