Critical evaluation of mass spectrometric measurement of dissociation constants: accuracy and cross-validation against surface plasmon resonance and circular dichroism for the calmodulin-melittin system

被引:42
作者
Mathur, Sonal
Badertscher, Martin
Scott, Michael
Zenobi, Renato
机构
[1] ETH, UNI, Funct Genome Ctr, CH-8057 Zurich, Switzerland
[2] ETH, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
关键词
D O I
10.1039/b707946j
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We present a comprehensive study for determining the binding a. ffnity of a protein - ligand complex, using mass spectrometric methods. Mass spectrometry has been used to study noncovalent interactions for a number of years. However, the use of soft ionization mass spectrometry for quantitative analysis of noncovalently bound complexes is not widely accepted. This paper reports a comparison of MS methods against established methods such as surface plasmon resonance (SPR) and circular dichroism (CD) whose suitability for the quantitative assessment of noncovalent interactions is well known. ESI titration and MALDI- SUPREX were used as representative mass spectrometric methods for this work. We chose to study the calmodulin - melittin complex that presents three challenges: ( i) it exhibits a high affinity ( low nanomolar K-D); ( ii) complexes are formed only in the presence of a coactivator, calcium ions in this case; and ( iii) the protein and the complex show a different ionization efficiency. Dissociation constants were obtained from each method for the selected system and compared thoroughly to elucidate pros and cons of the selected methodologies in terms of their ability for the determination of binding constants of protein - ligand complexes. ESI titration, SPR, CD and MALDI- SUPREX yielded KD values in the low nanomolar range that are in general agreement with an older value reported in the literature. We also critically evaluated the limitations in particular of the MS methods and the associated data evaluation procedures. We present an improved evaluation of SUPREX data, as well as a detailed error analysis for all methods used.
引用
收藏
页码:6187 / 6198
页数:12
相关论文
共 53 条
[1]  
Ayed A, 1998, RAPID COMMUN MASS SP, V12, P339, DOI 10.1002/(SICI)1097-0231(19980415)12:7<339::AID-RCM163>3.0.CO
[2]  
2-6
[3]   STRUCTURE OF CALMODULIN REFINED AT 2.2 A RESOLUTION [J].
BABU, YS ;
BUGG, CE ;
COOK, WJ .
JOURNAL OF MOLECULAR BIOLOGY, 1988, 204 (01) :191-204
[4]   OBSERVATION OF LARGE MULTIMERS IN THE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF PEPTIDES [J].
BUSMAN, M ;
KNAPP, DR ;
SCHEY, KL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (02) :211-216
[5]   CA2+-DEPENDENT HIGH-AFFINITY COMPLEX-FORMATION BETWEEN CALMODULIN AND MELITTIN [J].
COMTE, M ;
MAULET, Y ;
COX, JA .
BIOCHEMICAL JOURNAL, 1983, 209 (01) :269-272
[6]   INTERACTIVE PROPERTIES OF CALMODULIN [J].
COX, JA .
BIOCHEMICAL JOURNAL, 1988, 249 (03) :621-629
[7]  
COX JA, 1985, J BIOL CHEM, V260, P2527
[8]   FALSE POSITIVES AND THE DETECTION OF CYCLODEXTRIN INCLUSION COMPLEXES BY ELECTROSPRAY MASS-SPECTROMETRY [J].
CUNNIFF, JB ;
VOUROS, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (05) :437-447
[9]   Quantitative determination of noncovalent binding interactions using soft ionization mass spectrometry [J].
Daniel, JM ;
Friess, SD ;
Rajagopalan, S ;
Wendt, S ;
Zenobi, R .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 216 (01) :1-27
[10]   A deconvolution method for the separation of specific versus nonspecific interactions in noncovalent protein-ligand complexes analyzed by ESI-FT-ICR mass spectrometry [J].
Daubenfeld, Thorsten ;
Bouin, Anne-Pascale ;
van der Rest, Guillaume .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (09) :1239-1248