Optimization of Continuous Post-Tensioned Concrete Bridge Girders of Non-Uniform Depth

被引:5
|
作者
Al-Osta, Mohammed A. [1 ]
Azad, Abul K. [1 ]
Al-Gahtani, Husain J. [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Civil Engn, Dhahran 31261, Saudi Arabia
来源
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING | 2012年 / 37卷 / 02期
关键词
Bridges; Optimization; Post-tensioning; Prestressing force; Prestressing steel; Structures; COST;
D O I
10.1007/s13369-012-0169-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Post-tensioned single-cell concrete box girders of variable depth are used in continuous bridges to achieve both economy and aesthetics. In this paper, the minimum prestressing for a given two- or three-span continuous bridge deck profile is achieved through a constrained optimization procedure using linear programming in conjunction with gradient method of optimization. The constrained nonlinear problem is solved by transforming it to a linear one by introducing a new design variable which proportions long (full length) and short tendons. A gradient search technique is used to solve iteratively the optimization problem. The design variables include interior to exterior span ratio (for three-span), the depth profile of the cross-section, tendon profile, and prestressing force. The total cost of the member is taken as the cost of structural materials (concrete and prestressing steel), excluding the cost of formwork. The design constraints are the prescribed limits on the allowable stresses, ultimate strength, and serviceability requirements as per ACI 343R-95. A purpose-built computer program has been developed to readily determine the optimum prestressing for a given bridge deck profile. From solutions of a number of hypothetical bridge girders using AASHTO H20 bridge loading, several useful results related to design are obtained. Results show that for a symmetrical three-span and two-span continuous bridge girder, the optimum prestressing consists of an optimum arrangement of both long and short tendons, and for a three-span girder of prescribed length, the optimum design is attained at an optimum ratio of interior to exterior span with 1.35 to 1.45.
引用
收藏
页码:265 / 276
页数:12
相关论文
共 50 条
  • [21] Preliminary Design of Post-Tensioned Transfer Girders
    Uzel, Almila
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2020, 25 (04)
  • [22] Optimization of post-tensioned concrete slabs for minimum cost
    Zelickman, Yakov
    Amir, Oded
    ENGINEERING STRUCTURES, 2022, 259
  • [23] Semi-probabilistic nonlinear assessment of post-tensioned concrete bridge made of KT-24 girders
    Splichal, B.
    Lehky, D.
    Dolezel, J.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 417 - 418
  • [24] Layout optimization of post-tensioned cables in concrete slabs
    Zelickman, Yakov
    Amir, Oded
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2021, 63 (04) : 1951 - 1974
  • [25] Layout optimization of post-tensioned cables in concrete slabs
    Yakov Zelickman
    Oded Amir
    Structural and Multidisciplinary Optimization, 2021, 63 : 1951 - 1974
  • [26] An Efficient Post-Tensioned Prestressed Concrete Bridge Construction Approach
    Li, Shilan
    2019 11TH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2019), 2019, : 128 - 131
  • [27] GPR detection of voids in post-tensioned concrete bridge beams
    Giannopoulos, A
    Macintyre, P
    Rodgers, S
    Forde, MC
    GPR 2002: NINTH INTERNATIONAL CONFERENCE ON GROUND PENETRATING RADAR, 2002, 4758 : 376 - 381
  • [28] Testing of post-tensioned concrete girders in the framework of monitoring with fibre optic sensors
    Matthys, S
    Taerwe, L
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2003, : 321 - 328
  • [29] Experimental Investigation of Segmental Post-tensioned Girders
    Allawi, Abbas
    Al-Sherrawi, Mohannad
    AL-Bayati, Basim
    Al Gharawi, Mohanned
    El-Zohairy, Ayman
    CHALLENGES IN MECHANICS OF TIME-DEPENDENT MATERIALS (2018), VOL 2, 2019, : 87 - 94
  • [30] Experimental testing of post-tensioned concrete girders instrumented with optical fibre gratings
    Matthys, S
    Taerwe, L
    17TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2005, 5855 : 1060 - 1063