T1 and T2 measurements of the fine structures of the in vivo and enucleated human eye

被引:32
作者
Patz, Samuel
Bert, Robert J.
Frederick, Eric
Freddo, Thomas F.
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Tufts Univ New England Med Ctr, Dept Radiol, Boston, MA USA
[3] Univ Colorado, Hlth Sci Ctr, Dept Radiol, Denver, CO 80202 USA
[4] Univ Massachusetts, Dept Phys, Lowell, MA USA
[5] Boston Univ, Sch Med, Dept Ophthalmol, Boston, MA 02118 USA
[6] Univ Waterloo, Sch Optometry, Waterloo, ON N2L 3G1, Canada
[7] Boston Univ, Sch Med, Dept Pathol, Boston, MA 02118 USA
关键词
T-1; T-2; ocular tissues; eye; relaxation times; in vivo;
D O I
10.1002/jmri.21017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure T-1 and T-2 of the fine structures of the in vivo eye. Materials and Methods: Involuntary saccades make it difficult to obtain artifact-free images. Using a method recently reported (Bert et al, Acad Radiol 2006; 12:368-378), near artifact-free spin-echo images were obtained. Both an isolated enucleated eye and eight human subjects were studied at 1.5T. Spin-echo variable TRITE data was acquired for T-1/T-2 determination. Average relaxation times were calculated two ways. First, an arithmetic average over different subjects was computed. Second, all data was normalized using the fitted amplitudes of each data set and pooled to obtain a single least squares fit. Results: In vivo T-1/T-2 (msec) are: arithmetic average T-1, T-2, normalized data T1, T2. Anterior chamber: 6233 +/- 979, 468 +/- 149, 5053 +/- 1052, 450 1 +/- 49. Ciliary body: 1916 +/- 184, 80 +/- 7, 2038 +/- 114, 76 +/- 3. Chorioretina: 1717 +/- 500, 72 +/- 25, 1511 1 +/- 230, 78 +/- 3. Extraocular muscle: 1581 +/- 646, 41 +/- 7, 1470 +/- 231, 41 +/- 1. Iris: 3334 +/- 989, 163 +/- 63, 3376 +/- 338, 153 +/- 10. Lens cortex: 1712 +/- 466, 93 +/- 36, 1413 +/- 177, 100 +/- 5. Lens nucleus: 1133 +/- 40, 26 +/- 3, 1138 +/- 47, 25 +/- 0.4. Optic nerve: 1906 +/- 301, 6816, 1805 +/- 244, 71 +/- 2. Posterior chamber: 7915 +/- 4897, 241 +/- 14, 3323 +/- 2154, 251 +/- 38. Vitreous humor: 5768 +/- 1190, 756 +/- 804, 4855 +/- 1846, 390 +/- 8. Conclusion: In vivo T-1 and T-2 for many of the fine structures of the human eye have been measured.
引用
收藏
页码:510 / 518
页数:9
相关论文
共 50 条
  • [41] Repeatability of radiomic features in myocardial T1 and T2 mapping
    Manzke, Mathias
    Laqua, Fabian C.
    Boettcher, Benjamin
    Klemenz, Ann-Christin
    Weber, Marc-Andre
    Baessler, Bettina
    Meinel, Felix G.
    EUROPEAN RADIOLOGY, 2025, 35 (03) : 1570 - 1582
  • [42] Paramagnetic nanoparticle T1 and T2 MRI contrast agents
    Xu, Wenlong
    Kattel, Krishna
    Park, Ja Young
    Chang, Yongmin
    Kim, Tae Jeong
    Lee, Gang Ho
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (37) : 12687 - 12700
  • [43] Modeling T1 and T2 relaxation in bovine white matter
    Barta, R.
    Kalantari, S.
    Laule, C.
    Vavasour, I. M.
    MacKay, A. L.
    Michal, C. A.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 259 : 56 - 67
  • [44] Myocardial T1 and T2 mapping in diastolic and systolic phase
    Tessa, Carlo
    Diciotti, Stefano
    Landini, Nicholas
    Lilli, Alessio
    Del Meglio, Jacopo
    Salvatori, Luca
    Giannelli, Marco
    Greiser, Andreas
    Vignali, Claudio
    Casolo, Giancarlo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (05) : 1001 - 1010
  • [45] Regional variation in T1ρ and T2 times in osteoarthritic human menisci: correlation with mechanical properties and matrix composition
    Son, M.
    Goodman, S. B.
    Chen, W.
    Hargreaves, B. A.
    Gold, G. E.
    Levenston, M. E.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (06) : 796 - 805
  • [46] Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging
    Yoo, Yeon Hwa
    Yoon, Choon-Sik
    Eun, Na Lae
    Hwang, Moon-Jung
    Yoo, Hanna
    Peters, Robert D.
    Chung, Tae-Sub
    Lee, Young Han
    Suh, Jin-Suck
    Kim, Sungjun
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (06) : 903 - 911
  • [47] T1, T2 relaxation and magnetization transfer in tissue at 3T
    Stanisz, GJ
    Odrobina, EE
    Pun, J
    Escaravage, M
    Graham, SJ
    Bronskill, MJ
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 507 - 512
  • [48] Classification of Coronary Atherosclerotic Plaques Ex Vivo With T1, T2, and Ultrashort Echo Time CMR
    Karolyi, Mihaly
    Seifarth, Harald
    Liew, Gary
    Schlett, Christopher L.
    Maurovich-Horvat, Pal
    Stolzmann, Paul
    Dai, Guangping
    Huang, Shuning
    Goergen, Craig J.
    Nakano, Masataka
    Otsuka, Fumiyuki
    Virmani, Renu
    Hoffmann, Udo
    Sosnovik, David E.
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (04) : 466 - 474
  • [49] Quantitative T1, T2, and T2 * Mapping and Semi-Quantitative Neuromelanin-Sensitive Magnetic Resonance Imaging of the Human Midbrain
    Hashido, Takashi
    Saito, Shigeyoshi
    PLOS ONE, 2016, 11 (10):
  • [50] Validation and Optimization of Adiabatic T1ρ and T2ρ for Quantitative Imaging of Articular Cartilage at 3T
    Casula, Victor
    Autio, Joonas
    Nissi, Mikko J.
    Auerbach, Edward J.
    Ellermann, Jutta
    Lammentausta, Eveliina
    Nieminen, Miika T.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1265 - 1275