Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile

被引:45
作者
Yang, Chuang-bo [1 ]
Zhang, Shuang [2 ]
Jia, Yong-jun [1 ]
Duan, Hai-feng [1 ]
Ma, Guang-ming [1 ]
Zhang, Xi-rong [1 ]
Yu, Yong [1 ]
He, Tai-ping [1 ]
机构
[1] Shaanxi Univ Chinese Med, Affiliated Hosp, Dept Diagnost Radiol, Weiyang Western Rd 2, Xianyang 712000, Peoples R China
[2] Shaanxi Inst Int Trade & Commerce, Sch Med, Dept Basic Chem, Xian 712046, Shaanxi, Peoples R China
关键词
Tomography; X-ray computed; dual-energy CT; material decomposition; cholesterol gallstones; IN-VITRO; CT; CHOLEDOCHOLITHIASIS; EXPERIENCE; VIVO;
D O I
10.1016/j.acra.2016.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. Materials and Methods: This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Results: Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 +/- 262.36 mg/mL), CT number at 40 keV (-31.57 +/- 16.88 HU) and 140 keV (24.30 +/- 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 +/- 105.12 mg/mL; 12.99 +/- 9.39 HU and 6.19 +/- 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0:994 for differentiating cholesterol gallstones tom bile. Conclusions: Virtual monochromatic. spectral CT images at 40 keV and 140 keV provide significant CT number differences between, cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
[21]   Dual-Energy Computed Tomography for Stone Type Assessment: A Pilot Study of Dual-Energy Computed Tomography with Five Indices [J].
Rudenko, Vadim ;
Serova, Natalia ;
Kapanadze, Lida ;
Taratkin, Mark ;
Okhunov, Zhamshid ;
Leonard, Stephen P. ;
Ritter, Manuel ;
Kriegmair, Maximilian ;
Snurnitsyna, Olesya ;
Kozlov, Vasiliy ;
Laukhtina, Ekaterina ;
Arshiev, Magomed ;
Aleksandrova, Ksenia ;
Salomon, Georg ;
Enikeev, Dmitry ;
Glybochko, Petr .
JOURNAL OF ENDOUROLOGY, 2020, 34 (09) :893-899
[22]   Image Enhancement by Spectral-Error Correction for Dual-Energy Computed Tomography [J].
Park, Kyung-Kook ;
Oh, Chang-Hyun ;
Akay, Metin .
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, :8491-8494
[23]   Dual-Energy, Spectral and Photon Counting Computed Tomography for Evaluation of the Gastrointestinal Tract [J].
Nehra, Avinash K. ;
Dane, Bari ;
Yeh, Benjamin M. ;
Fletcher, Joel G. ;
Leng, Shuai ;
Mileto, Achille .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) :1031-1049
[24]   The application of dual-energy computed tomography in the diagnosis of acute gouty arthritis [J].
Wu, Huaxiang ;
Xue, Jing ;
Ye, Lu ;
Zhou, Qijing ;
Shi, Dan ;
Xu, Rongzhen .
CLINICAL RHEUMATOLOGY, 2014, 33 (07) :975-979
[25]   Dual-Energy Computed Tomography: Integration Into Clinical Practice and Cost Considerations [J].
Ananthakrishnan, Lakshmi ;
Kulkarni, Naveen ;
Toshav, Aran .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) :963-971
[26]   Dual-Energy Computed Tomography of the Liver: Uses in Clinical Practices and Applications [J].
Tsurusaki, Masakatsu ;
Sofue, Keitaro ;
Hori, Masatoshi ;
Sasaki, Kosuke ;
Ishii, Kazunari ;
Murakami, Takamichi ;
Kudo, Masatoshi .
DIAGNOSTICS, 2021, 11 (02)
[27]   Clinical Applications of Dual-Energy Computed Tomography for Acute Ischemic Stroke [J].
Chen, Huanwen ;
Bodanapally, Uttam K. ;
Colasurdo, Marco ;
Malhotra, Ajay ;
Gandhi, Dheeraj .
STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2024, 4 (02)
[28]   Development of Cu application using dual-energy computed tomography for detecting medication-related osteonecrosis of the jaw [J].
Kazuki Shigenaga ;
Satomi Arimoto ;
Masahiro Kubo ;
Takumi Sato ;
Yujiro Hiraoka ;
Daisuke Takeda ;
Takumi Hasegawa ;
Kiyosumi Kagawa ;
Masaya Akashi .
Journal of Bone and Mineral Metabolism, 2023, 41 :865-876
[29]   Dual-energy computed tomography diagnostics for gout [J].
Rech, H. J. ;
Cavallaro, A. .
ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (07) :580-588
[30]   Imaging of nanoparticles with dual-energy computed tomography [J].
Ducote, J. L. ;
Alivov, Y. ;
Molloi, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07) :2031-2044