Implantable cardioverter-defibrillators improve survival after coronary artery bypass grafting in patients with severely impaired left ventricular function

被引:8
作者
Al-Dadah, Ashraf S. [1 ]
Voeller, Rochus K. [1 ]
Rahgozar, Paymon [1 ]
Lawton, Jennifer S. [1 ]
Moon, Marc R. [1 ]
Pasque, Michael K. [1 ]
Damiano, Ralph J., Jr. [1 ]
Moazami, Nader [1 ]
机构
[1] Washington Univ, Sch Med, Dept Surg, Div Cardiothorac Surg, St Louis, MO 63110 USA
关键词
Ventricular Tachycardia; Sudden Cardiac Death; Ventricular Tachyarrhythmia; Severe Left Ventricular Dysfunction; CABG Surgery;
D O I
10.1186/1749-8090-2-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Patients with severe left ventricular (LV) dysfunction have a poor long term survival despite complete surgical revascularization. Recent data suggests that the use of Implantable Cardioverter-Defibrillator (ICD) improves survival in patients with severe LV dysfunction. We compared the survival impact of ICD implantation in patients with severe LV dysfunction who underwent CABG. Methods: Between January 1996 and August 2004, 305 patients with LV ejection fraction (EF) <= 25% had CABG surgery at our institution. Demographics of patients who had received an ICD (ICD+) in the post - operative period was compared to those without ICD (ICD-). Survival was evaluated by the Kaplan-Meier method. Results: Of the entire group, 35 (11.5%) patients received an ICD with a median of 2 (+/-2) years after CABG. Indication for ICD implantation was clinical evidence of non sustained ventricular tachycardia (NSVT). There were no differences between the 2 groups with respect to age, gender, NYHA classification, number of bypasses, or other co-morbidities. Survival at 1, 3 and 5 years was 88%, 79%, and 67% for the ICD- group compared to 94%, 89% and 83% for the ICD+ group, respectively (figure, p < 0.05). Conclusion: Implantation of ICD after CABG confers improved short and long term survival benefit to patients with severe LV dysfunction. Prophylactic ICD implantation in the setting of severe LV dysfunction and CABG surgery should be considered.
引用
收藏
页数:7
相关论文
共 50 条
[31]   Circadian pattern of life-threatening ventricular arrhythmia in patients with sleep-disordered breathing and implantable cardioverter-defibrillators [J].
Zeidan-Shwiri, Tawfiq ;
Aronson, Doron ;
Atalla, Khalid ;
Blich, Miry ;
Suleiman, Mahmoud ;
Marai, Ibrahim ;
Gepstein, Lior ;
Lavie, Lena ;
Lavie, Peretz ;
Boulos, Monther .
HEART RHYTHM, 2011, 8 (05) :657-662
[32]   Amino-terminal pro-brain natriuretic peptide predicts ventricular arrhythmogenesis in patients with ischemic cardiomyopathy and implantable cardioverter-defibrillators [J].
Manios, EG ;
Kallergis, EM ;
Kanoupakis, EM ;
Mavrakis, HE ;
Kambouraki, DC ;
Arfanakis, DA ;
Vardas, PE .
CHEST, 2005, 128 (04) :2604-2610
[33]   Ventricular arrhythmias following coronary artery bypass grafting for ischemic cardiomyopathy: When to insert an implanted cardioverter defibrillator? [J].
Nakae, Masaro ;
Kainuma, Satoshi ;
Toda, Koichi ;
Yoshioka, Daisuke ;
Kawamura, Takuji ;
Kawamura, Ai ;
Kashiyama, Noriyuki ;
Komukai, Sho ;
Kitamura, Tetsuhisa ;
Hirayama, Atsushi ;
Shimomura, Yoshimitsu ;
Taniguchi, Kazuhiro ;
Miyagawa, Shigeru .
JTCVS OPEN, 2023, 13 :163-175
[34]   Temporary ventricular overdrive pacing for electrical storm after coronary artery bypass grafting [J].
Yoshida T. ;
Naito Y. ;
Nishimura K. .
General Thoracic and Cardiovascular Surgery, 2011, 59 (11) :756-759
[35]   Clinical Impact of Circulating Galectin-3 on Ventricular Arrhythmias and Heart Failure Hospitalization Independent of Prior Ventricular Arrhythmic Events in Patients with Implantable Cardioverter-defibrillators [J].
Makimoto, Hisaki ;
Muller, Patrick ;
Denise, Kullmann ;
Clasen, Lukas ;
Lin, Tina ;
Angendohr, Stephan ;
Schmidt, Jan ;
Brinkmeyer, Christoph ;
Kelm, Malte ;
Bejinariu, Alexandru .
INTERNAL MEDICINE, 2022, 61 (07) :969-977
[36]   Improvement of left ventricular function with surgical revascularization in patients eligible for implantable cardioverter-defibrillator [J].
Adabag, Selcuk ;
Carlson, Selma ;
Gravely, Amy ;
Buelt-Gebhardt, Melissa ;
Madjid, Mohammad ;
Naksuk, Niyada .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (02) :244-251
[37]   Effective treatment of electrical storm by a wearable cardioverter defibrillator in a patient with severely impaired left ventricular function after myocardial infarction: a case report [J].
Henrike Andresen ;
B. Sasko ;
D. Patschan ;
N. Pagonas ;
O. Ritter .
Journal of Medical Case Reports, 15
[38]   Effective treatment of electrical storm by a wearable cardioverter defibrillator in a patient with severely impaired left ventricular function after myocardial infarction: a case report [J].
Andresen, Henrike ;
Sasko, B. ;
Patschan, D. ;
Pagonas, N. ;
Ritter, O. .
JOURNAL OF MEDICAL CASE REPORTS, 2021, 15 (01)
[39]   Effectiveness of antitachycardia pacing therapy after primary prophylaxis implantation of implantable defibrillators in coronary artery disease patients [J].
Maciag, Aleksander ;
Przybylski, Andrzej ;
Sterlinski, Maciej ;
Lewandowski, Michal ;
Gepner, Katarzyna ;
Syska, Pawel ;
Pytkowski, Mariusz ;
Smolis-Bak, Edyta ;
Szwed, Hanna .
ADVANCES IN MEDICAL SCIENCES, 2014, 59 (02) :161-165
[40]   Device artifact reduction for magnetic resonance imaging of patients with implantable cardioverter-defibrillators and ventricular tachycardia: Late gadolinium enhancement correlation with electroanatomic mapping [J].
Stevens, Steven M. ;
Tung, Roderick ;
Rashid, Shams ;
Gima, Jean ;
Cote, Shelly ;
Pavez, Geraldine ;
Khan, Sarah ;
Ennis, Daniel B. ;
Finn, J. Paul ;
Boyle, Noel ;
Shivkumar, Kalyanam ;
Hu, Peng .
HEART RHYTHM, 2014, 11 (02) :289-298