Experimental study of bone drilling by Kirschner wire

被引:7
作者
Song, Shaokang [1 ]
Cheng, Xiang [1 ]
Li, Tao [2 ]
Shi, Ming [2 ]
Zheng, Guangming [1 ]
Liu, Huanbao [1 ]
机构
[1] Shandong Univ Technol, Sch Mech Engn, Zibo 255000, Peoples R China
[2] Zibo Cent Hosp, Zibo 255000, Peoples R China
关键词
Kirschner wire; Cortical bone; Drilling temperature; Burr; Force; TEMPERATURE; OPTIMIZATION; PARAMETERS; HEAT;
D O I
10.1016/j.medengphy.2022.103835
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mechanical and thermal damage to the bone tissue during drilling process is inevitable and directly affects the postoperative recovery. According to clinical practices and present academic investigations, this study tries to reduce bone damage by experimental investigation of bone drilling by Kirschner wire considering the drilling force and temperature factors. Finite element method has been applied to modelling of the drilling process. Then, grouped experiments have been carried out using bovine femoral bone and analyzed based on the orthogonal experimental method. The influence of key parameters such as Kirschner wire bevel angle, feed speed and rotational speed on the microscopic bone chip size, drilling force, drilling temperature and hole inlet burr was analyzed to conduct comprehensive analysis and optimizations. It is certain that the chips size is closely related to drilling force and drilling temperature. The low drilling temperature does not mean that the damage area is small. The drilling process should be completed quickly at high feed rates. The lower rotational speed, Kirschner wire bevel angle, and higher feed rate help reduce the thermal damage area of the bone drill, effectively reduce the drilling force and hole entrance burrs.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Kirschner Wire and Bone Cement is a Viable Alternative to Reconstruction of Large Iliac Bone Defects After Strut Bone Graft Harvesting [J].
Yu, Shang-Won ;
Wu, Chin-Hsien ;
Yeh, James Jih-Hsi ;
Yen, Cheng-Yo ;
Ma, Ching-Hou ;
Tu, Yuan-Kun .
CLINICAL SPINE SURGERY, 2017, 30 (07) :308-313
[42]   Experimental investigation of the temperature during bone drilling using thermocouples and numerical finite element analysis [J].
Vilimek, Miloslav ;
Horak, Zdenek ;
Goldmann, Tomas ;
Tichy, Petr ;
Ihde, Stefan .
BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2021, 35 (01) :1263-1273
[43]   One century of Kirschner wires and Kirschner wire insertion techniques : A historical review [J].
Franssen, Bas B. G. M. ;
Schuurman, Arnold H. ;
Van der Molen, Aebele Mink ;
Kon, Moshe .
ACTA ORTHOPAEDICA BELGICA, 2010, 76 (01) :1-6
[44]   Drilling Force and Temperature of Bone under Dry and Physiological Drilling Conditions [J].
Xu Linlin ;
Wang Chengyong ;
Jiang Min ;
He Huiyu ;
Song Yuexian ;
Chen Hanyuan ;
Shen Jingnan ;
Zhang Jiayong .
CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2014, 27 (06) :1240-1248
[45]   In vitro comparison of conventional surgical and rotary ultrasonic bone drilling techniques [J].
Gupta, Vishal ;
Singh, Ravinder Pal ;
Pandey, Pulak M. ;
Gupta, Ravi .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (04) :398-411
[46]   A Thermal and Biological Analysis of Bone Drilling [J].
Aghvami, Maziar ;
Brunski, John B. ;
Tulu, U. Serdar ;
Chen, Chih-Hao ;
Helms, Jill A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (10)
[47]   Effects of various drilling parameters on bone during implantology: An in vitro experimental study [J].
Karaca, Faruk ;
Aksakal, Bunyamin .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2013, 15 (04) :25-32
[48]   Pericardial tamponade caused by a migratory Kirschner wire [J].
Lin, Feng ;
Pu, Qiang ;
Ma, Lin ;
Liu, Lunxu .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (03) :1012-1012
[49]   Intra-abdominal migration of a Kirschner wire [J].
Hrvoje Štalekar ;
Karmen Lončarek ;
Miljenko Kovačević .
Wiener klinische Wochenschrift, 2010, 122 :140-140
[50]   Experimental analysis of drilling process in cortical bone [J].
Wang, Wendong ;
Shi, Yikai ;
Yang, Ning ;
Yuan, Xiaoqing .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (02) :261-266