Accurate Measurement of Characteristic Response for Unexploded Ordnance With Transient Electromagnetic System

被引:51
|
作者
Chen, Shudong [1 ,2 ]
Zhang, Shuang [1 ]
Zhu, Jun [2 ]
Luan, Xinqun [2 ]
机构
[1] Jilin Univ, Coll Elect Sci & Engn, Changchun 130012, Peoples R China
[2] Sci & Technol Near Surface Detect Lab, Wuxi 214035, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Characteristic response; magnetic polarization tensor (MPT); target classification; transient electromagnetic (TEM); unexploded ordnance (UXO); DISCRIMINATION; IDENTIFICATION; CLASSIFICATION; SENSOR;
D O I
10.1109/TIM.2019.2917236
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Characteristic response parameterized in time-dependent target intrinsic polarizabilities has been widely used to create feature libraries for unexploded ordnance (UXO) discrimination. This paper discusses the accurate measurement of characteristic response for UXOs with transient electromagnetic (TEM) system. First, a specially designed TEM system, which utilizes a modified solenoid and a pair of rectangular coils as transmitting coils to ensure the uniformity of primary field up to 96% throughout the target, is described. Then, the characteristic responses of 12 UXOs are measured from directions vertical or parallel to the axis at distances from 40 to 120 cm. The measured characteristic responses show a power law decay function at an early time and an exponential decay function at a later time. The characteristic responses parallel to the target axis are larger, and the decay is considerably slower than those vertical to the axis, leading to one to two orders of magnitude difference at a later time. Results also show that the characteristic response measured from the direction vertical to the axis of the target is more precise than that from the direction parallel to the axis at the same distance. The portion of the target that is close to the system accounts for a large proportion of the response. A target can be approximated as a single dipole only when it is located no less than twice its length from the system. Finally, the characteristic responses of 12 targets are parameterized with the Pasion-Oldenburg expression for feature library creation.
引用
收藏
页码:1728 / 1736
页数:9
相关论文
共 50 条
  • [41] Measurement of multivalued response curves of a strongly nonlinear system by exploiting exciter dynamics
    Zhang, Genbei
    Zang, Chaoping
    Friswell, Michael, I
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2020, 140 (140)
  • [42] Clinical validation of a precision electromagnetic tremor measurement system in participants receiving deep brain stimulation for essential tremor
    Perera, Thushara
    Yohanandan, Shivanthan A. C.
    Thevathasan, Wesley
    Jones, Mary
    Peppard, Richard
    Evans, Andrew H.
    Tan, Joy L.
    McKay, Colette M.
    McDermott, Hugh J.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (09) : 1516 - 1527
  • [43] A camera-based system for highly accurate 3D displacement field measurement and contactless force sensing
    Zhao, Debbie
    HajiRassouliha, Amir
    Tang, Emily J. Lam Po
    Nash, Martyn P.
    Nielsen, Poul M. F.
    Taberner, Andrew J.
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 752 - 757
  • [44] Accurate Temperature Compensation and Characterization of Overall System Thermal Response Using Total Measured Strain in FBG Sensors
    Haber, T.
    Ferguson, S.
    Guthrie, D.
    Graver, T.
    Soller, B.
    Mendez, A.
    STRUCTURAL HEALTH MONITORING 2013, VOLS 1 AND 2, 2013, : 1326 - +
  • [45] Item response theory-based validation of an integrated management system measurement instrument
    Barbosa, Anrafel de Souza
    da Silva, Luiz Bueno
    Morioka, Sandra Naomi
    Norte da Silva, Jonhatan Magno
    de Souza, Vinicius Fernandes
    JOURNAL OF CLEANER PRODUCTION, 2021, 328
  • [46] Identifying parametric variation in second-order system from frequency response measurement
    Hegde, A.
    Tang, J.
    JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (05) : 879 - 891
  • [47] SIA system employing the transient response from a potentiometric sensor array-Correction of a saline matrix effect
    Mimendia, A.
    Gutierrez, J. M.
    Opalski, L. J.
    Ciosek, P.
    Wroblewski, W.
    del Valle, M.
    TALANTA, 2010, 82 (03) : 931 - 938
  • [48] Multicamera measurement system to evaluate the dynamic response of utility-scale wind turbine blades
    Poozesh, Peyman
    Sabato, Alessandro
    Sarrafi, Aral
    Niezrecki, Christopher
    Avitabile, Peter
    Yarala, Rahul
    WIND ENERGY, 2020, 23 (07) : 1619 - 1639
  • [49] DEVELOPMENT OF ONLINE R-VALUE MEASUREMENT SYSTEM FOR COLD-ROLLED STEEL SHEETS BY USING ELECTROMAGNETIC ACOUSTIC TRANSDUCER
    FUJISAWA, K
    MURAYAMA, R
    YAMAMOTO, F
    TAYA, K
    FUKUOKA, H
    HIRAO, M
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1993, 79 (07): : 869 - 876
  • [50] Frequency response function measurement and parametric SISO system modelling of a gyro-stabilized infrared electro optic gimbal system
    Ozdogan, Gokhan
    Leblebicioglu, Kemal
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2016, 38 (05) : 512 - 528