Automated body volume acquisitions from 3D structured-light scanning

被引:8
作者
Chiu, Chuang-Yuan [1 ]
Pease, David L. [2 ]
Fawkner, Samantha [3 ]
Sanders, Ross H. [4 ]
机构
[1] Sheffield Hallam Univ, Ctr Sports Engn Res, Broomgrove Rd, Sheffield S10 2NA, S Yorkshire, England
[2] Australian Inst Sport, Movement Sci, Canberra, ACT, Australia
[3] Univ Edinburgh, Inst Sport Phys Educ & Hlth Sci, Edinburgh, Midlothian, Scotland
[4] Univ Sydney, Fac Hlth Sci, Sydney, NSW, Australia
关键词
Volumetric analysis; Segmental volumes; 3D structured-light scanning; Model fitting; LYMPHEDEMA; ADULTS; SHAPE; RELIABILITY; PARAMETERS; EQUATIONS; VALIDITY; SCANS;
D O I
10.1016/j.compbiomed.2018.07.016
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Whole-body volumes and segmental volumes are highly related to the health and medical condition of individuals. However, the traditional manual post-processing of raw 3D scanned data is time-consuming and needs technical expertise. The purpose of this study was to develop bespoke software for obtaining whole-body volumes and segmental volumes from raw 3D scanned data automatically and to establish its accuracy and reliability. The bespoke software applied Stitched Puppet model fitting techniques to deform template models to fit the 3D raw scanned data to identify the segmental endpoints and determine their locations. Finally, the bespoke software used the location information of segmental endpoints to set segmental boundaries on the reconstructed meshes and to calculate body volume. The whole-body volumes and segmental volumes (head & neck, torso, arms, and legs) of 29 participants processed by the traditional manual operation were regarded as the references and compared to the measurements obtained with the bespoke software using the infra-method and intermethod relative technical errors of measurement. The results showed that the errors in whole-body volumes and most segmental volumes acquired from the bespoke software were less than 5%. Overall, the bespoke software developed in this study can complete the post-processing tasks without any technical expertise, and the obtained whole-body volumes and segmental volumes can achieve good accuracy for some applications in health and medicine.
引用
收藏
页码:112 / 119
页数:8
相关论文
共 41 条
  • [1] Current Status of Body Composition Assessment in Sport Review and Position Statement on Behalf of the Ad Hoc Research Working Group on Body Composition Health and Performance, Under the Auspices of the I.O.C. Medical Commission
    Ackland, Timothy R.
    Lohman, Timothy G.
    Sundgot-Borgen, Jorunn
    Maughan, Ronald J.
    Meyer, Nanna L.
    Stewart, Arthur D.
    Mueller, Wolfram
    [J]. SPORTS MEDICINE, 2012, 42 (03) : 227 - 249
  • [2] Chiu C.-Y., 2016, ERGONOMICS, P1
  • [3] Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods
    Chromy, Adam
    Zalud, Ludek
    Dobsak, Petr
    Suskevic, Igor
    Mrkvicova, Veronika
    [J]. SPRINGERPLUS, 2015, 4 : 1 - 15
  • [4] Collins J., 2006, VOLUMETRIC ANAL HUMA, P1
  • [5] D'Apuzzo N., 2009, Optical 3-D measurement techniques, VIX, P2
  • [6] Volumetric Differences in Body Shape Among Adults With Differing Body Mass Index Values: An Analysis Using Three-Dimensional Body Scans
    Daniell, Nathan
    Olds, Tim
    Tomkinson, Grant
    [J]. AMERICAN JOURNAL OF HUMAN BIOLOGY, 2014, 26 (02) : 156 - 163
  • [7] Technical note: Criterion validity of whole body surface area equations: A comparison using 3D laser scanning
    Daniell, Nathan
    Olds, Timothy
    Tomkinson, Grant
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2012, 148 (01) : 148 - 155
  • [8] Computer-aided alignment of castings and machining optimization
    Gessner, Andrzej
    Staniek, Roman
    Bartkowiak, Tomasz
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2015, 229 (03) : 485 - 492
  • [9] Scan posture definition and hip girth measurement: the impact on clothing design and body scanning
    Gill, Simeon
    Parker, Christopher J.
    [J]. ERGONOMICS, 2017, 60 (08) : 1123 - 1136
  • [10] Girardeau-Montaut D., 2017, CloudCompare (version 2.10alpha)