Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile

被引:45
作者
Yang, Chuang-bo [1 ]
Zhang, Shuang [2 ]
Jia, Yong-jun [1 ]
Duan, Hai-feng [1 ]
Ma, Guang-ming [1 ]
Zhang, Xi-rong [1 ]
Yu, Yong [1 ]
He, Tai-ping [1 ]
机构
[1] Shaanxi Univ Chinese Med, Affiliated Hosp, Dept Diagnost Radiol, Weiyang Western Rd 2, Xianyang 712000, Peoples R China
[2] Shaanxi Inst Int Trade & Commerce, Sch Med, Dept Basic Chem, Xian 712046, Shaanxi, Peoples R China
关键词
Tomography; X-ray computed; dual-energy CT; material decomposition; cholesterol gallstones; IN-VITRO; CT; CHOLEDOCHOLITHIASIS; EXPERIENCE; VIVO;
D O I
10.1016/j.acra.2016.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. Materials and Methods: This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Results: Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 +/- 262.36 mg/mL), CT number at 40 keV (-31.57 +/- 16.88 HU) and 140 keV (24.30 +/- 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 +/- 105.12 mg/mL; 12.99 +/- 9.39 HU and 6.19 +/- 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0:994 for differentiating cholesterol gallstones tom bile. Conclusions: Virtual monochromatic. spectral CT images at 40 keV and 140 keV provide significant CT number differences between, cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
[41]   Dual-Energy Computed Tomography Image Acquisition, Processing, and Workflow [J].
Megibow, Alec J. ;
Kambadakone, Avinash ;
Ananthakrishnan, Lakshmi .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) :507-+
[42]   Strategies to Improve Image Quality on Dual-Energy Computed Tomography [J].
Patel, Bhavik N. ;
Marin, Daniele .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) :641-+
[43]   Deep learning based spectral extrapolation for dual-source, dual-energy x-ray computed tomography [J].
Clark, Darin P. ;
Schwartz, Fides R. ;
Marin, Daniele ;
Ramirez-Giraldo, Juan C. ;
Badea, Cristian T. .
MEDICAL PHYSICS, 2020, 47 (09) :4150-4163
[44]   New Applications of Cardiac Computed Tomography Dual-Energy, Spectral, and Molecular CT Imaging [J].
Danad, Ibrahim ;
Fayad, Zahi A. ;
Willemink, Martin J. ;
Min, James K. .
JACC-CARDIOVASCULAR IMAGING, 2015, 8 (06) :710-723
[45]   Spectral Properties of Abdominal Tissues on Dual-energy Computed Tomography and the Effects of Contrast Agent [J].
Kreul, Diana A. ;
Kubik-Huch, Rahel A. ;
Froehlich, John ;
Thali, Michael J. ;
Niemann, Tilo .
IN VIVO, 2021, 35 (06) :3277-3287
[46]   The evolution and current situation in the application of dual-energy computed tomography: a bibliometric study [J].
Wang, Ya ;
Peng, Yun ;
Wang, Tongtong ;
Li, Hui ;
Zhao, Zhen ;
Gong, Lianggeng ;
Peng, Bibo .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) :6801-6813
[47]   Determination of Renal Stone Composition with Dual-Energy Computed Tomography: An Emerging Application [J].
Eliahou, Ruth ;
Hidas, Guy ;
Duvdevani, Mordechai ;
Sosna, Jacob .
SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (04) :315-320
[48]   Questionnaire Survey of Dual-energy Computed Tomography Utilization in Clinical Practice in Japan [J].
Ohira, Shingo ;
Mochizuki, Junji ;
Itaya, Shunsuke ;
Kojima, Tsukasa ;
Hoyoshi, Kazutaka ;
Endo, Kazuyuki ;
Kitera, Nobuo ;
Sakabe, Daisuke ;
Minamitani, Masanari ;
Katano, Atsuto ;
Nakagawa, Keiichi .
IN VIVO, 2025, 39 (04) :2377-2386
[49]   Dual-energy computed tomography: Tube current settings and detection of uric acid tophi [J].
Kotlyarov, Maximilian ;
Hermann, Kay Geert A. ;
Mews, Jurgen ;
Hamm, Bernd ;
Diekhoff, Torsten .
EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139
[50]   Usefulness of advanced monoenergetic reconstruction technique in dual-energy computed tomography for detecting bladder cancer [J].
Motoo Nakagawa ;
Taku Naiki ;
Aya Naiki-Ito ;
Yoshiyuki Ozawa ;
Masashi Shimohira ;
Masahiro Ohnishi ;
Yuta Shibamoto .
Japanese Journal of Radiology, 2022, 40 :177-183