Non-Pilot Protection of the Inverter-Dominated Microgrid

被引:10
作者
Lahiji, Houman [1 ]
Ajaei, Firouz Badrkhani [1 ]
Boudreau, Ryan E. [2 ]
机构
[1] Western Univ, Elect & Comp Engn Dept, London, ON N6A 5B9, Canada
[2] Hydro One Networks Inc, Protect & Automat Dept, Toronto, ON M5G 1P5, Canada
来源
IEEE ACCESS | 2019年 / 7卷
关键词
Inverter-dominated microgrid; protection; relay; fault detection; negative-sequence directional element; STRATEGY; SCHEME;
D O I
10.1109/ACCESS.2019.2944137
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Without utilizing costly communication systems, the existing protection strategies fail to reliably detect the occurrence and direction of faults in the inverter-dominated microgrid. To address this issue, this paper introduces a selective and reliable non-pilot protection strategy for the inverter-dominated microgrid. The proposed protection strategy (i) does not require communication signals, (ii) incorporates phase- and sequence-domain protective elements for reliable detection of symmetrical and asymmetrical faults, (iii) improves the existing sequence-domain directional elements and effectively utilizes them for accurate determination of the fault direction in the presence of inverter-interfaced distributed energy resources, (iv) selectively protects the inverter-dominated microgrid against internal and external faults, (v) is robust against the grid-connection mode of the microgrid, and (vi) enables fuse protection of laterals and non-critical circuits. The acceptable performance of the proposed protection strategy is verified through comprehensive fault studies conducted on a realistic study system simulated in the PSCAD/EMTDC software environment. This paper also demonstrates that the proposed protection strategy can be implemented using an off-the-shelf digital relay.
引用
收藏
页码:142190 / 142202
页数:13
相关论文
共 41 条
[1]  
Abbasi E., 2016, PROB METH APPL POW S, P1
[2]  
Abdel-Galil T. K., 2007, CETC200714920070914
[3]  
Al-Nasseri H., 2006, 2006 IEEE Power Engineering Society General Meeting, P7, DOI 10.1109/pes.2006.1709423
[4]  
[Anonymous], 2019, SEL351567
[5]  
[Anonymous], 1979, GET6450
[6]  
[Anonymous], 2011, MED VOLT EXP FUS BA
[7]  
[Anonymous], 1997, SEL RTS REL TEST SYS
[8]  
Calero F, 2004, ANN CONF PROTECT REL, P190
[9]   Active and Reactive Power Strategies With Peak Current Limitation for Distributed Generation Inverters During Unbalanced Grid Faults [J].
Camacho, Antonio ;
Castilla, Miguel ;
Miret, Jaume ;
Borrell, Angel ;
Garcia de Vicuna, Luis .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) :1515-1525
[10]  
Chen B, 2015, ANN CONF PROTECT REL, P335, DOI 10.1109/CPRE.2015.7102177