摘要
The development of portable systems for analysis of nucleic acids (NAs) is crucial for the evolution of biosensing in the context of future healthcare technologies. The integration of NA extraction, purification, and detection modules, properly actuated by microfluidics technologies, is a key point for the development of portable diagnostic systems. In this paper, we describe an integrated biosensor platform based on a silicon-plastic hybrid lab-on-disk technology capable of managing NA extraction, purification, and detection processes in an integrated format. The sample preparation process is performed by solid-phase extraction technology using magnetic beads on a plastic disk, while detection is done through quantitative real-time polymerase chain reaction (qRT-PCR) on a miniaturized silicon device. The movement of sample and reagents is actuated by a centrifugal force induced by a disk actuator instrument. The assessment of the NA extraction and detection performance has been carried out by using hepatitis B virus (HBV) DNA genome as a biological target. The quantification of the qRT-PCR chip in the hybrid disk showed an improvement in sensitivity with respect to the qRT-PCR commercial platforms, which means an optimization of time and cost. Limit of detection and limit of quantification values of about 8 cps/reaction and 26 cps/reaction, respectively, were found by using analytical samples (synthetic clone), while the results with real samples (serum with spiked HBV genome) indicate that the system performs as well as the standard methods.
引用
收藏
页码:1554 / 1561
页数:8
相关论文
共 50 条
  • [1] PMMA biosensor for nucleic acids with integrated mixer and electrochemical detection
    Nugen, Sam R.
    Asiello, Peter J.
    Connelly, John T.
    Baeumner, Antje J.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2428 - 2433
  • [2] An integrated platform for rotavirus nucleic acid detection
    Gao, E-Bin
    Lu, Wenxi
    Hu, Yurun
    Xu, Qinggang
    Ni, Zhong
    Wu, Junhua
    Huang, Guoping
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 435
  • [3] Portable surface plasmon resonance biosensor for detection of nucleic acids
    Sipova, H.
    Piliarik, M.
    Vala, M.
    Chadt, K.
    Adam, P.
    Bockova, M.
    Hegnerova, K.
    Homola, J.
    EUROSENSORS XXV, 2011, 25
  • [4] A new biosensor based on PVDF film for detection of nucleic acids
    Zhao, Bei
    Hu, Jie
    Ren, Wei
    Xu, Feng
    Wu, Xiaoqing
    Shi, Peng
    Ye, Zuo-Guang
    CERAMICS INTERNATIONAL, 2015, 41 : S602 - S606
  • [5] Progress on Detection of Metals Ions by Functional Nucleic Acids Biosensor
    Du Zai-Hui
    Li Xiang-Yang
    Tian Jing-Jing
    Zhang Yang-Zi
    Tian Hong-Tao
    Xu Wen-Tao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (07) : 995 - 1004
  • [6] Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat
    Kwakye, Sylvia
    Goral, Vasily N.
    Baeumner, Antje J.
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (12): : 2217 - 2223
  • [7] Integrated optic interferometer for the direct detection of nucleic acids
    Schneider, BH
    Shafer, DA
    Hartman, NF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 93 - ANYL
  • [8] A lateral flow biosensor for detection of nucleic acids with high sensitivity and selectivity
    Lie, Puchang
    Liu, Jie
    Fang, Zhiyuan
    Dun, Boying
    Zeng, Lingwen
    CHEMICAL COMMUNICATIONS, 2012, 48 (02) : 236 - 238
  • [9] Integrated optic interferometer for the direct detection of nucleic acids
    Schneider, BH
    Shafer, DA
    Hartman, NF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 54 - BTEC
  • [10] An integrated impedance biosensor platform for detection of pathogens in poultry products
    Jiayu Liu
    Ibrahem Jasim
    Amjed Abdullah
    Zhenyu Shen
    Lu Zhao
    Majed El-Dweik
    Shuping Zhang
    Mahmoud Almasri
    Scientific Reports, 8