A preliminary evaluation work on a 3-D ultrasound imaging system for 2-D array transducer

被引:0
|
作者
Zhong, Xiaoli [1 ]
Li, Xu [1 ]
Yang, Jiali [1 ]
Li, Chunyu [1 ]
Song, Junjie [1 ]
Ding, Mingyue [1 ]
Ming Yuchi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Key Lab Image Proc & Intelligence Control, Sch Life Sci & Technol, Dept Biomed Engn,Minist Educ, Wuhan 430074, Hubei, Peoples R China
来源
MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY | 2016年 / 9790卷
关键词
3-D ultrasound imaging system; 2-D array transducer; performance evaluation; DESIGN;
D O I
10.1117/12.2216232
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents a preliminary evaluation work on a pre-designed 3-D ultrasound imaging system. The system mainly consists of four parts, a 7.5MHz, 24x24 2-D array transducer, the transmit/receive circuit, power supply, data acquisition and real-time imaging module. The row-column addressing scheme is adopted for the transducer fabrication, which greatly reduces the number of active channels. The element area of the transduceris 4.6mm by 4.6mm, Four kinds of tests were carried out to evaluate the imaging performance, including the penetration depth range, axial and lateral resolution, positioning accuracy and 3-D imaging frame rate. Several strong reflection metal objects, fixed in a water tank, were selected for the purpose of imaging due to a low signal-to-noise ratio of the transducer. The distance between the transducer and the tested objects, the thickness of aluminum, and the seam width of the aluminum sheet were measured by a calibrated micrometer to evaluate the penetration depth, the axial and lateral resolution, respectively. The experimental results showed that the imaging penetration depth range was from 1.0cm to 6.2cm, the axial and lateral resolution were 0.32mm and 1.37mm respectively, the imaging speed was up to 27 frames per second and the positioning accuracy was 9.2%.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Requirements and Hardware Limitations of High-Frame-Rate 3-D Ultrasound Imaging Systems
    Giangrossi, Claudio
    Ramalli, Alessandro
    Dallai, Alessandro
    Mazierli, Daniele
    Meacci, Valentino
    Boni, Enrico
    Tortoli, Piero
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [42] Architectural analysis of 1-D to 2-D array conversion of priority encoder
    Mishra, Alok Kumar
    Anand, Shail
    Singh, Nishant
    Dhandapani, Vaithiyanathan
    Kaur, Baljit
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2023, 14 (05) : 1726 - 1737
  • [43] Optimal virtual sources distribution in 3-D Diverging Wave Ultrasound Imaging: an experimental study
    Mattesini, Paolo
    Le Moign, Goulven
    Roux, Emmanuel
    Badescu, Emilia
    Petrusca, Lorena
    Basset, Olivier
    Tortoli, Piero
    Liebgott, Herve
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [44] The deployment of 3-D morphing surfaces: A 2-D auxetic metamaterial approach through buckling-induced mechanism
    Lu, Chengyang
    Li, Ruizhi
    Zheng, Yifan
    Pan, Fei
    Chen, Yuli
    Zhang, Xiaotian
    COMPOSITE STRUCTURES, 2024, 348
  • [45] Fast and Accurate Investigation of 2-D Multilayered Photonic Crystals by a 3-D Model Based on the Green's Function
    Ciminelli, Caterina
    Marani, Roberto
    Armenise, Mario Nicola
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2010, 46 (11) : 1549 - 1560
  • [46] Distinct 2-D and 3-D Co(II) coordination polymers with 5-bromonicotinate induced by different synthetic approaches
    Chen, Jing
    Liu, Peng-Wen
    Li, Cheng-Peng
    INORGANIC CHEMISTRY COMMUNICATIONS, 2013, 36 : 105 - 108
  • [47] 3-D glass integrated stacked patch antenna array for silicon active package system
    Yang, Lei
    Wang, Kan
    Wang, Binbin
    Wang, Yang
    IET MICROWAVES ANTENNAS & PROPAGATION, 2024, 18 (04) : 239 - 247
  • [48] Bandpass Absorptive Frequency-Selective Structures With Wide Absorption Bands Based on Hybrid 2-D and 3-D Structures
    Yu, Weiliang
    Cheng, Mengmeng
    Yu, Yufeng
    Wang, Wenlei
    Liu, Leilei
    Luo, Guo Qing
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2023, 71 (04) : 3183 - 3192
  • [49] Performance evaluation of a 3D imaging system for vehicle safety
    Lytle, Alan M.
    Szabo, Sandor
    Cheok, Gerry
    Saidi, Kamel
    Norcross, Rick
    UNMANNED SYSTEMS TECHNOLOGY IX, 2007, 6561
  • [50] Dual Imager Core Chip with 24.8 Rangemaps/s 3-D and 58 fps 2-D Simultaneous Capture Capability
    Mandai, Shingo
    Nakura, Toru
    Ikeda, Makoto
    Asada, Kunihiro
    IEICE TRANSACTIONS ON ELECTRONICS, 2009, E92C (06): : 798 - 805