Thermal Hydraulic Performance in a Solar Air Heater Channel with Multi V-Type Perforated Baffles

被引:39
作者
Kumar, Anil [1 ]
Kim, Man-Hoe [1 ]
机构
[1] Kyungpook Natl Univ, Sch Mech Engn, Daegu 41566, South Korea
来源
ENERGIES | 2016年 / 9卷 / 07期
关键词
solar energy; heat transfer enhancement; friction factor; solar air heater (SAH) channel; perforated baffle; TRANSFER ENHANCEMENT; FLOW CHARACTERISTICS; RIB ROUGHNESS; FLUID-FLOW; DUCT; PLATE;
D O I
10.3390/en9070564
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article presents heat transfer and fluid flow characteristics in a solar air heater (SAH) channel with multi V-type perforated baffles. The flow passage has an aspect ratio of 10. The relative baffle height, relative pitch, relative baffle hole position, flow attack angle, and baffle open area ratio are 0.6, 8.0, 0.42, 60 degrees, and 12%, respectively. The Reynolds numbers considered in the study was in the range of 3000-10,000. The re-normalization group (RNG) k-epsilon turbulence model has been used for numerical analysis, and the optimum relative baffle width has been investigated considering relative baffle widths of 1.0-7.0.The numerical results are in good agreement with the experimental data for the range considered in the study. Multi V-type perforated baffles are shown to have better thermal performance as compared to other baffle shapes in a rectangular passage. The overall thermal hydraulic performance shows the maximum value at the relative baffle width of 5.0.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Review on the design modifications of a solar air heater for improvement in the thermal performance
    Arunkumar, H. S.
    Karanth, K. Vasudeva
    Kumar, Shiva
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 39
  • [42] Experimental study on thermo-hydraulic performance of a solar air heater with rectangular perforated duct inserts
    Arunkumar, H. S.
    Kumar, Shiva
    Karanth, K. Vasudeva
    SOLAR ENERGY, 2021, 227 : 179 - 189
  • [43] Hydrothermal performance of humid air flow in a rectangular solar air heater equipped with V-shaped ribs
    Kadijani, Omid Nouri
    Moghadam, Hamid Kazemi
    Ajarostaghi, Seyed Soheil Mousavi
    Asadi, Asgar
    Pour, Mohsen Saffari
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (07) : 2276 - 2289
  • [44] A comparative analysis of thermo-hydraulic performance of a roughened solar air heater using various rib shapes
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Mangrulkar, Chidanand
    AUSTRALIAN JOURNAL OF MECHANICAL ENGINEERING, 2020, 18 (03) : 331 - 350
  • [45] Numerical investigation of the effect of using louver baffles on thermal performance in solar air collectors
    Tugan, Volkan
    Isik, Erdem
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2023, 42 (05)
  • [46] Thermal performance improvement of a solar air heater fitted with winglet vortex generators
    Chamoli, Sunil
    Lu, Ruixin
    Xu, Dehao
    Yu, Peng
    SOLAR ENERGY, 2018, 159 : 966 - 983
  • [47] Flow friction and thermal performance of dimple imprinted based solar air-heater: A numerical study
    Panda, Sudharani
    Kumar, Rakesh
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2023, 84 (01) : 35 - 53
  • [48] Analysis of the effect of variation in open area ratio in perforated multi-V rib roughened single pass solar air heater- Part A
    Singh, Varun Pratap
    Jain, Siddharth
    Gupta, J. M. L.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022,
  • [49] Thermal characteristic in solar air heater fitted with plate baffles and heating corrugated surface
    Sahel, Djamel
    Benzeguir, Redouane
    MATERIALS & ENERGY I (2015) / MATERIALS & ENERGY II (2016), 2017, 139 : 307 - 314
  • [50] Enhancing the performance of a solar air heater by employing the broken V-shaped ribs
    Rajendran, Vijayakumar
    Vikram, Muthuraman Ponrajan
    Kim, Sung Chul
    Gullo, Paride
    Alodhayb, Abdullah
    Pandiaraj, Saravanan
    Prabakaran, Rajendran
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (31) : 77807 - 77818