Automated body volume acquisitions from 3D structured-light scanning

被引:8
作者
Chiu, Chuang-Yuan [1 ]
Pease, David L. [2 ]
Fawkner, Samantha [3 ]
Sanders, Ross H. [4 ]
机构
[1] Sheffield Hallam Univ, Ctr Sports Engn Res, Broomgrove Rd, Sheffield S10 2NA, S Yorkshire, England
[2] Australian Inst Sport, Movement Sci, Canberra, ACT, Australia
[3] Univ Edinburgh, Inst Sport Phys Educ & Hlth Sci, Edinburgh, Midlothian, Scotland
[4] Univ Sydney, Fac Hlth Sci, Sydney, NSW, Australia
关键词
Volumetric analysis; Segmental volumes; 3D structured-light scanning; Model fitting; LYMPHEDEMA; ADULTS; SHAPE; RELIABILITY; PARAMETERS; EQUATIONS; VALIDITY; SCANS;
D O I
10.1016/j.compbiomed.2018.07.016
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Whole-body volumes and segmental volumes are highly related to the health and medical condition of individuals. However, the traditional manual post-processing of raw 3D scanned data is time-consuming and needs technical expertise. The purpose of this study was to develop bespoke software for obtaining whole-body volumes and segmental volumes from raw 3D scanned data automatically and to establish its accuracy and reliability. The bespoke software applied Stitched Puppet model fitting techniques to deform template models to fit the 3D raw scanned data to identify the segmental endpoints and determine their locations. Finally, the bespoke software used the location information of segmental endpoints to set segmental boundaries on the reconstructed meshes and to calculate body volume. The whole-body volumes and segmental volumes (head & neck, torso, arms, and legs) of 29 participants processed by the traditional manual operation were regarded as the references and compared to the measurements obtained with the bespoke software using the infra-method and intermethod relative technical errors of measurement. The results showed that the errors in whole-body volumes and most segmental volumes acquired from the bespoke software were less than 5%. Overall, the bespoke software developed in this study can complete the post-processing tasks without any technical expertise, and the obtained whole-body volumes and segmental volumes can achieve good accuracy for some applications in health and medicine.
引用
收藏
页码:112 / 119
页数:8
相关论文
共 41 条
  • [11] Hani A. F. M., 2009, ASSESSMENT ULCER WOU, P243
  • [12] Automatic data segmentation for geometric feature extraction from unorganized 3-D coordinate points
    Huang, JB
    Menq, CH
    [J]. IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2001, 17 (03): : 268 - 279
  • [13] Screened Poisson Surface Reconstruction
    Kazhdan, Michael
    Hoppe, Hugues
    [J]. ACM TRANSACTIONS ON GRAPHICS, 2013, 32 (03):
  • [14] RISK OF LYMPHEDEMA FOLLOWING THE TREATMENT OF BREAST-CANCER
    KISSIN, MW
    DELLAROVERE, GQ
    EASTON, D
    WESTBURY, G
    [J]. BRITISH JOURNAL OF SURGERY, 1986, 73 (07) : 580 - 584
  • [15] Handheld 3-D Scanning with Automatic Multi-View Registration Based on Visual-Inertial Navigation
    Kleiner, Bernhard
    Munkelt, Christoph
    Thorhallsson, Torfi
    Notni, Gunther
    Kuehmstedt, Peter
    Schneider, Urs
    [J]. INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2014, 8 (04) : 313 - 325
  • [16] Efficacy of thigh volume ratios assessed via stereovision body imaging as a predictor of visceral adipose tissue measured by magnetic resonance imaging
    Lee, Jane J.
    Freeland-Graves, Jeanne H.
    Pepper, M. Reese
    Yu, Wurong
    Xu, Bugao
    [J]. AMERICAN JOURNAL OF HUMAN BIOLOGY, 2015, 27 (04) : 445 - 457
  • [17] Segment inertial parameters of Korean adults estimated from three-dimensional body laser scan data
    Ma, Yanzhao
    Kwon, Junghoon
    Mao, Zhihong
    Lee, Kunwoo
    Li, Linlin
    Chung, Hayoung
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2011, 41 (01) : 19 - 29
  • [18] Nonlinear regression equations for segmental mass-inertial characteristics of Korean adults estimated using three-dimensional range scan data
    Ma, Yanzhao
    Lee, Kunwoo
    Li, Linlin
    Kwon, Junghoon
    [J]. APPLIED ERGONOMICS, 2011, 42 (02) : 297 - 308
  • [19] Mirtich Brian, 1996, J Graph Tools, V1, P31, DOI DOI 10.1080/10867651.1996.10487458
  • [20] Muralidhara D., 2015, INTEGR OBES DIABETES, P26