Micro-Particle Image Velocimetry Investigation of Flow Fields of SonoVue Microbubbles Mediated by Ultrasound and Their Relationship With Delivery

被引:8
|
作者
Zou, Penglin [1 ]
Li, Mengqi [2 ]
Wang, Ziqi [1 ]
Zhang, Guoxiu [3 ]
Jin, Lifang [1 ]
Pang, Yan [2 ]
Du, Lianfang [1 ]
Duan, Yourong [4 ]
Liu, Zhaomiao [2 ]
Shi, Qiusheng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Dept Ultrasound, Shanghai, Peoples R China
[2] Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing, Peoples R China
[3] Henan Univ Sci & Technol, Affiliated Hosp 1, Dept Emergency, Luoyang, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Med, Shanghai Canc Inst, State Key Lab Oncogenes & Related Genes, Shanghai, Peoples R China
来源
FRONTIERS IN PHARMACOLOGY | 2020年 / 10卷
基金
中国国家自然科学基金;
关键词
flow field; microbubble; delivery; ultrasound; shear stress; INERTIAL CAVITATION; ACOUSTIC PARAMETERS; CONTRAST AGENTS; SONOPORATION; NANOPARTICLES; SINGLE; GEMCITABINE; MECHANISMS; DYNAMICS; EXPOSURE;
D O I
10.3389/fphar.2019.01651
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The flow fields generated by the acoustic behavior of microbubbles can significantly increase cell permeability. This facilitates the cellular uptake of external molecules in a process known as ultrasound-mediated drug delivery. To promote its clinical translation, this study investigated the relationships among the ultrasound parameters, acoustic behavior of microbubbles, flow fields, and delivery results. SonoVue microbubbles were activated by 1 MHz pulsed ultrasound with 100 Hz pulse repetition frequency, 1:5 duty cycle, and 0.20/0.35/0.70 MPa peak rarefactional pressure. Micro-particle image velocimetry was used to detect the microbubble behavior and the resulting flow fields. Then HeLa human cervical cancer cells were treated with the same conditions for 2, 4, 10, 30, and 60 s, respectively. Fluorescein isothiocyanate and propidium iodide were used to quantitate the rates of sonoporated cells with a flow cytometer. The results indicate that (1) microbubbles exhibited different behavior in ultrasound fields of different peak rarefactional pressures. At peak rarefactional pressures of 0.20 and 0.35 MPa, the dispersed microbubbles clumped together into clusters, and the clusters showed no apparent movement. At a peak rarefactional pressure of 0.70 MPa, the microbubbles were partially broken, and the remainders underwent clustering and coalescence to form bubble clusters that exhibited translational oscillation. (2) The flow fields were unsteady before the unification of the microbubbles. After that, the flow fields showed a clear pattern. (3)The delivery efficiency improved with the shear stress of the flow fields increased. Before the formation of the microbubble/bubble cluster, the maximum shear stresses of the 0.20, 0.35, and 0.70 MPa groups were 56.0, 87.5 and 406.4 mPa, respectively, and the rates of the reversibly sonoporated cells were 2.4% +/- 0.4%, 5.5% +/- 1.3%, and 16.6% +/- 0.2%. After the cluster formation, the maximum shear stresses of the three groups were 9.1, 8.7, and 71.7 mPa, respectively. The former two could not mediate sonoporation, whereas the last one could. These findings demonstrate the critical role of flow fields in ultrasound-mediated drug delivery and contribute to its clinical applications.
引用
收藏
页数:13
相关论文
共 19 条
  • [1] Ultrasound mediated destruction of multifunctional microbubbles for image guided delivery of oxygen and drugs
    Chang, Shufang
    Si, Ting
    Zhang, Shiwu
    Merrick, Mark A.
    Cohn, David E.
    Xu, Ronald X.
    ULTRASONICS SONOCHEMISTRY, 2016, 28 : 31 - 38
  • [2] Flow Measurements in a Blood-Perfused Collagen Vessel Using X-Ray Micro-Particle Image Velocimetry
    Antoine, Elizabeth
    Buchanan, Cara
    Fezzaa, Kamel
    Lee, Wah-Keat
    Rylander, M. Nichole
    Vlachos, Pavlos
    PLOS ONE, 2013, 8 (11):
  • [3] Ultrasound wave propagation in tissue and scattering from microbubbles for echo particle image velocimetry technique
    Mukdadi, O
    Shandas, R
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 364 - 370
  • [4] Instantaneous 4D micro-particle image velocimetry (μPIV) via multifocal microscopy (MUM)
    Guastamacchia, M. G. R.
    Xue, R.
    Madi, K.
    Pitkeathly, W. T. E.
    Lee, P. D.
    Webb, S. E. D.
    Cartmell, S. H.
    Dalgarno, P. A.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Particle Image Velocimetry Investigation of the Coherent Structures in a Leading-Edge Slat Flow
    Richard, Patrick R.
    Wilkins, Stephen John
    Hall, Joseph W.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (04):
  • [6] Flow field investigation of high solid anaerobic digestion by Particle Image Velocimetry (PIV)
    Hu, Yuying
    Wu, Jing
    Poncin, Souhila
    Cao, Zhiping
    Li, Zhonghua
    Li, Huai Z.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 626 : 592 - 602
  • [7] A tomographic particle image velocimetry investigation of the flow development over dual step cylinders
    Morton, C.
    Yarusevych, S.
    Scarano, F.
    PHYSICS OF FLUIDS, 2016, 28 (02) : 025104
  • [8] Flow characteristics in free impinging jet reactor by particle image velocimetry (PIV) investigation
    Zhang, Jun
    Liu, Youzhi
    Qi, Guisheng
    Jiao, Weizhou
    Yuan, Zhiguo
    FLUID DYNAMICS RESEARCH, 2016, 48 (04)
  • [9] Particle Image Velocimetry (PIV) Investigation of Blade and Purge Flow Impacts on Inter-Stage Flow Field in a Research Turbine
    Zhang, Zhenyang
    Ma, Hongwei
    ENERGIES, 2019, 12 (07)
  • [10] Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
    Buchmann, N. A.
    Atkinson, C.
    Jeremy, M. C.
    Soria, J.
    EXPERIMENTS IN FLUIDS, 2011, 50 (04) : 1131 - 1151