T1 and T2 measurements of the fine structures of the in vivo and enucleated human eye

被引:32
作者
Patz, Samuel
Bert, Robert J.
Frederick, Eric
Freddo, Thomas F.
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Tufts Univ New England Med Ctr, Dept Radiol, Boston, MA USA
[3] Univ Colorado, Hlth Sci Ctr, Dept Radiol, Denver, CO 80202 USA
[4] Univ Massachusetts, Dept Phys, Lowell, MA USA
[5] Boston Univ, Sch Med, Dept Ophthalmol, Boston, MA 02118 USA
[6] Univ Waterloo, Sch Optometry, Waterloo, ON N2L 3G1, Canada
[7] Boston Univ, Sch Med, Dept Pathol, Boston, MA 02118 USA
关键词
T-1; T-2; ocular tissues; eye; relaxation times; in vivo;
D O I
10.1002/jmri.21017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure T-1 and T-2 of the fine structures of the in vivo eye. Materials and Methods: Involuntary saccades make it difficult to obtain artifact-free images. Using a method recently reported (Bert et al, Acad Radiol 2006; 12:368-378), near artifact-free spin-echo images were obtained. Both an isolated enucleated eye and eight human subjects were studied at 1.5T. Spin-echo variable TRITE data was acquired for T-1/T-2 determination. Average relaxation times were calculated two ways. First, an arithmetic average over different subjects was computed. Second, all data was normalized using the fitted amplitudes of each data set and pooled to obtain a single least squares fit. Results: In vivo T-1/T-2 (msec) are: arithmetic average T-1, T-2, normalized data T1, T2. Anterior chamber: 6233 +/- 979, 468 +/- 149, 5053 +/- 1052, 450 1 +/- 49. Ciliary body: 1916 +/- 184, 80 +/- 7, 2038 +/- 114, 76 +/- 3. Chorioretina: 1717 +/- 500, 72 +/- 25, 1511 1 +/- 230, 78 +/- 3. Extraocular muscle: 1581 +/- 646, 41 +/- 7, 1470 +/- 231, 41 +/- 1. Iris: 3334 +/- 989, 163 +/- 63, 3376 +/- 338, 153 +/- 10. Lens cortex: 1712 +/- 466, 93 +/- 36, 1413 +/- 177, 100 +/- 5. Lens nucleus: 1133 +/- 40, 26 +/- 3, 1138 +/- 47, 25 +/- 0.4. Optic nerve: 1906 +/- 301, 6816, 1805 +/- 244, 71 +/- 2. Posterior chamber: 7915 +/- 4897, 241 +/- 14, 3323 +/- 2154, 251 +/- 38. Vitreous humor: 5768 +/- 1190, 756 +/- 804, 4855 +/- 1846, 390 +/- 8. Conclusion: In vivo T-1 and T-2 for many of the fine structures of the human eye have been measured.
引用
收藏
页码:510 / 518
页数:9
相关论文
共 50 条
  • [21] Quantitative Spectroscopic Imaging with In Situ Measurements of Tissue Water T1, T2, and Density
    Gasparovic, C.
    Neeb, H.
    Feis, D. L.
    Damaraju, E.
    Chen, H.
    Doty, M. J.
    South, D. M.
    Mullins, P. G.
    Bockholt, H. J.
    Shah, N. J.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 583 - 590
  • [22] Reproducibility of myocardial T1 and T2 relaxation time measurement using slice-interleaved T1 and T2 mapping sequences
    Bellm, Steven
    Basha, Tamer A.
    Shah, Ravi V.
    Murthy, Venkatesh L.
    Liew, Charlene
    Tang, Maxine
    Ngo, Long H.
    Manning, Warren J.
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (05) : 1159 - 1167
  • [23] Prediction of glycosaminoglycan content in human cartilage by age, T1ρ and T2 MRI
    Keenan, K. E.
    Besier, T. F.
    Pauly, J. M.
    Han, E.
    Rosenberg, J.
    Smith, R. L.
    Delp, S. L.
    Beaupre, G. S.
    Gold, G. E.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 (02) : 171 - 179
  • [24] Comparison of MRI T1, T2, and T2*mapping with histology for assessment of intervertebral disc degeneration in an ovine model
    Bouhsina, Nora
    Decante, Cyrille
    Hardel, Jean-Baptiste
    Rouleau, Dominique
    Abadie, Jerome
    Hamel, Antoine
    Le Visage, Catherine
    Lesoeur, Julie
    Guicheux, Jerome
    Clouet, Johann
    Fusellier, Marion
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [25] Effects of supplemental oxygen on cardiovascular magnetic resonance water proton relaxation time constant measurements (T1, T2 and T2*)
    Goldfarb, James W.
    Hsu, Brittany
    Cao, Jie J.
    MAGNETIC RESONANCE IMAGING, 2019, 61 : 124 - 130
  • [26] Simultaneous determination of metabolite concentrations, T1 and T2 relaxation times
    An, Li
    Li, Shizhe
    Shen, Jun
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2072 - 2081
  • [27] Efficiency analysis for quantitative MRI of T1 and T2 relaxometry methods
    Leitao, David
    Teixeira, Rui Pedro A. G.
    Price, Anthony
    Uus, Alena
    Hajnal, Joseph, V
    Malik, Shaihan J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (15)
  • [28] On (T1, T2)-R1 bitopological spaces
    Kong-ied, Butsakorn
    Sompong, Supannee
    Boonpok, Chawalit
    INTERNATIONAL JOURNAL OF MATHEMATICS AND COMPUTER SCIENCE, 2024, 19 (03) : 827 - 832
  • [29] Measurements of T1 and T2 relaxation times of colon cancer metastases in rat liver at 7 T
    G. Gambarota
    A. Veltien
    H. van Laarhoven
    M. Philippens
    A. Jonker
    O. R. Mook
    W. M. Frederiks
    A. Heerschap
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 17 : 281 - 287
  • [30] T1ρ, T2 and T2*mapping of lumbar intervertebral disc degeneration: a comparison study
    Yang, Li
    Sun, Cong
    Gong, Tao
    Li, Quanlin
    Chen, Xin
    Zhang, Xinjuan
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)