Cyclic loading of periprosthetic fracture fixation constructs

被引:70
作者
Talbot, Max [3 ]
Zdero, Radovan [1 ]
Schemitsch, Emil H. [2 ]
机构
[1] 1 Canadian Field Hosp, Martin Orthopaed Biomech Lab, Toronto, ON, Canada
[2] St Michaels Hosp, Dept Orthopaed, Toronto, ON M5B 1W8, Canada
[3] Canadian Forces, Toronto, ON, Canada
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 64卷 / 05期
关键词
periprosthetic fracture; locking plates; biomechanics; allograft struts;
D O I
10.1097/TA.0b013e31811ea244
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Femur fractures are a common complication of hip arthroplasty. When the stem is well fixed, fracture fixation is the preferred treatment option. Numerous fixation methods have been advocated, using plates or allograft struts. Methods: Vancouver type B1 periprosthetic femur fractures were created distal to a cemented hip stem in 15 third-generation composite femurs. The fractures were fixed with (1) a nonlocking plate and allograft strut, (2) a locking plate and allograft strut, or (3) a locking plate alone. The struts were fixed with cables. After fixation, the constructs underwent cyclic loading for 100,000 cycles. Stiffness of the constructs was determined during bending, torsion, and axial compression before and after cyclic loading. Load to failure was also determined. Results: Overall, cyclic loading had little effect on the mechanical properties of these constructs. The two constructs with allografts were significantly stiffer in bending than the construct consisting of only a locking plate. There were no significant differences in axial or torsional stiffness between the constructs. Load to failure of the two constructs with allografts was significantly greater than the locking plate alone. Conclusions: Allograft strut-plate constructs are stiffer in bending and have a higher load to failure than a stand-alone locking plate. When an allograft plate construct is chosen, locking screw seemed to provide no mechanical advantage. All three constructs tested retained their mechanical characteristics after 100,000 cycles of loading. Our initial concern that the cables fixing the allograft strut would loosen appears unfounded.
引用
收藏
页码:1308 / 1312
页数:5
相关论文
共 17 条
  • [1] Percutaneous plate fixation for periprosthetic femoral fractures - a preliminary report
    Abhaykumar, S
    Elliott, DS
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (08): : 627 - 630
  • [2] Epidemiology - Hip and knee
    Berry, DJ
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) : 183 - +
  • [3] Classification of the hip
    Brady, OH
    Garbuz, DS
    Masri, BA
    Duncan, CP
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) : 215 - +
  • [4] Mechanical validation of whole bone composite femur models
    Cristofolini, L
    Viceconti, M
    Cappello, A
    Toni, A
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 525 - 535
  • [5] Nonunion after periprosthetic femoral fracture associated with total hip arthroplasty
    Crockarell, JR
    Berry, DJ
    Lewallen, DG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (08) : 1073 - 1079
  • [6] Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques
    Dennis, MG
    Simon, JA
    Kummer, FJ
    Koval, KJ
    Di Cesare, PE
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) : 177 - 180
  • [7] Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques
    Dennis, MG
    Simon, JA
    Kummer, FJ
    Koval, KJ
    DiCesare, PE
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (04) : 523 - 528
  • [8] Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems - A biomechanical comparison of locked plating and conventional cable plates
    Fulkerson, E
    Koval, K
    Preston, CF
    Iesaka, K
    Kummer, FJ
    Egol, KA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (02) : 89 - 93
  • [9] Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate
    Haddad, FS
    Duncan, CP
    Berry, DJ
    Lewallen, DG
    Gross, AE
    Chandler, HP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06) : 945 - 950
  • [10] Structural properties of a new design of composite replicate femurs and tibias
    Heiner, AD
    Brown, TD
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (06) : 773 - 781