Evaluation of the influence of patient positioning on the reliability of lateral cephalometry

被引:8
作者
David, Ovidiu-Tiberiu [1 ]
Tuce, Robert-Angelo [1 ]
Munteanu, Oana [1 ]
Neagu, Adrian [1 ,2 ]
Panainte, Irinel [3 ]
机构
[1] Victor Babes Univ Med & Pharm Timisoara, Ctr Modeling Biol Sysems & Data Anal, Piata Eftimie Murgu 2-4, Timisoara 300041, Romania
[2] Univ Missouri, Dept Phys & Astron, Columbia, MO 65211 USA
[3] Univ Med & Pharm Targu Mures, Targu Mures, Romania
来源
RADIOLOGIA MEDICA | 2017年 / 122卷 / 07期
关键词
Interobserver agreement; Intraobserver agreement; Lateral cephalograms; Subject posture; HEAD; DIFFERENCE;
D O I
10.1007/s11547-017-0748-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional cephalometry is widely used for monitoring orthodontic treatments and for quantifying the outcome of maxillofacial surgery. Despite careful use of a cephalostat, successive radiographs might differ due to slight differences in patient posture. This study evaluates the reliability of lateral cephalometric measurements and estimates the impact of patient positioning on this reliability. We studied cephalograms of 104 patients; 31 of them had two radiographs because the first was deemed unsuitable for cephalometric analysis. Using AudaxCeph 3.0 (Audax, Ljubljana, Slovenia), two observers traced each cephalogram twice, one month apart. We evaluated intra- and interobserver agreement via Bland-Altman analysis, intraclass correlation coefficient (ICC), standard error of measurement, and smallest detectable difference (SDD). First, we studied the reliability of the hard tissue part of the Tweed-Merrifield analysis for 73 single cephalograms and for the better ones of patients with two exposures. Then, we studied 31 unsatisfactory cephalograms, and the ones recorded at improved patient posture. Although intraobserver bias was less than 0.5 degrees or 0.3 mm, interobserver bias was significant for most measurements. Intraobserver reliability was high (ICC > 0.9), whereas interobserver reliability was good (ICC > 0.83) except for FMPA, FMIA and OP. Head rotations and inclinations had little impact on reliability (e.g., interobserver SDD decreased for 3 of 11 measurements). We conclude that averaging the positions of bilateral structures enables a reliable cephalometric analysis in spite of imprecise patient posture. Retaking cephalograms is ethically questionable in such cases.
引用
收藏
页码:520 / 529
页数:10
相关论文
共 26 条
[1]  
Ahlqvist J, 1983, Dentomaxillofac Radiol, V12, P101
[2]  
AHLQVIST J, 1988, EUR J ORTHODONT, V10, P353
[3]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[4]   Effects of head positioning on cephalometric measurements Head position and cephalometric values [J].
Berneburg, M. ;
Koos, B. ;
Kratochwil, R. ;
Godt, A. .
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2012, 73 (06) :477-485
[5]  
Blanc M, 1997, Radiol Med, V94, P302
[6]  
Bland M. J., 1986, LANCET, V327, P307, DOI 10.1016/S0140-6736(86)90837-8
[7]   On the growth pattern of the human head - From the third month to the eighth year of life [J].
Brodie, AG .
AMERICAN JOURNAL OF ANATOMY, 1941, 68 (02) :209-262
[8]   Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images [J].
Damstra, Janalt ;
Fourie, Zacharias ;
Slater, James J. R. Huddleston ;
Ren, Yijin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) :E107-E114
[9]   Reliability and the smallest detectable differences of lateral cephalometric measurements EDITOR'S COMMENT [J].
Damstra, Janalt ;
Slater, James J. R. Huddleston ;
Fourie, Zacharias ;
Ren, Yijin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (05) :546-547
[10]   How to report reliability in orthodontic research: Part 1 [J].
Donatelli, Richard E. ;
Lee, Shin-Jae .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (01) :156-161