Ruby-based inorganic scintillation detectors for 192Ir brachytherapy

被引:16
作者
Kertzscher, Gustavo [1 ]
Beddar, Sam [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Grad Sch Biomed Sci Houston, Houston, TX 77030 USA
关键词
ruby; inorganic scintillation detector; brachytherapy; in vivo dosimetry; high dose rate brachytherapy; Ir-192; IN-VIVO DOSIMETRY; LUMINESCENCE DOSIMETRY; TEMPERATURE-DEPENDENCE; HDR BRACHYTHERAPY; FIBEROPTIC DOSIMETRY; PHOTON BEAMS; RADIATION; RADIOLUMINESCENCE; ACCELERATOR;
D O I
10.1088/0031-9155/61/21/7744
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We tested the potential of ruby inorganic scintillation detectors (ISDs) for use in brachytherapy and investigated various unwanted luminescence properties that may compromise their accuracy. The ISDs were composed of a ruby crystal coupled to a poly(methyl methacrylate) fiber-optic cable and a charge-coupled device camera. The ISD also included a long-pass filter that was sandwiched between the ruby crystal and the fiber-optic cable. The long-pass filter prevented the Cerenkov and fluorescence background light (stem signal) induced in the fiber-optic cable from striking the ruby crystal, which generates unwanted photoluminescence rather than the desired radioluminescence. The relative contributions of the radioluminescence signal and the stem signal were quantified by exposing the ruby detectors to a high-dose-rate brachytherapy source. The photoluminescence signal was quantified by irradiating the fiber-optic cable with the detector volume shielded. Other experiments addressed time-dependent luminescence properties and compared the ISDs to commonly used organic scintillator detectors (BCF-12, BCF-60). When the brachytherapy source dwelled 0.5 cm away from the fiber-optic cable, the unwanted photoluminescence was reduced from >5% to <1% of the total signal as long as the ISD incorporated the long-pass filter. The stem signal was suppressed with a band-pass filter and was <3% as long as the source distance from the scintillator was <7 cm. Some ruby crystals exhibited time-dependent luminescence properties that altered the ruby signal by >5% within 10 s from the onset of irradiation and after the source had retracted. The ruby-based ISDs generated signals of up to 20 times that of BCF-12-based detectors. The study presents solutions to unwanted luminescence properties of ruby-based ISDs for high-dose-rate brachytherapy. An optic filter should be sandwiched between the ruby crystal and the fiber-optic cable to suppress the photoluminescence. Furthermore, we recommend avoiding ruby crystals that exhibit significant time-dependent luminescence.
引用
收藏
页码:7744 / 7764
页数:21
相关论文
共 42 条
[1]   Fiber-coupled radioluminescence dosimetry with saturated Al2O3:C crystals: Characterization in 6 and 18 MV photon beams [J].
Andersen, C. E. ;
Damkjaer, S. M. S. ;
Kertzscher, G. ;
Greilich, S. ;
Aznar, M. C. .
RADIATION MEASUREMENTS, 2011, 46 (10) :1090-1098
[2]   Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy [J].
Andersen, Claus E. ;
Nielsen, Soren Kynde ;
Lindegaard, Jacob Christian ;
Tanderup, Kari .
MEDICAL PHYSICS, 2009, 36 (11) :5033-5043
[3]  
[Anonymous], SCINTILLATION PROPER
[4]   Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator [J].
Archambault, Louis ;
Briere, Tina Marie ;
Beddar, Sam .
MEDICAL PHYSICS, 2008, 35 (10) :4342-4351
[5]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[6]   CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[7]   On possible temperature dependence of plastic scintillator response [J].
Beddar, Sam .
MEDICAL PHYSICS, 2012, 39 (10) :6522-6522
[8]  
Bessonova T. S., 1977, Zhurnal Prikladnoi Spektroskopii, V27, P238
[9]  
Bessonova T S, 1980, VESTN MOSKOVKOGO U F, V35, P63
[10]  
Bessonova T S, 1979, ZH PRIKL SPEKTROSK, V30, P829