A microfluidic paper-based analytical device for the assay of albumin-corrected fructosamine values from whole blood samples

被引:8
作者
Boonyasit, Yuwadee [1 ]
Laiwattanapaisal, Wanida [2 ]
机构
[1] Chulalongkorn Univ, Fac Allied Hlth Sci, Grad Program Clin Biochem & Mol Med, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Bangkok 10330, Thailand
关键词
DIABETIC-PATIENTS; GLYCEMIC CONTROL; POINT; IMMUNODEVICE; HEMOGLOBIN; GLUCOSE; URINE;
D O I
10.4155/bio.14.199
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: A method for acquiring albumin-corrected fructosamine values from whole blood using a microfluidic paper-based analytical system that offers substantial improvement over previous methods is proposed. Results: The time required to quantify both serum albumin and fructosamine is shortened to 10 min with detection limits of 0.50 g dl(-1) and 0.58 mM, respectively (S/N = 3). The proposed system also exhibited good within-run and run-to-run reproducibility. The results of the interference study revealed that the acceptable recoveries ranged from 95.1 to 106.2%. The system was compared with currently used large-scale methods (n = 15), and the results demonstrated good agreement among the techniques. Conclusion: The microfluidic paper-based system has the potential to continuously monitor glycemic levels in low resource settings.
引用
收藏
页码:79 / 90
页数:12
相关论文
共 42 条
[1]  
BAKER J, 1991, CLIN CHEM, V37, P552
[2]  
Baker JR., 1987, [No title captured], Patent No. [US4642295, 4642295]
[3]   Determination of nitrite in saliva using microfluidic paper-based analytical devices [J].
Bhakta, Samir A. ;
Borba, Rubiane ;
Taba, Mario, Jr. ;
Garcia, Carlos D. ;
Carrilho, Emanuel .
ANALYTICA CHIMICA ACTA, 2014, 809 :117-122
[4]   MEASUREMENT OF GLYCOSYLATED AMINO-ACIDS AND PEPTIDES FROM URINE OF DIABETIC-PATIENTS USING AFFINITY-CHROMATOGRAPHY [J].
BROWNLEE, M ;
VLASSARA, H ;
CERAMI, A .
DIABETES, 1980, 29 (12) :1044-1047
[5]  
Brun JF, 2004, CLIN HEMORHEOL MICRO, V30, P365
[6]  
Burd JF, 1997, [No title captured], Patent No. [US5639672, 5639672]
[7]  
Burd JF, 1995, [No title captured], Patent No. [US5470752, 5470752]
[8]   Hemoglobin A1c and Fructosamine for Assessing Glycemic Control in Diabetic Patients With CKD Stages 3 and 4 [J].
Chen, Harn-Shen ;
Wu, Tzu-En ;
Lin, Hong-Da ;
Jap, Tjin-Shing ;
Hsiao, Li-Chuan ;
Lee, Shen-Hung ;
Lin, Shu-Hsia .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2010, 55 (05) :867-874
[9]   US Renal Data System 2011 Annual Data Report [J].
Collins, Allan J. ;
Foley, Robert N. ;
Chavers, Blanche ;
Gilbertson, David ;
Herzog, Charles ;
Johansen, Kirsten ;
Kasiske, Bertram ;
Kutner, Nancy ;
Liu, Jiannong ;
St Peter, Wendy ;
Guo, Haifeng ;
Gustafson, Sally ;
Heubner, Brooke ;
Lamb, Kenneth ;
Li, Shuling ;
Li, Suying ;
Peng, Yi ;
Qiu, Yang ;
Roberts, Tricia ;
Skeans, Melissa ;
Snyder, Jon ;
Solid, Craig ;
Thompson, Bryn ;
Wang, Changchun ;
Weinhandl, Eric ;
Zaun, David ;
Arko, Cheryl ;
Chen, Shu-Cheng ;
Daniels, Frank ;
Ebben, James ;
Frazier, Eric ;
Hanzlik, Christopher ;
Johnson, Roger ;
Sheets, Daniel ;
Wang, Xinyue ;
Forrest, Beth ;
Constantini, Edward ;
Everson, Susan ;
Eggers, Paul ;
Agodoa, Lawrence .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2012, 59 (01) :EVII-E418
[10]  
CORONEL F, 1991, ADV PERIT D, V7, P253