INFLUENCE OF HIGH INITIAL ISOLATOR STIFFNESS ON THE SEISMIC RESPONSE OF A BASE-ISOLATED BENCHMARK BUILDING

被引:13
作者
Sharma, Ajay [1 ]
Jangid, R. S. [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
关键词
Base isolation; benchmark building; earthquake; initial isolator stiffness; stiffness ratio; characteristic strength; SEMIACTIVE CONTROL; CONTROL-SYSTEMS; BRIDGES; MOTIONS;
D O I
10.1142/S0219455411004543
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influence of high initial isolator stiffness on the response of a base-isolated benchmark building is investigated. The base-isolated building is modeled as a three-dimensional linear-elastic structure having three degrees-of-freedom at each floor level. The time-history analysis of this building is carried out by solving the governing equations of motion using Newmark-beta method along with an iterative predictor-corrector approach. The force-deformation behavior of the isolation system is modeled by a bilinear law, which can be effectively used to model all isolation systems in practice. Three near-field earthquakes with bidirectional ground motions are considered. Structural response parameters such as absolute top floor acceleration, base shear, and base displacement are chosen for investigating the effects of high initial isolator stiffness. It was observed that the high initial isolator stiffness of the isolation system excites the higher modes in the base-isolated building and increases the top floor acceleration. Such a phenomenon can be detrimental to the sensitive instruments placed in the isolated structure. On the other hand, both the base displacement and base shear reduce marginally due to increase in the initial isolator stiffness. Further, the influences of high initial isolator stiffness are found to dependent on the period and characteristic strengths of the base isolation system.
引用
收藏
页码:1201 / 1228
页数:28
相关论文
共 26 条
[1]  
Buckle I.G., 1990, Earthquake Spectra, V6, P161, DOI DOI 10.1193/1.1585564
[2]  
DISARNO L, 2007, 10 WORLD C SEISM IS
[3]   Smart base-isolated benchmark building Part III: A sample controller for bilinear isolation [J].
Erkus, Baris ;
Johnson, Erik A. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3) :605-625
[4]  
Hall J. F., 1995, Earthq. Spectra, V11, P569, DOI DOI 10.1193/1.1585828
[5]  
HALL JF, 1995, SCIENCE, V67, P206
[6]   SEISMIC BEHAVIOR OF BASE-ISOLATED BUILDINGS - A STATE-OF-THE-ART REVIEW [J].
JANGID, RS ;
DATTA, TK .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1995, 110 (02) :186-203
[7]   Base isolation for near-fault motions [J].
Jangid, RS ;
Kelly, JM .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (05) :691-707
[8]  
Kelly J.M., 1986, SOIL DYN EARTHQ ENG, V5, P202
[9]  
Kelly J.M., 1993, Earthquake-resistant design with rubber
[10]   Seismic behaviour of asymmetric base isolated structures with various distributions of isolators [J].
Kilar, Vojko ;
Koren, David .
ENGINEERING STRUCTURES, 2009, 31 (04) :910-921