NOISE MEASUREMENTS AND REDUCTION FOR HIGH-FREQUENCY VIBRATING DEVICES IN THE APPLICATION OF COOLING ELECTRONICS

被引:0
作者
Huang, Longzhong [1 ]
Simon, Terrence [1 ]
Zhang, Min [1 ]
Yeom, Taiho [1 ]
North, Mark [2 ]
Cui, Tianhong [1 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
[2] Thermacore Inc, Lancaster, PA 17601 USA
来源
PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D | 2013年
关键词
Electronics cooling; Noise reduction; Muffler; Synthetic jet; Agitation; SYNTHETIC JET; HEAT-TRANSFER; EXPANSION CHAMBER; SOUND;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Traditional heat sinks for electronics cooling have become ever more difficult to design to meet the high dissipation rate of modem high-heat-flux electronics. Active devices, especially devices operating at a high frequency, show promise toward enhancing heat transfer performance. However, active devices generate noise that may not be acceptable to personnel. The present work studies acoustic characteristics of piezoelectrically-driven synthetic jets and oscillating plate agitators operating at high frequency (around 1000 Hz) employed in an electronics cooling module for heat transfer enhancement purposes. The A-weighted noise level from such actuators is measured and found to increase with increases of driving voltage and operational frequency. The measured sound pressure level of the active devices used in our present enhanced heat transfer module can be as high as 100 dB. Through a power spectrum analysis, we find that most acoustic energy is in a narrow frequency band close to the operating frequency of the active device. To decrease the noise level, a muffler, which also allows cooling air to recirculate through the equipment cabinet, has been designed and tested. An analytical model is employed to select the geometry of the muffler for optimal performance based on acoustic characteristics of the active devices and the through-flow pressure drop. The muffler having this optimal design is fabricated and tested and found to be able to decrease the noise level generated by two actuators from 83 dB to 64 dB.
引用
收藏
页码:1497 / 1504
页数:8
相关论文
共 31 条
  • [31] Zharig M., 2011, P ASME 2011 INT MECH