Compensation control and parameters design for high frequency resonance suppression of MMC-HVDC system

被引:30
作者
Li, Yunfeng [1 ]
Pang, Hui [2 ,3 ]
Kong, Ming [2 ,3 ]
Lu, Jingjing [2 ,3 ]
Ji, Ke [2 ,3 ]
Tang, Guangfu [2 ,3 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha 410114, Peoples R China
[2] Global Energy Interconnect Res Inst, Beijing 102209, Peoples R China
[3] State Key Lab Adv Transmiss Technol, Beijing 102209, Peoples R China
基金
中国国家自然科学基金;
关键词
Compensation control; high frequency resonance; high voltage direct current; impedance model; modular multilevel converter; parameter design; time delay; MODULAR MULTILEVEL CONVERTER; VSC-HVDC; DQ; INVERTER; SEQUENCE; STRATEGY; IMPROVE; MODEL;
D O I
10.17775/CSEEJPES.2020.03860
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Large time delay is one of the inherent features of a modular multilevel converter (MMC)-based high voltage direct current (HVDC) system and is the main factor leading to the unfavorable 'negative resistance and inductance' characteristic of MMC impedance. Research indicates that this characteristic interacting with the capacitive characteristics of an AC system is the cause of high frequency resonance (HFR) in the Yu-E HVDC project. As the current controller is one of the main factors that affects the MMC impedance, a compensation control to imitate the paralleled impedance at the point of common coupling (PCC) is proposed. Therefore, the structure and parameter design of the compensation controller are core to realizing HFR suppression. There are two potentially risky frequency ranges of HFRs (around 700 Hz and 1.8 kHz) in the studied AC system within 2.0 kHz. The core concept of HFR suppression is to make the phase angle of MMC impedance smaller than 90 degrees in the two risky frequency ranges according to impedance stability theory. Hence, the design parameters aim to coordinate the phase angle of MMC impedance in the two risky frequency ranges. In this paper, three types of compensation controller are studied to suppress HFRs, namely, first-order low pass filter (LPF), second-order LPF, and third-order band pass filter. The results of parameter design show that the first-order LPF cannot suppress both HFRs simultaneously. The second-order LPF can suppress both HFRs, however, it introduces a DC component into the current control loop. Therefore, a high pass filter is added to form the recommended third-order controller. All parameter ranges of the compensation controller are derived using analytical expressions. Finally, the correctness of the parameter design is proofed using time-domain simulations.
引用
收藏
页码:1161 / 1175
页数:15
相关论文
共 34 条
[1]  
[Anonymous], 2018, Relationships Education, Relationships and Sex Education (RSE) and Health Education, P1
[2]   Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1254-1261
[3]   Overview of Mechanism and Mitigation Measures on Multi-frequency Oscillation Caused by Large-scale Integration of Wind Power [J].
Chi, Yongning ;
Tang, Bingjie ;
Hu, Jiabing ;
Tian, Xinshou ;
Tang, Haiyan ;
Li, Yan ;
Sun, Sujuan ;
Shi, Lei ;
Shuai, Lei .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2019, 5 (04) :433-443
[4]   Circulating Current Suppression for MMC-HVDC Systems with Asymmetric Arm Impedance [J].
Deng, Fujin ;
Heng, Qian ;
Liu, Chengkai ;
Lyu, Yongqing ;
Wang, Qingsong ;
Liu, Dan ;
Zhu, Rongwu .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2021, 7 (03) :530-540
[5]   Pade-Based Stability Analysis for a Modular Multilevel Converter Considering the Time Delay in the Digital Control System [J].
Dong, Chaoyu ;
Yang, Shunfeng ;
Jia, Hongjie ;
Wang, Peng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (07) :5242-5253
[6]   Pre-charging strategy with damping control of isolated station connected to the modular multilevel converter based DC grid [J].
Guo, Xianshan ;
Li, Yunfeng ;
Mei, Nian ;
He, Zhiyuan ;
Pang, Hui .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (02) :316-326
[7]   Reduced-Order Small-Signal Models of Modular Multilevel Converter and MMC-Based HVdc Grid [J].
Hao, Quanrui ;
Li, Zheng ;
Gao, Feng ;
Zhang, Jing .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (03) :2257-2268
[8]   VSC Input-Admittance Modeling and Analysis Above the Nyquist Frequency for Passivity-Based Stability Assessment [J].
Harnefors, Lennart ;
Finger, Raphael ;
Wang, Xiongfei ;
Bai, Haofeng ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (08) :6362-6370
[9]   Damping Low-Frequency Oscillations Through VSC-HVdc Stations Operated as Virtual Synchronous Machines [J].
Huang, Linbin ;
Xin, Huanhai ;
Wang, Zhen .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (06) :5803-5818
[10]   Small-Signal Dynamic DQ Model of Modular Multilevel Converter for System Studies [J].
Jamshidifar, Aliakbar ;
Jovcic, Dragan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (01) :191-199