Failure Analysis of Medical Devices

被引:5
作者
Bowers, Matthew [1 ]
Ganot, Gabriel [1 ]
Malito, Louis [1 ]
Kondori, Babak [2 ]
Ezechukwu, Anyanwu [1 ]
Svedlund, Felicia [1 ]
James, Brad [1 ]
机构
[1] Exponent Inc, Menlo Pk, CA 94025 USA
[2] Exponent Inc, SpaceX, Hawthorne, CA USA
关键词
Bone plates; Bone screws; Cardiovascular implants; Corrosion; Failure analysis; Fracture; Orthopedic implants; Surgical tools; Wear; TOTAL HIP-REPLACEMENT; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; FRETTING CORROSION; FEMORAL PROSTHESIS; STAINLESS-STEEL; FRACTURE; FATIGUE; TAPER; IMPACT; PACEMAKER;
D O I
10.1007/s11668-021-01332-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bearing in mind the three-legged stool approach of device design/manufacturing, patient factors, and surgical technique, this article aims to inform the failure analyst of the metallurgical and materials engineering aspects of a medical device failure investigation. It focuses on the device "failures" that include fracture, wear, and corrosion. The article first discusses failure modes of long-term orthopedic and cardiovascular implants. The article then focuses on short-term implants, typically bone screws and plates. Lastly, failure modes of surgical tools are discussed. The conclusion of this article presents several case studies illustrating the various failure modes discussed throughout.
引用
收藏
页码:154 / 180
页数:27
相关论文
共 92 条
  • [11] Finite element analysis of hip stem designs
    Bennett, David
    Goswami, Tarun
    [J]. MATERIALS & DESIGN, 2008, 29 (01) : 45 - 60
  • [12] BOBYN JD, 1994, CLIN ORTHOP RELAT R, P27
  • [13] INFLUENCE OF FLUORIDE ON TITANIUM IN AN ACIDIC ENVIRONMENT MEASURED BY POLARIZATION RESISTANCE TECHNIQUE
    BOERE, G
    [J]. JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (04) : 283 - 288
  • [14] Pacemaker and ICD leads: Strategies for long-term management
    Borek, P. Peter
    Wilkoff, Bruce L.
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (01) : 59 - 72
  • [15] Fractures of distally-fixed femoral stems after revision arthroplasty
    Busch, CA
    Charles, MN
    Bourne, RB
    Rorabeck, CH
    MacDonald, SJ
    McCalden, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (10): : 1333 - 1336
  • [16] Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation
    Buttaro, Martin A.
    Mayor, Michael B.
    Van Citters, Douglas
    Piccaluga, Francisco
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (05) : 780 - 783
  • [17] CALLAGHAN JJ, 1988, ORTHOP CLIN N AM, V19, P637
  • [18] FRACTURE OF FEMORAL PROSTHESIS IN TOTAL HIP-REPLACEMENT ACCORDING TO CHARNLEY
    CARLSSON, AS
    GENTZ, CF
    STENPORT, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (06): : 650 - 655
  • [19] Evaluation of the fretting corrosion behavior of the proximal pad taper of a modular hip design
    Chandrasekaran, V
    Sauer, WL
    Taylor, AM
    Hoeppner, DW
    [J]. WEAR, 1999, 231 (01) : 54 - 64
  • [20] Cheng M., 2003, MED DEVICE REGULATIO, P3