Fabrication of an Electrochemical E. coli Biosensor in Biowells Using Bimetallic Nanoparticle-Labelled Antibodies

被引:17
作者
Eksi, Haslet [1 ]
Guzel, Remziye [2 ]
Guven, Burcu [3 ]
Boyaci, Ismail Hakki [3 ]
Solak, Ali Osman [1 ,4 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, TR-06560 Ankara, Turkey
[2] Dicle Univ, Fac Educ, TR-21280 Diyarbakir, Turkey
[3] Hacettepe Univ, Food Res Ctr, TR-06800 Ankara, Turkey
[4] Kyrgyz Turkish Manas Univ, Fac Engn, Dept Chem Engn, Bishkek 720044, Kyrgyzstan
关键词
Bimetallic nanoparticles; E; coli; Anodic stripping voltammetry; Pencil graphite electrode; ANODIC-STRIPPING VOLTAMMETRY; SURFACE-ENHANCED RAMAN; GRAPHITE PENCIL ELECTRODE; CORE-SHELL NANOPARTICLES; METAL NANOPARTICLES; PASTE ELECTRODE; RAPID DETECTION; TRACE-METALS; IMMUNOASSAY; DNA;
D O I
10.1002/elan.201400370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor was developed for the determination of Escherichia coli (E. coli) in water. For this purpose, silver-gold core-shell (Ag@Au) bioconjugates and anti-E. coli modified PS-microwells were designed in a sandwich-type format in order to obtain higher sensitivity and selectivity. Ag@Au bimetallic nanoparticles were synthesized by co-reduction method. The core-shell formation was analyzed by using UV-Vis spectroscopy and transmission electron microscopy. Biotin labeled anti-E. coli antibodies were coupled with Ag@Au nanoparticles to form bioconjugates. The electrochemical immunosensor was prepared by immobilizing anti-E. coli on polystyrene (PS)-microwells via chemical bonding. These modified microwells were identified with X-ray photoelectron spectroscopy and surface enhanced Raman spectroscopy. E. coli was sandwiched between Ag@Au bioconjugates and anti-E. coli on PS-microwells at different concentrations. The relationship between the E. coli concentration and stripping current of gold ions (Au3+) were investigated by square wave anodic stripping voltammetry at pencil graphite electrode. The proposed method can provide some advantages such as lower detection limit and shorter detection time. The electrochemical response for the immunosensor was linear with the concentration of the E. coli in the range of 10(1) and 10(5) cfu/mL with a limit of detection 3 cfu/mL. The procedure maintains good sensitivity and repeatability and also offers utility in the fields of environmental monitoring and clinical diagnosis.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 42 条
[1]   Highly sensitive amperometric immunosensor for the detection of Escherichia coli [J].
Abu-Rabeah, K. ;
Ashkenazi, A. ;
Atias, D. ;
Amir, L. ;
Marks, R. S. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3461-3466
[2]   Differential pulse adsorptive stripping voltammetric determination of nanomolar levels of methotrexate utilizing bismuth film modified electrodes [J].
Asbahr, Deborah ;
Figueiredo-Filho, Luiz Carlos S. ;
Vicentini, Fernando Campanha ;
Oliveira, Geiser Gabriel ;
Fatibello-Filho, Orlando ;
Banks, Craig E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 :334-339
[3]   Magnetic gold nanoparticles in SERS-based sandwich immunoassay for antigen detection by well oriented antibodies [J].
Baniukevic, Julija ;
Boyaci, Ismail Hakki ;
Bozkurt, Akif Goktug ;
Tamer, Ugur ;
Ramanavicius, Arunas ;
Ramanaviciene, Almira .
BIOSENSORS & BIOELECTRONICS, 2013, 43 :281-288
[4]  
Bard AJ, 2001, ELECTROCHEMICAL METH
[5]   Conditioning of renewable silver amalgam film electrode for the characterization of clothianidin and its determination in selected samples by adsorptive square-wave voltammetry [J].
Brycht, Mariola ;
Skrzypek, Slawomira ;
Guzsvany, Valeria ;
Berenji, Janos .
TALANTA, 2013, 117 :242-249
[6]   Core/Shell Nanoparticles: Classes, Properties, Synthesis Mechanisms, Characterization, and Applications [J].
Chaudhuri, Rajib Ghosh ;
Paria, Santanu .
CHEMICAL REVIEWS, 2012, 112 (04) :2373-2433
[7]   An electrochemical amplification immunoassay using biocatalytic metal deposition coupled with anodic stripping voltammetric detection [J].
Chen, Zhao-Peng ;
Peng, Zhao-Feng ;
Jiang, Jian-Hui ;
Zhang, Xiao-Bing ;
Shen, Guo-Li ;
Yu, Ru-Qin .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) :146-151
[8]   Synthesis of AgcoreAushell bimetallic nanoparticles for immunoassay based on surface-enhanced Raman spectroscopy [J].
Cui, Y ;
Ren, B ;
Yao, JL ;
Gu, RA ;
Tian, ZQ .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (09) :4002-4006
[9]   Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode [J].
El Harmoudi, H. ;
Achak, M. ;
Farahi, A. ;
Lahrich, S. ;
El Gaini, L. ;
Abdennouri, M. ;
Bouzidi, A. ;
Bakasse, M. ;
El Mhammedi, M. A. .
TALANTA, 2013, 115 :172-177
[10]  
Ezzati J., 2014, ANAL METHODS, DOI [10.1039/C3AY41749B, DOI 10.1039/C3AY41749B]