A high-performance 4 nV (√Hz)-1 analog front-end architecture for artefact suppression in local field potential recordings during deep brain stimulation

被引:10
作者
Petkos, Konstantinos [1 ,2 ]
Guiho, Thomas [3 ]
Degenaar, Patrick [4 ]
Jackson, Andrew [3 ]
Brown, Peter [5 ,6 ]
Denison, Timothy [5 ]
Drakakis, Emmanuel M. [1 ,2 ]
机构
[1] Imperial Coll London, Dept Bioengn, London, England
[2] Imperial Coll London, Ctr Neurotechnol, London, England
[3] Newcastle Univ, Inst Neurosci, Newcastle Upon Tyne, Tyne & Wear, England
[4] Newcastle Univ, Sch Engn, Newcastle Upon Tyne, Tyne & Wear, England
[5] Univ Oxford, MRC, Brain Network Dynam Unit, Oxford, England
[6] Univ Oxford, Nuffield Dept Clin Neurosci, Oxford, England
基金
英国工程与自然科学研究理事会;
关键词
DBS; artefact suppression; high-performance analog front-end; LFP (IE x G) bioinstrumentation; analog filtering; TRANSCRANIAL MAGNETIC STIMULATION; PRIMARY MOTOR CORTEX; NEUROMODULATION DEVICE; OSCILLATORY ACTIVITIES; STIMULUS ARTIFACT; REMOVAL; SYNCHRONIZATION; NETWORKS; NEURONS; DESIGN;
D O I
10.1088/1741-2552/ab2610
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Recording of local field potentials (LFPs) during deep brain stimulation (DBS) is necessary to investigate the instantaneous brain response to stimulation, minimize time delays for closed-loop neurostimulation and maximise the available neural data. To our knowledge, existing recording systems lack the ability to provide artefact-free high-frequency (>100 Hz) LFP recordings during DBS in real time primarily because of the contamination of the neural signals of interest by the stimulation artefacts. Approach. To solve this problem, we designed and developed a novel, low-noise and versatile analog front-end (AFE) that uses a high-order (8th) analog Chebyshev notch filter to suppress the artefacts originating from the stimulation frequency. After defining the system requirements for concurrent LFP recording and DBS artefact suppression, we assessed the performance of the realised AFE by conducting both in vitro and in vivo experiments using unipolar and bipolar DBS (monophasic pulses, amplitude ranging from 3 to 6 V peak-to-peak, frequency 140 Hz and pulse width 100 mu s). A full performance comparison between the proposed AFE and an identical AFE, equipped with an 8th order analog Bessel notch filter, was also conducted. Main results. A high-performance, 4 nV (root Hz)(-1) AFE that is capable of recording nV-scale signals was designed in accordance with the imposed specifications. Under both in vitro and in vivo experimental conditions, the proposed AFE provided real-time, low-noise and artefact-free LFP recordings (in the frequency range 0.5-250 Hz) during stimulation. Its sensing and stimulation artefact suppression capabilities outperformed the capabilities of the AFE equipped with the Bessel notch filter. Significance. The designed AFE can precisely record LFP signals, in and without the presence of either unipolar or bipolar DBS, which renders it as a functional and practical AFE architecture to be utilised in a wide range of applications and environments. This work paves the way for the development of externalized research tools for closed-loop neuromodulation that use low- and higher-frequency LFPs as control signals.
引用
收藏
页数:22
相关论文
共 60 条
  • [1] Automatic removal of high-amplitude stimulus artefact from neuronal signal recorded in the subthalamic nucleus
    Al-ani, Tarik
    Cazettes, Fanny
    Palfi, Stephane
    Lefaucheur, Jean-Pascal
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2011, 198 (01) : 135 - 146
  • [2] Systems for deep brain stimulation: review of technical features
    Amon, A.
    Alesch, F.
    [J]. JOURNAL OF NEURAL TRANSMISSION, 2017, 124 (09) : 1083 - 1091
  • [3] [Anonymous], 2010, Medical instrumentation: application and design
  • [4] Ardizzoni B J, 2007, HIGH SPEED TIME DOMA, V2, P3
  • [5] Eight-hours adaptive deep brain stimulation in patients with Parkinson disease
    Arlotti, Mattia
    Marceglia, Sara
    Foffani, Guglielmo
    Volkmann, Jens
    Lozano, Andres M.
    Moro, Elena
    Cogiamanian, Filippo
    Prenassi, Marco
    Bocci, Tommaso
    Cortese, Francesca
    Rampini, Paolo
    Barbieri, Sergio
    Priori, Alberto
    [J]. NEUROLOGY, 2018, 90 (11) : E971 - 506
  • [6] An external portable device for adaptive deep brain stimulation (aDBS) clinical research in advanced Parkinson's Disease
    Arlotti, Mattia
    Rossi, Lorenzo
    Rosa, Manuela
    Marceglia, Sara
    Priori, Alberto
    [J]. MEDICAL ENGINEERING & PHYSICS, 2016, 38 (05) : 498 - 505
  • [7] Baker B C, 2015, ANALOG APPL J, P8
  • [8] Basir-Kazeruni S, 2017, I IEEE EMBS C NEUR E, P186, DOI 10.1109/NER.2017.8008322
  • [9] Sixty-Hertz Stimulation Improves Bradykinesia and Amplifies Subthalamic Low-Frequency Oscillations
    Blumenfeld, Zack
    Koop, Mandy Miller
    Prieto, Thomas E.
    Shreve, Lauren A.
    Velisar, Anca
    Quinn, Emma J.
    Trager, Megan H.
    Bronte-Stewart, Helen
    [J]. MOVEMENT DISORDERS, 2017, 32 (01) : 80 - 88
  • [10] Stimulating at the right time: phase-specific deep brain stimulation
    Cagnan, Hayriye
    Pedrosa, David
    Little, Simon
    Pogosyan, Alek
    Cheeran, Binith
    Aziz, Tipu
    Green, Alexander
    Fitzgerald, James
    Foltynie, Thomas
    Limousin, Patricia
    Zrinzo, Ludvic
    Hariz, Marwan
    Friston, Karl J.
    Denison, Timothy
    Brown, Peter
    [J]. BRAIN, 2017, 140 : 132 - 145