Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures

被引:46
作者
Kallinen, Linda M. [1 ]
Hauser, Robert G. [1 ]
Tang, Chuen [1 ]
Melby, Daniel P. [1 ]
Almquist, Adrian K. [1 ]
Katsiyiannis, William T. [1 ]
Gornick, Charles C. [1 ]
机构
[1] Minneapolis Heart Inst Fdn, Minneapolis, MN USA
关键词
Audible alert; Complications; Follow-up; Implantable cardioverter-defibrillator; Lead failure; Reliability; Sprint Fidelis; FAILURE; RISK;
D O I
10.1016/j.hrthm.2010.05.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The Medtronic Sprint Fidelis high-voltage implantable cardioverter-defibrillator (ICD) lead is prone to fracture. The majority of fractures involve the pace-sense (P/S) conductors and may result in multiple inappropriate shocks. The Medtronic lead integrity alert (LIA) algorithm was designed to improve early detection of transient P/S conductor fractures and to decrease the incidence and number of inappropriate shocks. OBJECTIVE The purpose of this prospective single-center study was to assess the effectiveness of the LIA algorithm for warning patients of an impending Sprint Fidelis P/S conductor fracture and for decreasing the incidence and number of inappropriate shocks. METHODS The study population included all patients who had Sprint Fidelis leads and Medtronic ICD pulse generators that were implanted and followed at the Minneapolis Heart Institute. Patients were evaluated in the clinic every 3 to 4 months or by remote monitoring using the Medtronic CareLink system. When the LIA algorithm was released in August 2008, the RAMware was downloaded to the pulse generator of all patients with the Sprint Fidelis lead. Patients and family members received educational materials and were given a demonstration of the audible alerts. RESULTS Between October 2004 and January 2010, 52 (11.3%) of 461 Sprint Fidelis leads failed in the study population. Inappropriate shocks were the first sign of lead failure in 18 (69%) of the 26 patients who did not have the LIA compared to 4 (17%) of 23 patients who had the LIA (P = .0004). Patients who experienced inappropriate shocks without the LIA received an average of 13.2 +/- 13.6 inappropriate shocks (range 2-54) versus 3.0 +/- 2.0 inappropriate shocks (range 2-6) in patients who had the LIA (P = .017). The audible alert was effective in 70% (16/23) and 35% (6/17) of patients with and without the LIA, respectively, whose alerts were programmed ON (P = .053). Overall, 8 (32%) of 25 patients whose audible alerts were triggered did not immediately hear or recognize the tone. CONCLUSION The LIA appears to be an effective method for detecting most Sprint Fidelis lead fractures and for decreasing the incidence and number of inappropriate shocks. However, a better method for alerting patients and caregivers is needed.
引用
收藏
页码:1048 / 1055
页数:8
相关论文
共 19 条
  • [1] [Anonymous], 2007, URG MED DEV INF SPRI
  • [2] Beukema RJ, 2010, NETH HEART J, V18, P12
  • [3] Multiple ICD Discharges Associated with Lead Fracture Without Triggering of High Impedance Alert
    Donaldson, David M.
    Singh, Jagmeet P.
    Heist, E. Kevin
    Mela, Theofanie
    Ruskin, Jeremy N.
    Das, Saumya
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (04): : 543 - 546
  • [4] Accelerating risk of Fidelis lead fracture
    Farwell, David
    Green, Martin S.
    Lemery, Robert
    Gollob, Michael H.
    Birnie, David H.
    [J]. HEART RHYTHM, 2008, 5 (10) : 1375 - 1379
  • [5] Time-Dependent Risk of Fidelis Lead Failure
    Faulknier, Brett A.
    Traub, Darren M.
    Aktas, Mehmet K.
    Aguila, Alian
    Rosero, Spencer
    Daubert, James P.
    Hall, Burr
    Shah, Abrar
    Taylor, Sarah
    McNitt, Scott
    Moss, Arthur J.
    Zareba, Wojciech
    Huang, David T.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (01) : 95 - 99
  • [6] Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure
    Gunderson, BD
    Gillberg, JM
    Wood, MA
    Vijayaraman, P
    Shepard, RK
    Elenbogen, KA
    [J]. HEART RHYTHM, 2006, 3 (02) : 155 - 162
  • [7] An algorithm to predict implantable cardioverter-defibrillator lead failure
    Gunderson, BD
    Patel, AS
    Bounds, CA
    Shepard, RK
    Wood, MA
    Ellenbogen, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (09) : 1898 - 1902
  • [8] Effect of programmed number of intervals to detect ventricular fibrillation on implantable cardioverter-defibrillator aborted and unnecessary shocks
    Gunderson, Bruce D.
    Abeyratne, Athula I.
    Olson, Walter H.
    Swerdlow, Charles D.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (02): : 157 - 165
  • [9] Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead
    Hauser, Robert G.
    Kallinen, Linda M.
    Almquist, Adrian K.
    Gornick, Charles C.
    Katsiyiannis, William T.
    [J]. HEART RHYTHM, 2007, 4 (07) : 892 - 896
  • [10] Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure
    Hauser, Robert G.
    Hayes, David L.
    [J]. HEART RHYTHM, 2009, 6 (05) : 605 - 610