Evaluation of the effect of n95 face mask used by healthcare professionals on choroidal thickness

被引:8
作者
Durusoy, Gonul Karatas [1 ]
Gumus, Gulsah [1 ]
Demir, Gokhan [2 ]
机构
[1] Gaziantep Ersin Aslan Training & Res Hosp, Gaziantep, Turkey
[2] Univ Hlth Sci Fatih Sultan Mehmet Training & Res, Istanbul, Turkey
关键词
EDI-OCT; Choroidal thickness; Choroidal hemodynamics; Covid-19; N-95; mask; Hypercapnia; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-FLOW; MACULAR DEGENERATION; RESPIRATOR USE; AGE; PERFUSION; EYES;
D O I
10.1016/j.pdpdt.2021.102279
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We aimed to show the changes in choroidal thickness (CT) with spectral domain optical coherence tomography (SD-OCT) after prolonged use of N95 mask. Method: The healthcare workers who use the N95 face-mask, between 30-50 years of age who have best corrected visual acuity (BCVA) >= 10/10, spherical or cylindrical refraction errors less than 2 diopters, with normal intra ocular pressure (IOP), axial length (AL) between 22-24 mm included in the study. The choroid was imaged with enhanced depth imaging (EDI) techniques using SD-OCT. CT was measured, subfoveal, at 1000 um nasal and temporal of the center of the fovea. Measurements were first made after wearing the N95 mask for at least 2 h without removing it and repeated 15 min after removing. Results: After 2 h of the N95 mask using without removal, the mean subfoveal CT was 293.56 +/- 76.12(min:185, max:479), the mean temporal CT was 253.81 +/- 63.48(min:172, max:384), the mean nasal CT was 239.18 +/- 53.92(min:139, max:356). Fifteen minutes after removal of the N95 mask, the mean subfoveal CT was 250.56 +/- 52.48(min:172, max:397), the mean temporal was 218.40 +/- 53.58(min:129, max:354), the mean nasal CT was 210.67 +/- 53.31(min:132, max:366). The differences in subfoveal, temporal and nasal CT between 2 h of N95 mask use and 15 min after removal of the mask were statistically significant (p < 0.05 for each). Conclusion: Hypercapnia due to prolonged use of the N95 mask may cause choroidal hemodynamic changes and transient increased choroidal thickness.
引用
收藏
页数:4
相关论文
共 39 条
[11]  
Geiser MH, 2000, CURR EYE RES, V21, P669, DOI 10.1076/0271-3683(200008)21:2
[12]  
1-V
[13]  
FT669
[14]   Enhanced Depth Imaging Optical Coherence Tomography: Choroidal Thickness and Correlations With Age, Refractive Error, and Axial Length [J].
Goldenberg, Dafna ;
Moisseiev, Elad ;
Goldstein, Michaela ;
Loewenstein, Anat ;
Barak, Adiel .
OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (04) :296-301
[15]   Choroidal Thickness in Healthy Japanese Subjects [J].
Ikuno, Yasushi ;
Kawaguchi, Kana ;
Nouchi, Takeyoshi ;
Yasuno, Yoshiaki .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (04) :2173-2176
[16]   ENHANCED DEPTH IMAGING OPTICAL COHERENCE TOMOGRAPHY OF THE CHOROID IN CENTRAL SEROUS CHORIORETINOPATHY [J].
Imamura, Yutaka ;
Fujiwara, Takamitsu ;
Margolis, Ron ;
Spaide, Richard F. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (10) :1469-1473
[17]  
KIEL JW, 1995, INVEST OPHTH VIS SCI, V36, P579
[18]   COMPARISON OF CHOROIDAL THICKNESS AMONG PATIENTS WITH HEALTHY EYES, EARLY AGE-RELATED MACULOPATHY, NEOVASCULAR AGE-RELATED MACULAR DEGENERATION, CENTRAL SEROUS CHORIORETINOPATHY, AND POLYPOIDAL CHOROIDAL VASCULOPATHY [J].
Kim, Seong-Woo ;
Oh, Jaeryung ;
Kwon, Soon-Sun ;
Yoo, Junho ;
Huh, Kuhl .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (09) :1904-1911
[19]   Mechanisms of Parkinson's disease-related proteins in mediating secondary brain damage after cerebral ischemia [J].
Kim, TaeHee ;
Vemuganti, Raghu .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (06) :1910-1926
[20]   Choroidal thickness in both eyes of patients with unilaterally active central serous chorioretinopathy [J].
Kim, Y. T. ;
Kang, S. W. ;
Bai, K. H. .
EYE, 2011, 25 (12) :1635-1640