A preliminary evaluation work on a 3-D ultrasound imaging system for 2-D array transducer

被引:0
|
作者
Zhong, Xiaoli [1 ]
Li, Xu [1 ]
Yang, Jiali [1 ]
Li, Chunyu [1 ]
Song, Junjie [1 ]
Ding, Mingyue [1 ]
Ming Yuchi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Key Lab Image Proc & Intelligence Control, Sch Life Sci & Technol, Dept Biomed Engn,Minist Educ, Wuhan 430074, Hubei, Peoples R China
来源
MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY | 2016年 / 9790卷
关键词
3-D ultrasound imaging system; 2-D array transducer; performance evaluation; DESIGN;
D O I
10.1117/12.2216232
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents a preliminary evaluation work on a pre-designed 3-D ultrasound imaging system. The system mainly consists of four parts, a 7.5MHz, 24x24 2-D array transducer, the transmit/receive circuit, power supply, data acquisition and real-time imaging module. The row-column addressing scheme is adopted for the transducer fabrication, which greatly reduces the number of active channels. The element area of the transduceris 4.6mm by 4.6mm, Four kinds of tests were carried out to evaluate the imaging performance, including the penetration depth range, axial and lateral resolution, positioning accuracy and 3-D imaging frame rate. Several strong reflection metal objects, fixed in a water tank, were selected for the purpose of imaging due to a low signal-to-noise ratio of the transducer. The distance between the transducer and the tested objects, the thickness of aluminum, and the seam width of the aluminum sheet were measured by a calibrated micrometer to evaluate the penetration depth, the axial and lateral resolution, respectively. The experimental results showed that the imaging penetration depth range was from 1.0cm to 6.2cm, the axial and lateral resolution were 0.32mm and 1.37mm respectively, the imaging speed was up to 27 frames per second and the positioning accuracy was 9.2%.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
    Harput, Sevan
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    Ramalli, Alessandro
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Boni, Enrico
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (02) : 269 - 277
  • [2] Efficient Sample Delay Calculation for 2-D and 3-D Ultrasound Imaging
    Ibrahim, Aya
    Hager, Pascal A.
    Bartolini, Andrea
    Angiolini, Federico
    Arditi, Marcel
    Thiran, Jean-Philippe
    Benini, Luca
    De Micheli, Giovanni
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (04) : 815 - 831
  • [3] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Roux, Emmanuel
    Varray, Francois
    Petrusca, Lorena
    Cachard, Christian
    Tortoli, Piero
    Liebgott, Herve
    SCIENTIFIC REPORTS, 2018, 8
  • [4] Beamformer for a Lensed Row-Column Array in 3-D Ultrasound Imaging
    Salari, Ali
    Audoin, Melanie
    Tomov, Borislav Gueorguiev
    Yiu, Billy Y. S.
    Thomsen, Erik Vilain
    Arendt Jensen, Jorgen
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (02) : 238 - 250
  • [5] Assembling 2-D Blocks into 3-D Chips
    Knechtel, Johann
    Markov, Igor L.
    Lienig, Jens
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2012, 31 (02) : 228 - 241
  • [6] 3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [7] Fourier-Based Fast 3-D Ultrasound Imaging Using Row-Column-Addressed 2-D Arrays
    Lin, Shang-Ching
    Li, Pai-Chi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 85 - 101
  • [8] HYBRID BEAMFORMATION FOR VOLUMETRIC ULTRASOUND IMAGING SCANNERS USING 2-D ARRAY TRANSDUCERS
    Kim, Bae-Hyung
    Lee, Seungheun
    Kim, Youngil
    Cho, Kyungil
    Kim, Dongwook
    Song, Jongkeun
    2012 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2012), 2012, : 2297 - 2300
  • [9] Beamforming and Imageforming for 3D Ultrasound Imaging System using 2-D CMUT-on-ASIC Arrays
    Park, Suhyun
    Kim, Bae-Hyung
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Jeon, Taeho
    Song, Jongkeun
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1440 - 1443
  • [10] Switched Array Concepts for 3-D Radar Imaging
    Nelander, Anders
    2010 IEEE RADAR CONFERENCE, 2010, : 1019 - 1024