Reciprocal-FDK reconstruction for x-ray diffraction computed tomography

被引:2
|
作者
Liang, Kaichao [1 ,2 ]
Zhang, Li [1 ,2 ]
Xing, Yuxiang [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing, Peoples R China
关键词
x-ray diffraction computed tomography; FDK reconstruction; cone-angle artifacts; SCATTERING; CLASSIFICATION; ALGORITHM;
D O I
10.1088/1361-6560/ac5bf9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. X-ray diffraction (XRD) technology uses x-ray small-angle scattering signal for material analysis, which is highly sensitive to material inter-molecular structure. To meet the high spatial resolution requirement in applications such as medical imaging, XRD computed tomography (XRDCT) has been proposed to provide XRD intensity with improved spatial resolution from point-wise XRD scan. In XRDCT, 2D spatial tomography corresponds to a 3D reconstruction problem with the third dimension being the XRD spectrum dimension, i.e. the momentum transfer dimension. Current works in the field have studied reconstruction methods for either angular-dispersive XRDCT or energy-dispersive XRDCT for small samples. The approximations used are only suitable for regions near the XRDCT iso-center. A new XRDCT reconstruction method is needed for more general imaging applications. Approach. We derive a new FDK-type reconstruction method (Reciprocal-FDK) for XRDCT without limitation on object size. By introducing a set of reciprocal variables, the XRDCT model is transformed into a classical cone-parallel CT model, which is an extension of a circular-trajectory cone-beam CT model, after which the FDK method is applied for XRDCT reconstruction. Main results. Both analytical simulation and Monte Carlo simulation experiments are conducted to validate the XRDCT reconstruction method. The results show that when compared to existing analytical reconstruction methods, there are improvements in the proposed Reciprocal-FDK method with regard to relative structure reconstruction and XRD pattern peak reconstruction. Since cone-parallel CT does not satisfy the data completeness condition, cone-angle effect affects the reconstruction accuracy of XRDCT. The property of cone-angle effect in XRDCT is also analyzed with ablation studies. Significance. We propose a general analytical reconstruction method for XRDCT without constraint on object size. Reciprocal-FDK provides a complete derivation and theoretical support for XRDCT reconstruction by analogy to the well-studied cone-parallel CT model. In addition, the intrinsic problem with the XRDCT data model and the corresponding reconstruction error are discussed for the first time.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] A Joint Reconstruction and Segmentation Method for Limited-Angle X-Ray Tomography
    Wei, Zenghui
    Liu, Baodong
    Dong, Bin
    Wei, Long
    IEEE ACCESS, 2018, 6 : 7780 - 7791
  • [42] X-ray microbeam diffraction in a crystal
    Punegov, Vasily, I
    Karpov, Andrey, V
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : 117 - 125
  • [43] A new theory for X-ray diffraction
    Fewster, Paul F.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : 257 - 282
  • [44] X-ray-induced acoustic computed tomography (XACT) imaging with single-shot nanosecond x-ray
    Wang, Siqi
    Ivanov, Vassili
    Pandey, Prabodh Kumar
    Xiang, Liangzhong
    APPLIED PHYSICS LETTERS, 2021, 119 (18)
  • [45] Instrument-model refinement in normalized reciprocal-vector space for X-ray Laue diffraction
    Kaminski, Radoslaw
    Szarejko, Dariusz
    Pedersen, Martin N.
    Hatcher, Lauren E.
    Laski, Piotr
    Raithby, Paul R.
    Wulff, Michael
    Jarzembska, Katarzyna N.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2020, 53 : 1370 - 1375
  • [46] Hybrid Simplified Spherical Harmonics with Diffusion Equation for X-Ray Luminescence Computed Tomography
    Zhao, Hengna
    Fan, Jingxiao
    Guo, Hongbo
    Hou, Yuqing
    He, Xiaowei
    IMAGE AND GRAPHICS, ICIG 2019, PT II, 2019, 11902 : 568 - 580
  • [47] Prior-Guided Metal Artifact Reduction for Iterative X-Ray Computed Tomography
    Chang, Zhiqian
    Ye, Dong Hye
    Srivastava, Somesh
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1532 - 1542
  • [48] Refinement of clinical X-ray computed tomography (CT) scans containing metal implants
    Treece, Graham
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2017, 56 : 11 - 23
  • [49] X-ray computed tomography for non-destructive analysis of early Medieval swords
    Stelzner, Joerg
    Gauss, Florian
    Schuetz, Philipp
    STUDIES IN CONSERVATION, 2016, 61 (02) : 86 - 101
  • [50] High-kVp Assisted Metal Artifact Reduction for X-Ray Computed Tomography
    Xi, Yan
    Jin, Yannan
    De Man, Bruno
    Wang, Ge
    IEEE ACCESS, 2016, 4 : 4769 - 4776