Accurate Measurement of Characteristic Response for Unexploded Ordnance With Transient Electromagnetic System

被引:51
|
作者
Chen, Shudong [1 ,2 ]
Zhang, Shuang [1 ]
Zhu, Jun [2 ]
Luan, Xinqun [2 ]
机构
[1] Jilin Univ, Coll Elect Sci & Engn, Changchun 130012, Peoples R China
[2] Sci & Technol Near Surface Detect Lab, Wuxi 214035, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Characteristic response; magnetic polarization tensor (MPT); target classification; transient electromagnetic (TEM); unexploded ordnance (UXO); DISCRIMINATION; IDENTIFICATION; CLASSIFICATION; SENSOR;
D O I
10.1109/TIM.2019.2917236
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Characteristic response parameterized in time-dependent target intrinsic polarizabilities has been widely used to create feature libraries for unexploded ordnance (UXO) discrimination. This paper discusses the accurate measurement of characteristic response for UXOs with transient electromagnetic (TEM) system. First, a specially designed TEM system, which utilizes a modified solenoid and a pair of rectangular coils as transmitting coils to ensure the uniformity of primary field up to 96% throughout the target, is described. Then, the characteristic responses of 12 UXOs are measured from directions vertical or parallel to the axis at distances from 40 to 120 cm. The measured characteristic responses show a power law decay function at an early time and an exponential decay function at a later time. The characteristic responses parallel to the target axis are larger, and the decay is considerably slower than those vertical to the axis, leading to one to two orders of magnitude difference at a later time. Results also show that the characteristic response measured from the direction vertical to the axis of the target is more precise than that from the direction parallel to the axis at the same distance. The portion of the target that is close to the system accounts for a large proportion of the response. A target can be approximated as a single dipole only when it is located no less than twice its length from the system. Finally, the characteristic responses of 12 targets are parameterized with the Pasion-Oldenburg expression for feature library creation.
引用
收藏
页码:1728 / 1736
页数:9
相关论文
共 50 条
  • [31] Feature Selection Method for Power System Transient Stability Status Prediction Considering Class Imbalanced Characteristic
    Chen, Zhen
    Han, Xiaoyan
    Zhang, Hua
    Zhao, Juan
    Mei, Shengwei
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [32] A Dual-Function Measurement System for Detection of Very Fast Transient and Partial Discharge
    Wang, Wei
    Zhang, Xiaolong
    Fan, Zhenxing
    Liu, Hao
    Wei, Bin
    Zhou, Shu
    Liao, Xiangdong
    Ma, Guoming
    IEEE SENSORS JOURNAL, 2025, 25 (02) : 3288 - 3294
  • [33] Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system
    Poulin, Eric
    Racine, Emmanuel
    Binnekamp, Dirk
    Beaulieu, Luc
    MEDICAL PHYSICS, 2015, 42 (03) : 1227 - 1232
  • [34] A new method for the accurate measurement of higher-order frequency response functions of nonlinear structural systems
    Lin, R. M.
    Ng, T. Y.
    ISA TRANSACTIONS, 2018, 81 : 270 - 285
  • [35] A Novel ANN-Based Adaptive Ultrasonic Measurement System for Accurate Water Level Monitoring
    Sahoo, Ajit Kumar
    Udgata, Siba Kumar
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 3359 - 3369
  • [36] Measurement-based Cell-DT Method for Power System Transient Stability Classification
    Yang, Yue
    Huang, Yuan
    Liu, Junyong
    Liu, Youbo
    Liu, Tingjian
    Xiang, Yue
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2017, 3 (03): : 278 - 285
  • [37] Measurement-based Power System Dynamic Model for Response Estimation
    Liu, Yong
    Sun, Kai
    Liu, Yilu
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [38] Adaptive response compensation of second-order system in instrumentation (analysis of response characteristics and blind compensation of pressure measurement system)
    Kaifuku K.
    Tagawa M.
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2010, 76 (762): : 239 - 246
  • [39] Reviewing the large electrical network equivalent methods under development for electromagnetic transient studies in the Brazilian Interconnected power system
    Campello, T. M.
    Dicler, F. N. F.
    Varricchio, S. L.
    de Barros, H. M.
    Costa, C. O.
    Lima, A. C. S.
    Taranto, G. N.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 151
  • [40] A rapid response micro-thermocouple used for transient temperature measurement of high-speed gas flow
    Na, Xin
    Xie, Jianbin
    Xu, Lixin
    Wang, Liangbi
    CHINESE SCIENCE BULLETIN-CHINESE, 2019, 64 (31): : 3223 - 3231